G
EN
ER
A
L
S
PE
CIF
ICA
TI
O
N
S
9
Table 1 Unit Clearances and Specifications
A Distance to combustible material from side, back and top
standoffs
0" (0.0 mm)
B Minimum distance from side wall to the side of the
fireplace opening
24" (610 mm)
C
Minimum ceiling clearance: Always take measurement
from the lowest point on the fireplace
When the bottom standoff is not being used,
measure from the base of the fireplace to the ceiling
When the bottom standoff is installed, measure from
the base of the bottom standoff to the ceiling
(refer to the "INSTALLATION: Flooring Requirements"
section for details)
8' (2.44 m)
D Minimum chimney height: minimum total chimney height
from fireplace top to below the chimney rain cap
12' (3.66 m)
E Maximum chimney height: maximum total chimney
height from fireplace top to below the chimney rain cap
60' (18.3 m)
F Maximum chimney height supported by the fireplace
15' (4.57 m)
G
Minimum depth of non-combustible hearth extension:
from the front of the fireplace (refer to the
"INSTALLATION: Hearth Extension" section for details)
24" (610 mm)
H
Minimum width of non-combustible hearth extension:
total width, must be centered on the firebox opening
(refer to the "INSTALLATION: Hearth Extension" section
for details)
67" (1.70 m)
I Minimum width of the spark guard
67" (1.70 m)
J Maximum mantel shelf depth (see Table 2 for other
mantel sizes)
12" (305 mm)
K
Minimum height of a combustible mantel shelf above the
top of the fireplace opening (to the bottom of the
combustible mantel) (refer to the "INSTALLATION:
Mantel" section for details)
See Table 2
L Maximum mantel post depth (see Table 3 for other
mantel post sizes)
12" (305 mm)
M
Minimum distance between each combustible mantel post
and the fireplace opening (refer to the "INSTALLATION:
Mantel" section for details)
See Table 3