REMKO WKF 120 compact Assembly Instruction Manual Download Page 12

Fig. 21: Fix the connection pipes

16.

Installing the side casing.

The two side parts that are included in the

delivery are made of EPP plastic and are

fixed to the two outer corners of the indoor

unit.

Fig. 22: Installing the side casing

17.

Remove the fixing frame from the casing that

you removed (Fig. 12) and feed the 2 m con-

nection cable of the Smart-WP [heat pump]

controller through. Connect the plug to the

operating module of the heat pump.

Fig. 23: Remove the fixing frame

18.

Insert the operating unit from behind into the

provided opening on the front panel as far as

the front sheet.

Fix the operating unit by also inserting the

frame into the opening as far as the Con-

troller.

Fig. 24: Indoor unit with operating unit

19.

After successfully installing the Indoor unit of

the WKF-compact heat pump, the entire

system must be stamped in accordance with

the DIN standard.

During installation, ensure that the dirt trap

that is included in the delivery is installed in

the return flow of the system. Box of acces-

sories (EDP 260008).

All installation tasks that are to be carried out

to install and operate the system may only be

carried out by authorised personnel with the

required expertise.

All connections that are provided by the cus-

tomer must be installed in accordance with

the applicable standards and directives.

 

 

 

REMKO WKF-compact

 

 

12

Summary of Contents for WKF 120 compact

Page 1: ...Assembly instructions Read the instructions prior to performing any task REMKO WKF compact Inverter heat pump Installation instructions for the technician 0050 2016 06 Edition 1 en_GB ...

Page 2: ...ad these operating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Page 3: ...otes 4 1 5 Safety conscious working 4 1 6 Safety notes for the operator 5 1 7 Safety notes for installation maintenance and inspection 5 1 8 Unauthorised modification and changes 5 1 9 Intended use 5 1 10 Warranty 5 1 11 Environmental protection and recycling 6 1 12 Transport and packaging 6 2 Installing the heat pump 7 3 Unit dimensions for indoor unit 13 4 Spare parts 15 5 Index 16 3 ...

Page 4: ...be fatal or cause serious injury WARNING This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may be fatal or cause serious injury CAUTION This combination of symbol and signal word warns of a potentially hazardous situation which if not avoided may cause injury or mate rial and environmental damage NOTICE This combination of symbol and signal ...

Page 5: ...ls or floors n Mobile units must be set up securely on suit able surfaces and in an upright position Sta tionary units must be permanently installed for operation n The units and components should not be oper ated in areas where there is a heightened risk of damage Observe the minimum clearances n The units and components must be kept at an adequate distance from flammable explosive combustible ab...

Page 6: ... not dis posed in household waste but only in accordance with local regulations and in an environmentally safe manner e g using certified firms and recy cling specialists or at collection points 1 12 Transport and packaging The devices are supplied in a sturdy shipping con tainer or inside the heat pump casing Please check the equipment immediately upon delivery and note any damage or missing part...

Page 7: ...door unit properly in the installation space refer to and carry out the following steps 1 Place the indoor unit and the storage tank as close to each other as possible in the instal lation space Fig 1 Fig 1 Heat pump in delivery state 2 Cut the straps and remove the box and pro tective film Check the indoor units for damage Fig 2 Fig 2 Remove the boxes and the film and check for damage 7 ...

Page 8: ... and right side If necessary loosen the screws by 1 2 turns Fig 4 Fig 4 Remove the sheet metal casing 5 Remove the rear casing frame from the storage tank In the installation space level the storage tank using the adjustment feet Fig 5 Fig 5 Remove the casing frame 6 Screw the numbered corrugated pipes that are included in the delivery into the connec tions that are numbered accordingly on the sto...

Page 9: ...he box of accessories EDP 260008 If the storage tank is still to be operated via a solar plant the lower storage tank probe must also be installed Fig 8 Installation of the immersion probe 8 Unpack the top part of the WKF and place it on a suitable surface Fig 9 Unpacking WKF compact top part 1 Fig 10 Unpacking WKF compact top part 2 9 Remove the front cover Fig 11 Remove front cover 9 ...

Page 10: ...til it is optimally integrated completely into the bottom part of the EPP Now connect the two rear corrugated pipes to the two free connections Closed using a cap in the factory IL HP connection to changeover valve Fig 15 RF HP connection behind the changeover valve NOTICE Use the seals included in the box of accessories A B Fig 14 Install the indoor unit on the storage tank Fig 15 Connecting inle...

Page 11: ...f the storage tank on the front left Fig 20 A and install them upwards through the openings provided for them in the casing cover Fig 20 B Circulation 4 HW outlet 3 CW inlet 5 Use seals If the connection is not used for a circulation it must be properly sealed to the storage tank directly A B 2 1 4 3 Fig 20 Domestic water connection 1 Hot water outlet 2 Circulation 3 Drain valve 4 Cold water inlet...

Page 12: ...s the front sheet Fix the operating unit by also inserting the frame into the opening as far as the Con troller Fig 24 Indoor unit with operating unit 19 After successfully installing the Indoor unit of the WKF compact heat pump the entire system must be stamped in accordance with the DIN standard During installation ensure that the dirt trap that is included in the delivery is installed in the re...

Page 13: ...or indoor units WKF compact Pipe connection arrangement A B 8 2 1 0 1 2 8 8 2 8 2 3 0 3 1 5 3 2 7 8 135 205 142 212 368 384 465 508 50 578 50 267 135 142 212 205 267 368 134 50 164 50 134 50 164 50 384 465 508 50 578 50 7 8 8 2 1 0 1 2 8 8 2 8 2 3 6 5 5 0 2 6 5 3 2 0 3 1 Fig 26 Pipe connection arrangement A WKF B WKF compact 13 ...

Page 14: ...ections A WKF B WKF compact 1 Hot water 2 Circulation 3 Cold water supply 4 Heating inlet 5 Heating return flow 6 Refrigerant liquid pipe 3 8 7 Refrigerant heat gas pipe 5 8 8 2 Heat generator return flow heat pump outlet 9 Safety assembly 10 2 Heat generator inlet heat pump inlet 11 Solar connections REMKO WKF compact 14 ...

Page 15: ...top 1250mm 259050 3 Corrugated tube 4 circ connection on middle 1600mm 259050 4 Corrugated tube 5 KW connection on bottom 2400mm 259050 5 1 x flat gasket for the 3 way valve outside 39mm x inside 27mm x thickness 2mm Material AFM 34 259050 6 10 x flat gasket for the corrugated tubes outside 30mm x inside 21mm x thickness 2mm Material AFM 34 259050 7 When ordering spare parts please state the compu...

Page 16: ...tions 14 Pipe outlets on indoor unit spacing 13 S Safety Dangers of failure to observe the safety notes 4 General 4 Identification of notes 4 Notes for inspection 5 Notes for installation 5 Notes for maintenance 5 Personnel qualifications 4 Safety notes for the operator 5 Safety conscious working 4 Unauthorised modification 5 Unauthorised replacement part manufacture 5 Spare parts 15 W Warranty 5 ...

Page 17: ...17 ...

Page 18: ...REMKO WKF compact 18 ...

Page 19: ......

Page 20: ...ct as advisers to our customers in air conditioning and heating technology SFlbCustomer Service Our equipment operates precisely and reliably However in the event of a fault REMKO customer service is quickly at the scene Our comprehensive network of experienced dealers always guarantees quick and reliable service REMKO INTERNATIONAL and also right in your neighbourhood Make use of our experience a...

Reviews: