Technical data
1) Air intake temp. TK 27°C / FK 19°C, outdoor temp. TK 35°C / FK 24°C, max. air volume, 5m pipe length in combination with MVT 900 / 950 DC
2) Air intake temperature TK 20°C outdoor temperature TK 7°C, FK 6°C, max. air volume, 5m pipe length in combination with MVT 900 / 950 DC
3) Gap 1 m free space 4) Contains greenhouse gas according to Kyoto protocol
Range
RVD 351DC
RVD 521DC
RVD 681DC
RVD 1051DC
Operational mode
Cooling / heating
Nominal cooling output
1)
kW
3,52 (1,41 to 4,11) 5,27 (1,59 to 5,65)
7,03 (1,63 to 7,92) 10,55 (3,01 to 13,22)
Nominal heating output
2)
kW
4,29 (1,43 to 4,83) 5,86 (1,45 to 6,15)
7,76 (1,75 to 8,61) 11,72 (3,75 to 14,02)
Energy efficiency class, cooling
1)
A
A
A
A
Energy efficiency ratio EER
1)
3,32
3,25
3,22
3,25
Energy efficiency class, heating
2)
A
A
B
A
Coefficient of performance COP
2)
3,61
3,80
3,42
3,64
Power consumption, annual, (500h) C/H
530 / 595
1090 / 1060
1190 / 1060
1625 / 1600
Operating range (room volume), approx.
m³
110
160
230
320
Coolant
410A
4)
Power supply
V/Hz
230/1~/50 Hz
400 / 3~ / 50
Nom. elect. power consumption,cooling
1)
kW
1,06 (0,41-1,45)
1,62(0,56-2,63)
2,18 (0,84-2,35)
3,25 (2,31-5,50)
Nom. elect. power consumption,heating
2)
kW
1,19 (0,38-1,88)
1,54 (0,72-2,65)
2,12 (0,72-2,72)
3,20 (2,00-5,22)
Electr. rated power consumption
kW
1,90
2,60
3,25
5,50
Electr. nominal power consumpt. cooling
1)
A
4,34 (2,02-12,24)
7,08 (2,43-12,35)
10,30 (3,65-11,52) 14,62 (10,09-25,01)
Electr. nominal power consumpt. heating
2)
A
6,64(2,06-12,03)
6,82 (3,13-12,32)
10,05 (3,22-12,81)
14,35 (8,69-23,64)
Electr. starting current, max.
A
12,0
12,0
15,5
25,0
Coolant connection - injection line
Inches
(mm)
1/4 (6,35)
1/4 (6,35)
3/8 (9,52)
3/8 (9,52)
Coolant connection - suction line
Inches
(mm)
1/2 (12,70)
1/2 (12,70)
5/8 (15,90)
5/8 (15,90)
Max. operating pressure
kPa
4200 / 2500
Corresponding
indoor unit
RVD 351DC IT RVD 521DC IT RVD 681DC IT RVD 1051DC IT
Adjustment range, room temperature
°C
+17-+30
Operating range
°C
+17-+31
Air flow volume per speed setting
m³/h
510/530/680
560/710/800
820/1010/1220 1100/1300/1530
Sound pressure level per speed setting
3)
dB(A)
33/37/40
37/40/42
39/41/43
41/42/44
Protection degree
IP
X0
Condensate drain
mm
25
32
Condensate pump, flow rate, max.
mmWS
500
750
Dimensions - Height
mm
255
250
300
Width
mm
580
840
Depth
mm
580
840
Dimensions Cover length / width
mm
650 / 650
950 / 950
Weight
kg
18,0
21,0
29,0
30,0
Corresponding
outdoor unit
RVD 351DC AT RVD 521DC AT RVD 681DC AT RVD 1051DC AT
Operating range - cooling
°C
+5 - +43
Operating range - heating
°C
-5 - +24
Air flow rate, max.
m³/h
1600/2500
2300/2570
3000 /3250
5800 /6000
Protection degree
IP
24
Noise output max.
3)
dB(A)
48
52
53
55
Refrigerant, basic quantity
kg
1,40
1,70
2,30
4,10
Refrigerant, additional quantity > 5 m
g/m
30
30
30
30
Refrigerant pipe, max. length
m
15
25
25
30
Refrigerant pipe, height indoor unit and
outdoor unit max.
m
10
10
10
20
Dimensions - Height
mm
590
700
860
990
Width
mm
760
845
895
940
Depth
mm
280
310
335
360
Weight
kg
39,0
59,0
73,0
87,0
Serial number
548...
549...
713...
714...
EDP no.
1623160
1623170
1623180
1623190
REMKO RVD...DC
48