Possible Reason
Troubleshooting
(1). RxQual of donor signal is originally bad.
(2). Adjacent-channels or Co-channels were
introduced by the repeater system.
(3). Self-oscillation occurs.
(4). Too many BCCH channels were
introduced. (Frequent handover may
downgrade the signal quality).
(1). Re-orientate or re-locate donor ant. in order to find
another donor signal. The alternative way is to contact
the engineer of operator to fix the BTS problem.
(2). Re-orientate or re-locate donor ant. and try to increase
the ratio C/A or C/I (To let the major signal as stronger
as possible, and make the adjacent-channel or co-
channel signals as weaker as possible).
(3). Isolation is possibly insufficient, and the alarm of “AGC”
(Over AGC range) shall light. Try to increase the
separation between service ant. and donor ant. (It’s a
little difficult for complicated DAS indoors).
(4). Re-orientate or re-locate donor antenna in order to
introduce one major BCCH (The major BCCH must be
6 dB higher than its 1
st
strongest neighbor).
Q2: Poor speech quality in the coverage area
Troubleshooting
Summary of Contents for RP12 WCDMA
Page 3: ...2010 Company Confidential 3 Product Overview...
Page 6: ...2010 Company Confidential 6...
Page 10: ...2010 Company Confidential 10 Installation Wall Mounted Application...
Page 11: ...2010 Company Confidential 11 Connection Application...
Page 12: ...2010 Company Confidential 12 Heat Sink Application...
Page 19: ...2010 Company Confidential 19 R19 System Design Technical Proposal Site Survey Report Example...
Page 20: ...2010 Company Confidential 20 System Design Technical Proposal Site Survey Report Example...
Page 21: ...2010 Company Confidential 21 Technical Proposal Site Survey Report Example System Design...