background image

WIRING THE OMEGA-10 ESC 

by FOSWORKS.

SIDE VIEW OF # AB-EM RX.  

SERVO PLUG

YELLOW/WHITE SIGNAL

BLACK (NEGATIVE)

RED (POSITIVE)

Motor out +

Motor out -

Ne
g

a

tiv
e   -

P

ow
er IN

. +

PAY PARTICULAR ATTENTION TO WIRING 

THE ESC DIRECTIONAL LIGHTS.

RED

BLACK

LED

POWER OUT

TO THROTTLE

& ACCESSORIES.

RED

BLACK

BATTERY
CONNECTION

FUSES

One Orange Polyswitch mean a 3 amp version
Two orange Polyswitches means a 6 amp version.

OFF - ON

White

Front LED

The LED’s require current limiting

resistors be fitted in line.

Rear LED

BLUE BATTERY voltage wire goes to long legs of LED’s

Yellow

HOW TO CONNECT BASIC POWER & LIGHTS.

Match light bulbs with

the traction battery voltage. 

Rear Bulb

Yellow

White

Red +

Front Bulb

WHITE & YELLOW WIRES

GO TO FRONT & REAR ON THE ESC

RED WIRE

GOES TO B

OMEG

A-10

When adding other features such as triggering sound systems, information and wiring examples will be 
provided with the add on’s chosen.

©

©

Use the lighting outputs to control a 

# RELAY-1v3

 for easy wiring of USAT  and LGB  locos.  

©

©

Use the simple 

# PnP-BATT

 kit for Aristo Craft  and Bachmann  locos fitted wth PnP sockets.

A suitable fuse must be used for system protection. A 5 amp fast blow fuse should be used for most locos. 

©

RCS installation kits are fitted with Polyswitch  solid state auto reset fuses.
Do not exceed 7 amps without checking with us. 

# OMEGA-10

 for use up to 50 watts. 

JST connectors are also available. 

470R

470R

THRO 1

2

DIRECTION 3

4

5

6

B

A

T/BIND

SERVO LEADS FROM ESC

THREE WIRE W/WHITE TRACE SETS DIRECTION. 

SINGLE WHITE WIRE CONTROLS SPEED.

R

ear

F

ront

0v   -

Ba

tt +

SERVO PLUG

SIDE VIEW OF # AB-TM RX

YELLOW/WHITE/ORANGE (SIGNAL)

BLACK (NEGATIVE)

RED (POSITIVE)

 

AB-TM

6ch RX v2.

TOP

Three wire cable. Ensure plugs are correctly located.

 wire towards top - inwards of  RX.

Orange/White

Dual 20cm 

Diversity Antennas

Summary of Contents for AB-TM

Page 1: ...s only the last 31 mm of the 20 cm antenna that actually receives the incoming signal For maximum range in metal loco it may need to be placed outside the loco OPERATION Mount the Rx so that operation of the bright LED can be observed when binding etc Unless Auto Binding always switch Tx on first then the Rx When operation has finished switch the Loco OFF first then the Rx Ch 1 SERVO REVERSED Ch 1 se...

Page 2: ...NEGATIVE RED POSITIVE SERVO PLUG SIDE VIEW OF AB TM RX YELLOW WHITE ORANGE SIGNAL BLACK NEGATIVE RED POSITIVE Dual 20cm Diversity Antennas AB TM 6ch RX v2 TOP CONNECTING SERVOS FOR AB EM Rx s AB TM Three wire cable Ensure plugs are correctly located wire towards top inwards of RX Orange White To Battery Charger RX BATTERY PACK Min 4 4 volts Max 4 8 volts NOMINAL Use rechargeable cells instead of d...

Page 3: ...REE PINS ON MRW SSLS MATCH WIRE POLARITY White Front LED LED s must have a suitable dropping resistor fitted in either the positive or negative circuit Rear LED BLUE 5 volt wire goes to long legs of LED s Yellow 470R 470R Match light bulbs with the traction battery voltage Rear Bulb Yellow White Red Front Bulb Ch 3 Reverser servo GROUND IS VIA THE SERVO CABLE SIDE VIEW OF AB EM RX SERVO PLUG YELLO...

Page 4: ...he MRW SSSS has been designed specifically to work with the Ch 5 Bind button found on all RCS Tx handpieces Simply plug the servo cable lead into Ch 5 or any spare Ch The OFF position is above 1 5 ms The switch triggers below 1 45 ms No common ground connection is needed as long as sound is powered by the traction batteries MyLOCOSOUND Whistle Horn Bell Horn Guards Whistle Blowdown Brake Air Pump ...

Page 5: ...S into any spare two channels with a centre idle No common ground connection is needed as long as sound is powered by the traction batteries Max 2 amp load on each trigger MyLOCOSOUND Whistle Horn Bell Horn Guards Whistle Blowdown Brake Air Pump Turbo CHUFF TIMER TWO TRIGGERS PER CHANNEL MRW SSTS The MRW SSTS has been designed specifically to work with the RCS EVO TX 20 handpieces They have three ...

Page 6: ...tures such as triggering sound systems information and wiring examples will be provided with the add on s chosen Use the lighting outputs to control a RELAY 1v3 for easy wiring of USAT and LGB locos Use the simple PnP BATT kit for Aristo Craft and Bachmann locos fitted wth PnP sockets A suitable fuse must be used for system protection A 5 amp fast blow fuse should be used for most locos RCS instal...

Page 7: ...NT REAR ON THE 260 RED WIRE GOES TO BATTERY 470R 470R When adding other features such as triggering sound systems information and wiring examples will be provided with the add on s chosen Use the lighting outputs to control a RELAY 1v3 for easy wiring of USAT and LGB locos Use the simple PnP BATT kit for Aristo Craft and Bachmann locos fitted wth PnP sockets A suitable fuse must be used for system...

Page 8: ...round connection is needed as long as sound is powered by the traction batteries Plug MRW SSQS into Ch 2 Ch 4 SOCKET PCB FRONT 12 1 BLACK YELLOW BLUE WHITE LED RED BLACK FUSES One Orange Polyswitch mean a 3 amp version Two orange Polyswitches means a 6 amp version OFF ON BATTERY PACK 12 24 VOLTS MAX NOMINAL Pushbutton used for programming Motor out Motor out Negative Power IN Rear Front v v COBRA ...

Reviews: