background image

27 

Spare Part List VRS B 

No.

 

Description 

VRS 40 

Ref. No. 

VRS 60 

Ref. No. 

VRS 80 

Ref. No. 

VRS 120 

Ref. No. 

VRS 150 

Ref. No. 

VRS 210 

Ref. No. 

VRS 250 

Ref. No. 

VRS 310 

Ref. No. 

VRS 380 

Ref. No. 

VRS 450 

Ref. No. 

1  Lining plate, top

 

1104201  1104202  1104202  1104203  1104204  1104205  1104205  1104206  1104207  1104208 

2  Unit frame, cpl.

 

1104209  1104210  1104211  1104212  1104213  1104214  1104214  1104215  1104216  1104217 

3  Insulation for side lining 

1104218  1104219  1104220  1104221  1104222  1104223  1104223  ————  ————  ———— 

4  Verkleidungsblech, seitl. 

1104227  1104228  1104229  1104230  1104231  1104232  1104232  1104233  1104234  1104235 

5  Comb. chamber cpl. (Standard)

 1104237  1104238  1104239  1104240  1104241  1104242  1104243  1104244  1104245  1104246 

5  Comb. chamber cpl. (Inox) 

1104248  1104249  1104250  1104251  1104252  1104253  1104254  1104255  1104256  1104257

 

6  Air guiding plate, right

 

1104258  1104259  1104260  1104261  1104262  1104263  1104263  1104264  1104265  1104266 

7  Seal comb. chamber flange

 

1104267  1104267  1104267  1104267  1104267  1104268  1104268  1104375  1104375  1104375 

8  Rosette 

1104269  1104269  1104269  1104269  1104269  1104269  1104269  1104269  1104269  1104269

 

9  Screw cap

 

1103219  1103219  1103219  1103219  1103219  1103219  1103219  1103219  1103219  1103219 

10 

Triple combination control

 

1102572  1102572  1102572  1102572  1102572  1102572  1102572  1102572  1102572  1102572 

11  Flue gas brake

 

1102953  1102954  1102955  1102955  1102955  1102957  1102957  1102958  1102958  1102959 

12  Seal for inspection cover 

1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255 

13  Inspection cover, front

 

1104271  1104272  1104272  1104273  1104273  1104274  1104274  1104275  1104276  1104277 

14  Insulation, front/top 

1104279  1104280  1104280  1104281  1104281  1104282  1104282  ————  ————  ————

 

15  Lining plate, front/top 

1104286  1104287  1104287  1104288  1104288  1104289  1104289  1104290  1104291  1104291

 

16  Seal

 

1104292  1104292  1104292  1104292  1104292  1104293  1104293  1103234  1103234  1103234 

17  Burner plate

 

1104294  1104294  1104294  1104294  1104294  1104295  1104295  1103237  1103237  1103237 

18  Lining plate, front/middle 

1104297  1104298  1104298  1104299  1104299  1104300  1104300  1104301  1104302  1104302

 

19  Insulation, front/middle 

1104304  1104305  1104305  1104306  1104306  1104307  1104307  ————  ————  ————

 

20  Blind plate

 

1104311  1104312  1104312  1104313  1104314  1104315  1104315  1104316  1104317  1104317 

21  Belt disc, motor 

dependent on the unit model and compression

 

22  Fan motor 400V / 3~/ N

 

23  V-belt

 

24  Belt disc, fan 

25a Fan 

25b Fan, cpl. (230 V / 1~ / N)

 

dep. on compres.

 

-----------  -----------  -----------  -----------  -----------  -----------  -----------  ----------- 

26  Slotted plate, side

 

1104318  1104319  1104320  1104320  1104321  1104322  1104322  1104322  1104323  1104324 

27  Slotted plate, back

 

1104326  1104327  1104327  1104328  1104329  1104330  1104330  1104331  1104323  1104323 

28  Assembly plate 

dependent on the unit model and compression 

29  Inspection cover, side

 

1104333  1104333  1104333  1104333  1104333  1104334  1104334  1104335  1104336  1104336 

30  Seal for inspection cover

 

1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255 

31  Lining plate, back

 

1104338  1104339  1104340  1104341  1104341  1104342  1104343  1104344  1104345  1104345 

32  Insulation, back 

1104347  1104348  1104349  1104350  1104350  1104351  1104352  ————  ————  ————

 

33  Air guiding plate, left

 

1104356  1104357  1104358  1104359  1104360  1104361  1104361  1104362  1104363  1104364 

34  Exhaust gas connection

 

1104366  1104367  1104368  1104369  1104369  1104370  1104371  1104372  1104373  1104373 

35  Rosette, exhaust connection

 

1103285  1103285  1103286  1103286  1103286  1103287  1103288  1103288  1103289  1103289 

 

 

 

 

 

 

 

 

 

 

 

 

  Not pictured 

 

 

 

 

 

 

 

 

 

 

  Seal for exhaust connection

 

1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255  1103255 

  Control box, cpl. (230 V) 

  Control box, cpl. (400 V) 

  Control box, cpl. ( Y

∆ 

dependent on the unit model and compression 

When ordering spare parts, always specify the unit no.!

 

G

 

The Spare Parts List VRS B applies only for standard model units.

 

G

 

Summary of Contents for VRS 120

Page 1: ...REMKO powerful like a bear REMKO VRS Universal oil gas automatic heaters Edition GB M10 Operation Technology Spare Parts ...

Page 2: ......

Page 3: ...g Diagram 400 V Y Start 20 Wiring Diagram Fan Motor 21 Exploded View VRS 20 INOX 22 Spare Part List VRS 20 INOX 23 Exploded View VRS INOX 24 Spare Part List VRS INOX 25 Exploded View VRS B 26 Spare Part List VRS B 27 Unit Dimensions VRS INOX 28 Unit Dimensions VRS B 28 Read these instructions carefully before setting up operating the unit Our guarantee becomes null and void if the unit is used set...

Page 4: ...for universal fully automatic and smooth operation They are fired directly with heating oil diesel or natural liquid gas The VRS 20 INOX has only been designed for op eration with heating oil or diesel G These units have not been designed for heating private residences or similar spaces G Do not bypass or block safety mechanisms while the unit is in operation Operating Locations of the Units The u...

Page 5: ...p in other rooms if their use requires this e g single heating appliances such as fan heaters and these heating appliances can be safely operated Here the German state building authorities Guidelines for setting up furnaces with a total rated heat output of more than 50 kW in rooms other than heating rooms must be observed The guidelines prohibit erecting furnaces when poten tially dangerous conce...

Page 6: ...ombustion An adequate supply of air for combustion must be en sured by meeting the relevant building requirements Excerpts from the German fire ordinance 1 For furnaces with a total rated heat output of up to 35 kW that are dependent on the air in the room evidence of an adequate air supply for combustion has been provided if the furnaces are set up in a room that has 1 A minimum of one door to th...

Page 7: ...ring capacity Sturdy mounts fixed on the unit are used to attach it In addition the requirements listed in the section Wall As sembly must be observed Outside Setup Units that are set up outside must be adequately pro tected from weather conditions so that they do not have any harmful effects or cause any unreasonable annoy ances during operation The units may only be equipped with armatures and c...

Page 8: ...tion The electrical connection of the units may only be per formed by authorised personnel in accordance with the relevant regulations including any local ones An easily accessible emergency switch must be at tached in the setup room The emergency switch must be protected from unau thorised use Thermostat Connection The room thermostat accessory or day night regulator accessory is connected via sp...

Page 9: ...capacity of the unit and the construction height The dimensions of the exhaust systems must ensure that the exhaust is expelled to the outside regardless of the operating conditions and guarantee that no positive pressure is produced in the rooms These dimensions are based on the cross section and height and to the extent required the heat penetra bility resistance and internal surface The exhaust...

Page 10: ...possible air compression must be checked and appro priate action taken Before Starting Initial operation of the unit and its forced air burner must be performed by the manufacturer or one of its author ised service representatives During this process all regulating control and safety mechanisms must be checked to ensure that they are functioning properly and set correctly Make sure that the fan s ...

Page 11: ...liance with emis sion limits The operator must be informed if defects are found He must then have the unit serviced immediately or its components replaced The following applies Maintenance work on limiting devices self adjusting devices and flame monitoring devices as well as on other safety mechanisms may only be performed by the respective manufacturer or his representatives On the other hand th...

Page 12: ...over 6 and the burner flange Replace them if necessary 7 Service the burner in accordance with the separate operating instructions G Check the burner and all regulating devices to en sure that they are functioning properly and set them to the optimum values Cleaning the Combustion Chamber and the Heat Exchanger of VRS B and VRS INOX Type Units 1 Unplug the unit from the power supply 2 Disassemble ...

Page 13: ...rner malfunction control lamp on the oil firing device is illuminated If so release the relay by pressing the malfunction button The malfunction light goes out and the burner tries to start Keep in mind that some burners have a delayed start due to the oil preheating process for some units G If after the start phase the burner switches off due to a malfunction you may only re release it after wait...

Page 14: ...65 Electrical connection V 230 1 230 1 400 3N 400 3N 400 3N 400 3N 400 3N Frequency Hz 50 50 50 50 50 50 50 Rated current 5 A 2 2 2 6 2 8 3 7 3 7 3 7 5 2 Power consumption 5 kW 0 25 0 25 1 1 1 5 1 5 1 5 2 2 Power consumption 6 kW 0 46 0 46 1 55 1 95 1 95 1 84 2 54 Exhaust gas connection Ø mm 150 150 180 180 200 200 200 Weight 7 kg 150 240 310 360 550 730 820 REMKO VRS 18 16 7 1 050 62 Heating oil ...

Page 15: ... 60 65 Electrical connection 2 V 230 1 230 1 400 3N 400 3N 400 3N 400 3N 400 3N 400 3N 400 3N 400 3N Frequency Hz 50 50 50 50 50 50 50 50 50 50 Rated current 2 5 A 4 5 5 5 2 65 3 6 5 1 6 8 8 8 11 4 8 8 8 8 8 8 8 8 Power consumption 2 5 kW 0 51 0 75 1 1 1 5 2 2 3 0 4 0 5 5 4 0 4 0 4 0 4 0 Power consumption 6 W 210 210 210 450 450 350 350 350 1900 1900 Exhaust gas connection Ø mm 150 150 180 180 180...

Page 16: ...0 12 12 Z 1030 SPZ 2 132 180 72 300 400 50 3 00 6 80 1430 12 12 Z 1145 SPZ 2 125 160 74 410 400 50 3 00 6 80 1430 12 12 Z 1275 SPZ 2 160 180 76 210 80 400 50 3 00 6 80 1430 15 11 Z 750 SPZ 2 118 224 69 150 400 50 4 00 8 80 1435 15 11 Z 835 SPZ 2 106 180 70 270 400 50 5 50 11 40 1450 15 11 Z 945 SPZ 2 132 200 72 370 400 50 5 50 11 40 1450 15 11 Z 1035 SPZ 2 160 224 73 510 400 50 2x 4 0 2x 8 8 1435 ...

Page 17: ...er input KL2 Terminal strip electrical wiring M Fan motor S Operating switch STB Safety temperature limiter TH External thermostat connection TR Temperature control thermostat TW Temperature monitor WS Wieland plug only for factory installed burner An easily accessible emergency switch must be at tached in the setup room but not close to hazardous areas This switch must be protected from damage an...

Page 18: ...serve the right to make modifications in dimensions and construction in the interests of technical progress C Capacitor KB REMKO Triple Combination Control KL Terminal strip in the control box M Fan motor RT Thermostat plug S Operating switch SK Control box STB Safety temperature limiter TR Temperature control thermostat TW Temperature monitor WS Wieland plug Only for factory installed burner Wiel...

Page 19: ...unction lamp fan H2 Operating lamp fan H3 Operating lamp burner H4 Malfunction lamp burner K1 Fan contactor KB REMKO triple combination control M Fan motor RT1 Room thermostat day accessory RT2 Room thermostat night accessory S1 Operating switch STB Safety temperature limiter TR Temperature control thermostat TW Temperature monitor X1 Terminal strip 1 in the control box X2 Terminal strip 2 in the ...

Page 20: ...t to make modifications in dimensions and construction in the interests of technical progress red opt Running hour meter red white white Heat Fan Off red Terminal strips in the control box numbered burner cable Fan motor Supply line During the thermostat connection Remove bridge Burner plug ...

Page 21: ...l We reserve the right to make modifications in dimensions and construction in the interests of technical progress F1 Control fuse F2 Fuse block fan motor F3 Thermal overcurrent relay fan motor F4 Fuse block burner motor optional H2 Malfunction lamp burner H3 Operating lamp burner H4 Malfunction lamp overheating H5 Operating lamp fan H6 Malfunction lamp fan KB REMKO triple combination control K1M ...

Page 22: ...22 Exploded View VRS 20 INOX We reserve the right to make modifications in dimensions and construction in the interests of technical progress ...

Page 23: ...r malfunction 1105513 13 Control lamp GREEN operation display 1105514 14 Operating switch 1101188 15 Unit frame cpl 1103148 16 Base plate 1103149 17 Air supply fan cpl 1108606 18 Air intake grille back 1103150 19 Intermediate plate 1130151 20 Fan regulator TR 1101683 21 Insulation back 1103152 22 Lining plate back 1103153 23 Rosette for exhaust gas connection 1103285 24 Blow out grille side 109534...

Page 24: ...Replacement for No 6 for design size 130 and higher Fig Fan with belt operation Exploded View VRS INOX We reserve the right to make modifications in dimensions and construction in the interests of technical progress ...

Page 25: ... 1103255 1103255 1103255 1103255 15 Flue gas brake 1102953 1102954 1102955 1102956 1102967 1102957 1102957 16 Fan cpl 230 V 1 1108423 1108602 17 Slotted plate suction 1103260 1103261 1103261 1103262 1103268 1103269 1103269 18 Seal for inspection cover 1103273 1103273 1103274 1103274 1103275 1103275 1103275 19 Inspection cover side 1103278 1103278 1103279 1103279 1103280 1103280 1103280 20 Seal for...

Page 26: ...5 a b 20 26 13 27 30 31 32 33 34 28 18 19 24 23 21 22 17 16 2 3 4 1 29 35 Exploded View VRS B Fig VRS 80 upright model We reserve the right to make modifications in dimensions and construction in the interests of technical progress ...

Page 27: ...90 1104291 1104291 16 Seal 1104292 1104292 1104292 1104292 1104292 1104293 1104293 1103234 1103234 1103234 17 Burner plate 1104294 1104294 1104294 1104294 1104294 1104295 1104295 1103237 1103237 1103237 18 Lining plate front middle 1104297 1104298 1104298 1104299 1104299 1104300 1104300 1104301 1104302 1104302 19 Insulation front middle 1104304 1104305 1104305 1104306 1104306 1104307 1104307 20 Bl...

Page 28: ...C 1285 1500 1700 1700 1800 2095 2260 2260 C1 1470 1570 1870 2070 2270 D 580 955 1052 1052 1100 1230 1330 1330 E 890 815 900 900 907 1075 1160 1160 F 35 35 35 35 35 35 35 35 G 262 335 435 435 485 540 635 635 R 150 150 150 180 180 200 200 200 Standing Unit Unit on its side C D B A E ø R C1 B G F A We reserve the right to make modifications in dimensions and construction in the interests of technical...

Page 29: ...E 545 775 775 928 928 1234 1234 1377 1530 1530 F 1073 1210 1210 1325 1583 1092 1092 1123 1257 1257 G 515 515 515 515 622 622 622 605 765 765 ø P 120 130 130 145 142 190 190 215 240 240 R ø 150 150 180 180 180 200 250 250 300 300 S 982 976 976 1078 1308 1392 1392 1520 1736 1736 Weight kg 190 260 305 365 450 680 735 930 1055 1240 dependent on the respective oil or gas forced air burner Standing Unit...

Page 30: ... damage Maintenance burner Test run Model Model No Burner Burner No Maintenance work may only be performed by authorised personnel settings must comply with legal specifications A corresponding test log must be kept Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature Signature Signature 6 Date 7 Date 8 Date 9 Date 10 Date Signature Signature Signature Signature Signature 11 Da...

Page 31: ......

Page 32: ...REMKO GmbH Co KG Klima und Wärmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 ...

Reviews: