Description of Device 

 
The room air-conditioners in the REMKO RKV 10 W,  
13 W, 18 W and RKV 24 W series are split-design, wall-
mounted, direct-condensing units. 
The way the air conditioning system works is quite sim-
ple; warm air is removed from the room to be cooled. 
The environmentally-friendly refrigerant R 407C trans-
ports this warmth just as it does for all other REMKO 
air-conditioning products. 
The units primary function is to air-condition rooms. 
They also filter and dehumidify the air, thus creating a 
comfortable climate in the room. The units also have a 
pure ventilation and dehumidification mode. 
All units operate fully-automatically and offer a range of 
other options thanks to their microprocessor control. 
They are operated using the supplied infrared remote 
control.

 

Safety Hints 

 
Extensive tests have been conducted on the material, 
functionality and quality of these units before they were 
shipped. These units may only be used in accordance 
with their intended purpose. Hazards may arise if the 
units are used improperly. 

Please make sure to follow these safety instructions. 

à

Never operate the indoor unit outside or without the 
air filter. 

à

Make sure that personnel trained in the operation of 
the air conditioner check the unit for visible defects 
on the operating and safety mechanisms each time 
before putting it into operation. 

à

Before performing any work on the unit, the power 
cord must be unplugged and the unit secured 
against being switched on by unauthorised persons. 

à

Operate the units only when assembled and for their 
intended purpose. 

à

Keep in mind that it is dangerous to remove covers 
protective grilles, etc., during operation; this can lead 
to uncontrolled operating situations. 

à

The indoor unit and the outdoor part of the REMKO 
air-conditioners have been technically adjusted to 
one another.

       

If third-party components are used, the guarantee 
becomes null and void.

 

à

Operate the units exclusively within the permissible 
operating ranges.         

Pay attention to surrounding temperatures. 

à

Make sure that the unit is kept at a safe distance 
from flammable materials. 

à

Do not install the inside unit close to heaters or be-
hind curtains and drapes.        

Maintain the minimum safety distances indicated!

 

à

Ensure that the air intake and outlet openings are al-
ways clear of foreign objects. 

à

Do not insert any objects into the air intake and out-
let openings. 

à

Do not place any objects on top of the units. 

à

Never operate the units in rooms susceptible to ex-
plosions. 

à

The units are also not suitable for operation in rooms 
containing large amounts of dust or aggressive air. 

à

Do not use flammable sprays such as hair spray or 
spray paint in the direct vicinity of the units. 

à

Do not operate the units if the atmosphere is con-
taminated by oil, sulfur or salt. 

à

Do not expose the unit to direct streams of water. 

High-pressure cleaners, etc.

 

à

Protect the indoor unit and the remote control from 
moisture and direct sunlight. 

à

Never open the units’ housing!         

This may cause an electric shock.

 

à

Regularly check that condensation is not blocked 
from flowing out of the unit. 

à

Make sure that the outdoor part is equipped with a 
safety mechanism which prevents the condenser 
from being damaged caused by the unit switching 
back on right away after it has been switched off.

 

The unit may only be switched back on after 3 min-
utes.

 

à

Cleaning and minor maintenance work made only be 
performed by the operator or an authorised person 
designated by him in accordance with the instruc-
tions contained in the section "Maintenance and 
Service". 

à

All REMKO air conditioners are supplied with the en-
vironmentally-friendly refrigerant R 407C. 

à

Installation and repair work may only be performed 
by authorised personnel. 

Transport and Packaging 

 
The unit is shipped in a stable transport box made of 
cardboard. Please examine the unit when it is delivered.  
Make note of any damage or missing parts on the ship-
ping bill and notify the shipping company and your con-
tract partner. 
We do not assume any liability for subsequent com-
plaints. 

Summary of Contents for RKW 10 W

Page 1: ...REMKO powerful like a bear REMKO RKV 10 W 13 W 18 W 24 W Multi purpose room air conditioners Edition GB P05 Operation Technology Spare Parts...

Page 2: ......

Page 3: ...n 14 Condensation Connection 15 External Condensation Pump 15 Prior to Initial Operation 17 Initial Operation 17 Environment and Recycling 18 Customer Service and Guarantee 18 Internal Wiring Diagram...

Page 4: ...the units exclusively within the permissible operating ranges Pay attention to surrounding temperatures Make sure that the unit is kept at a safe distance from flammable materials Do not install the i...

Page 5: ...e The difference between the point at which it switches on and off hysterisis is higher than in cooling mode 7 Temp button The temperature button can be used to set the de sired temperature in 0 5 C i...

Page 6: ...unit to switch on or off at a later time If the room air conditioner is to be switched on at a later time press the or button for approximately 2 seconds when the unit is off In both operating modes...

Page 7: ...ou hear a beep the COMP display begins to blink for approximately 3 minutes This waiting period is a forced pause to increase the service life of the compressor and the outdoor part Once the display s...

Page 8: ...the filters and close the grille Maintenance and Service Shutting Down the Unit Temporary shutdown 1 Switch the indoor unit off using the remote control 2 Disconnect the system with the main switch o...

Page 9: ...nsmission signal at a dis tance of approx 3 m when the but ton is pressed Reduce distance to under 6 m and change location Remote control defective Does the unit work in manual mode Replace remote con...

Page 10: ...40 65 Power consumption cooling A 0 2 0 2 0 2 0 4 Current consumption max A 0 2 0 2 0 2 0 4 Supply diffuse protection recommended A See corresponding outdoor part Operating range cooling C 15 C bis 30...

Page 11: ...oid if third party components are used Remember that when installing and maintaining air conditioners high pressure refrigerant lines and electrical current can pose hazards During unit operation some...

Page 12: ...n and con trol lines see figure below 4 3 2 1 5 Units RKV 10 W RKV 13 W and RKV 18 W can be connected using all five options while the RKV 24 W units can only be connected using options 1 to 3 1 Outfl...

Page 13: ...5 If you have selected Option 2 or 4 drainage through the wall guide the condensation water and control line through the wall lead through to the indoor unit If you also need a condensation pump it mu...

Page 14: ...terminal strip of the connection towards you out of the unit Please observe the following We recommend that the customer install a main or repair switch close to the outdoor part Power is supplied to...

Page 15: ...n If the unit is being operated at outside temperatures below 0 C the lines must be placed in such a way that they are protected from frost External Condensation Pump The condensation pump which can b...

Page 16: ...ly The end of the ventilation hose must at least be at the same height as the con densation tray to prevent water from overflowing The supplied metal wire clips are used to secure the hose in a vertic...

Page 17: ...values in the initial operation log Cooling operation test run Perform a test run for cooling operation as follows 1 Switch the customer installed main switch or fuse on 2 Adjust the target temperatur...

Page 18: ...horised personnel may come into contact with the cold cycle This ensures that refrigerant does not es cape into the environment when the unit is being re paired Both the refrigerant and the system par...

Page 19: ...tup location Name Street Postal code city Telephone Fax Testing of cycles A B C D Result Visible check Setup of outdoor part and indoor unit R good Q poor Heat exchanger insulation lines R good Q poor...

Page 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 E Mail info remko de Internet www remko de...

Reviews: