Page 1: ...Edition GB T03 REMKO SLE 20 Swimming pool dehumidifier Operation Technology Spare parts...

Page 2: ......

Page 3: ...pted Dehumidification 4 6 Safety notices 6 Description of the unit 7 Installation 8 Commissioning 9 Decommissioning 10 Care and maintenance 10 Troubleshooting 11 Electrical wiring diagram 12 Refrigera...

Page 4: ...r escaping from buildings or materials is absorbed by the ambient air This increases their moisture content and ultimately results in corrosion mould rot peeling of paint coatings and other unwanted m...

Page 5: ...uilding materials or structures can absorb substantial amounts of water e g bricks 90 190 l m heavy concrete 140 190 l m lime sand bricks 180 270 l m The drying out of moist materials e g masonry take...

Page 6: ...ise of temperature The time necessary for drying normally does not depend only on the unit capacity but is rather determined by the rate at which the material or parts of the build ing release their m...

Page 7: ...tion openes integrated at the bottom of the front panel This is transported via a filter evaporator and condenser Heat is extracted from the room air on the cold evaporator and cooled to below the dew...

Page 8: ...at the bottom of the unit The condensate drain must be connected to the supplied drain connection not fitted A solid or flexible drain connection can be connected The drain hose must always be instal...

Page 9: ...screws on the sides of the housing Route the cable of the electromagnetic switch through the diaphragm sleeve at the bottom of the unit and connection to terminal 13 and 14 on the control board Refit...

Page 10: ...should be heavily fouled these can be cleaned carefully with soapy water Do not use a direct jet of water e g high pressure cleaner etc Do not use caustic cleaning agents or those containing solvents...

Page 11: ...ee The unit operates but no condensate forms Check room temperature The operating range of the unit is between 3 C and 30 C Check the air humidity min 40 relative humidity is necessary Check the sucti...

Page 12: ...2 Electronic control board Legend M1 Compressor M2 Fan TS1 Condenser sensor TS2 Evaporator sensor Y1 Solenoid valve Legend 1 Compressor 2 Evaporator 3 Condenser 4 Capillary tube 5 Dry filter 6 Solenoi...

Page 13: ...0 9 Front panel 1109142 2 1 3 4 5 6 8 9 7 Additional condensate container Where it is not possible or difficult to provide a natural condensate drain the unit can be provided with an additional conden...

Page 14: ...reserve the right to make changes to dimensions and the design in the interest of technical advances Diagram of unit SLE 20 21 10 12 13 15 2 1 23 19 24 25 26 3 9 28 6 8 4 14 27 22 16 17 14 REMKO SLE...

Page 15: ...Electronics cover 1109109 15 Solenoid valve complete 1109110 16 Condenser NTC sensor 1109111 17 Evaporator NTC thermistor metal 1109112 19 Mains cable with plug 1109124 21 Condenser 1109114 22 Evapor...

Page 16: ...is not liable for any damage attributed to failure to observe the manufacturer s instructions or applicable statutory requirements or unauthorised changes to the unit ATTENTION Copyright Reproduction...

Page 17: ...de to the supplied unit without our prior permission Name of manufacturer REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 D 32791 Lage Unit machine type Permanently installed dehumidifier Ser...

Page 18: ...nature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Unit type Serial number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Unit cleaned outside Unit cleaned insi...

Page 19: ...ntity g 190 Power supply V Hz 230 1 50 Max nominal current consumption A 2 1 Max power input kW 0 39 Sound pressure level LpA 1m 1 dB A 46 Depth mm 240 Width mm 535 Height mm 600 Weight kg 28 EDP No 6...