Renco PREG-ALERT PRO Instruction Manual Download Page 2

PREG

ALERT

 

PRO

®

 

INSTRUCTION

 

MANUAL

  

Rev.

 

2

     

7/1/2007

 

©2007

 

Renco

 

Corporation

  

 

Page

 

2

 

of

 

13

 

 
 

For

 

clarity

 

and

 

uniformity,

 

we

 

have

 

given

 

all

 

metric

 

measurement

 

in

 

millimeters

 

(mm),

 

even

 

though

 

in

 

some

 

cases

 

the

 

common

 

practice

 

may

 

be

 

to

 

use

 

centimeters

 

(cm).

  

To

 

convert

 

to

 

cm,

 

divide

 

millimeters

 

by

 

10.

  

For

 

the

 

same

 

reasons

 

we

 

have

 

omitted

 

inch

 

conversions

 

in

 

many

 

cases.

 

To

 

convert

 

mm

 

to

 

inches,

 

divide

 

mm

 

by

 

25.4

 

or

 

multiply

 

by

 

.04.

  

Note

 

that

 

In

 

all

 

cases

 

and

 

for

 

all

 

readings,

 

measurements

 

can

 

be

 

indicated

 

in

 

either

 

mm

 

or

 

inches.

   

 

QUICK

 

START

 

CONTROLS

 

AND

 

FUNCTIONS

 

ON/HOLD

 

OFF:

 

Press

 

to

 

turn

 

instrument

 

on.

 

To

 

turn

 

on

 

with

 

backlight,

 

hold

 

key

 

for

 

2

 

seconds.

  

When

 

reading

 

is

 

displayed,

 

press

 

ON/HOLD

 

to

 

maintain

 

it.

 

Pressing

 

again

 

releases

 

the

 

HOLD.

 

Instrument

 

automatically

 

turns

 

off

 

if

 

there

 

is

 

no

 

use

 

for

 

3.5

 

minutes.

 

 

SENS

 

Keys

 

Selects

 

sensitivity

 

1(least)

 

through

 

4

 

(greatest),

 

which

 

is

 

displayed

 

on

 

the

 

screen.

  

Use

 

the

 

lowest

 

setting

 

that

 

gives

 

a

 

result.

 

 

Using

 

too

 

high

 

a

 

setting

 

could

 

give

 

spurious

 

results.

   

 

DEPTH

 

Keys

 

The

 

DEPTH

 

Keys

 

control

 

the

 

position

 

of

 

a

 

vertical

 

dashed

 

marker

 

on

 

each

 

screen.

  

Adjust

 

to

 

depth

 

of

 

interest

 

using

 

right

 

and

 

left

 

arrow

 

keys.

  

This

 

marker

 

is

 

calibrated

 

and

 

the

 

distance

 

is

 

displayed

 

on

 

the

 

right

 

side

 

of

 

the

 

screen

 

 

In

 

these

 

Instructions,

 

scales

 

at

 

the

 

bottom

 

of

 

the

 

various

 

illustration

 

screens

 

are

 

evenly

 

divided.

  

Minor

 

divisions

 

are

 

not

 

shown

 

on

 

the

 

graphics

 

here

 

to

 

avoid

 

clutter.

   

 

PREGNANCY

 

SCREENS

:

 

The

 

vertical

 

marker

 

displays

 

the

 

distance

 

to

 

a

 

spike

 

of

 

interest.

 

To

 

change

 

from

 

mm

 

to

 

inches,

 

go

 

to

 

the

 

fat

 

screen

 

and

 

press

 

the

 

OPTION

 

key.

 

COW

:

  

Left

 

Major

 

Division:

 

101mm

 

(4

 

in)

  

Right

 

Major

 

Division:

 

338mm

 

(13.5

 

in)

 

PIG

:

 

51

288mm

 

(2

11.5

 

in)

 

SHEEP:

 

51

288mm

 

(2

11.5

 

in)

 

OTHER:

 

51

209mm

 

(2

8.3

 

in).

  

(This

 

screen

 

is

 

for

 

small

 

&

 

medium

 

mammals.

  

Use

 

COW

 

for

 

large

 

mammals.)

 

 

FAT

 

Screen:

   

Range:

 

3mm

 

to

 

42mm

 

(.12

1.65in)

 

OPTION

 

key

 

selects

 

units,

 

mm

 

or

 

in.

 

LOIN

 

Screens:

 

Use

 

OPTION

 

Key

 

to

 

select

 

low

 

or

 

high

 

range:

 

50mm

140mm

 

(2

5.6in)

  

or

 

90

180mm

 

(3.6

7.2in).

 

For

 

the

 

FAT

 

and

 

LOIN

 

screens,

 

spikes

 

that

 

occur

 

to

 

right

 

of

 

the

 

vertical

 

marker

 

position

 

will

 

be

 

suppressed,

 

which

 

helps

 

to

 

further

 

refine

 

the

 

display.

 

 
 

SELECT

 

Key:

 

FAT:

    

Display

 

range

 

is

 

3

42mm.

 

Use

 

OPTION

 

key

 

to

 

select

 

in.

 

or

 

mm.

  

NOTE:

 

In

 

order

 

to

 

switch

 

measurement

 

system

 

with

 

the

 

OPTION

 

key,

 

the

 

FAT

 

screen

 

한국대리점: 길우트레이딩 02)2636-0009 팩스02)2636-4753   서울시 영등포구 양평동 3가 40-2 에이스테크노타워703호    [email protected]    www.gilwoo.co.kr

Summary of Contents for PREG-ALERT PRO

Page 1: ...PREG ALERT PRO INSTRUCTIONS Rev 2 02 2636 0009 02 2636 4753 3 40 2 703 giltron chol com www gilwoo co kr...

Page 2: ...d marker on each screen Adjust to depth of interest using right and left arrow keys This marker is calibrated and the distance is displayed on the right side of the screen In these Instructions scales...

Page 3: ...that were generated by the ultrasonic pulses emitted by the transducer also called the probe Sound travels at different speeds through fat and muscle The instrument uses the appropriate speed for eac...

Page 4: ...ment Select the FAT screen Most backfat testing in swine for example is done over the last rib and 40 60mm off the center line called the P2 test site This test site is also important for making the s...

Page 5: ...use the important thing to look for is a strong high spike or group of spikes in the area of interest as displayed on the screen Pregnancy can be determined either by sensing the fetus or the interfa...

Page 6: ...g to identify very early pregnancy then since the reading is at the left end of the black bar it would probably be indicating a thickened uterine wall The Deep probe would be used for this In actual u...

Page 7: ...nd mares testing should be started on the left side If no pregnancy is detected then try the other side in all cases but be cautious of the results in ruminate animals where the rumen might interfere...

Page 8: ...ting swine on right side and if not pregnant try again on the left side Testing can begin at 18 days testing every day until positive readings are obtained 2 days in a row Accuracy is greatest at 30 d...

Page 9: ...35 days Test on left side if not successful It may be necessary to remove wool and dirt from test site Pregnancy Test Site for Alpacas Begin testing alpacas on the LEFT side at about 45 days Test on...

Page 10: ...iangular region forward of the hook bone just behind the ribs and about 8 inches 20cm down from the backbone Locate the lowest spot in the fossa into which the probe will fit comfortably by pressing i...

Page 11: ...MANUAL Rev 2 7 1 2007 Pregnancy Test Site Mares Side View Pregnancy Test Site for Mares Left Side View Right Back View 2007 Renco Corporation Page 11 of 13 02 2636 0009 02 2636 4753 3 40 2 703 giltron...

Page 12: ...ation progresses you should move the probe downwards within the area shown by the outline in the side view Side View Position 2 is for use after approximately 90 100 days and the Standard probe may be...

Page 13: ...x 612 333 9026 Email TechSupport Rencocorp com Internet http www rencocorp com CAUTION DO NOT USE THE PREG ALERT PRO ON HUMAN BEINGS CERTIFICATION AND COMPLIANCE FCC Required 15 21 Information to User...