![Renac ESC3000-DS Manual Download Page 21](http://html1.mh-extra.com/html/renac/esc3000-ds/esc3000-ds_manual_1439510021.webp)
21
Connection Step:
Disconnect the DC switch.
Choose 12 AWG wire to connect the PV module.
Trip 6mm of insulation from the Wire end.
Separate the DC connector.
Insert striped cable into pin contact and ensure all conductor strands are captured in the
pin contact.
Crimp pin contact by using a crimping pliers. Put the pin contact with striped cable into the
corresponding crimping pliers and crimp the contact.
Insert pin contact through the cable nut to assemble into back of the male or female plug.
When you feel or heard a
“click” the pin contact assembly is seated correctly.
Tight the DC connector.
a. Slide the cable nut towards the back shell.
b. Rotate the cable nut to secure the cable.
After securing the cable tightly, align the 2 half connectors and mate them. together by
hand until a
“click” is felt or heard.
Separate the DC connector
a. Use he specified wrench tool.
b. When separate the DC+ connector, push the tool down from upside.
c. When separate the DC- connector, push tool down from the bottom side.
d. Separate the connectors by hands.
WARNING!
Before connecting, disconnecting the connection between solar generator and
inverter and locked it to the open position during installation. Place a warning
sign
”do not turn on maintenance in progress” on the external disconnect switch
when it is shut down, and make sure that on-off remote controls are inhibited.
Summary of Contents for ESC3000-DS
Page 1: ...1...
Page 46: ...46 P N 422 00029 02...