Z-Wave setup and operations 

 

Include/Exclude ZRP-120 to/from a Z-Wave Gateway 

Include or Exclude the ZRP-120 from the existing Z-Wave Home Control Network with 

your primary controller. 

-

 

Refer to your primary controller instructions to process the inclusion / exclusion 

setup procedure. 

-

 

When prompted by your primary controller, triple click the PROG button within 1 

second. 

-

 

The primary controller should indicate that the action was successful. If the 

controller indicates the action was unsuccessful, please repeat the procedure. 

 

Notes: 

1, It is recommended to perform the Remove (Exclude) procedure before performing an Add 

(Include) procedure.   

2, The unit will enter classical inclusion/exclusion first, then jump to NWI, and after 20 

seconds, it will finally exit NWI mode automatically if there is no inclusion/exclusion 

request.) 

3, ZRP-120 will not support Basic Command Class 

4, All configuration parameters value will keep no change after exclude the unit from network   

5, ZRP-120 can be included and operated in any Z-Wave network with other Z-Wave certified 

devices from other manufacturers and/or other applications. 

 

The Below listed Command Class are all supported the Security S2   

COMMAND_CLASS_ASSOCIATION 

COMMAND_CLASS_ASSOCIATION_GRP_INFO 

COMMAND_CLASS_DEVICE_RESET_LOCALLY 

COMMAND_CLASS_MANUFACTURER_SPECIFIC   

COMMAND_CLASS_POWERLEVEL 

COMMAND_CLASS_SUPERVISION 

COMMAND_CLASS_VERSION 

 
 

LED Indication Status 

Operations 

LED Indication Status 

Device not currently paired into 
a Z-Wave network 

LED will continuously flash two times per second. 

Learning / NWI mode:

 

Triple click on PROG button

 

 

If the device already existing in the network, LED will flash slowly 
for 20 seconds, and then return to previous ON or OFF stage. 
If the device does not exist in the network, LED will keep flash 
slowly and waiting for Network Wide Inclusion (NWI) 
(The device will exit NWI mode automatically after 20 seconds) 

Summary of Contents for ZRP-120NA

Page 1: ...performance to replicate Z Wave signals in a network The repeater re transmits an input Radio Frequency RF signal by routing the signal around obstacles and radio dead spots to ensure that the signal...

Page 2: ...controllers operating on the same system A Z Wave network has its own unique ID code so that controllers not in the network cannot control the system Primary Controller The first controller is used to...

Page 3: ...To avoid fire shock or death turn off power at circuit breaker or fuse and test that power is off before dismount or mount the unit with the screw In case that the user needs to mount the unit with sc...

Page 4: ...lower outlet when plugged into upper outlet of a duplex wall receptacle and vice versa Possible configurations are illustrated below Un grounded AC outlet with center screw Grounded AC outlet with ce...

Page 5: ...support Basic Command Class 4 All configuration parameters value will keep no change after exclude the unit from network 5 ZRP 120 can be included and operated in any Z Wave network with other Z Wave...

Page 6: ...ntly deleted Please use this procedure only when the network primary controller is missing or otherwise inoperable Support for Association Groups ZRP 120 supports 1 association group Association Group...

Page 7: ...e or abrasive cleansers on your unit 3 Keep the unit dust free by wiping it with a soft dry cloth 4 Do not disassemble your unit it contains no user serviceable parts Technical Specifications Model no...

Page 8: ...ermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the s...

Page 9: ...devices for indirect incidental special consequential or punitive damages including inter alia loss of profits savings data loss of benefits claims by third parties and any property damage or persona...

Reviews: