Safety Hints 

 
Extensive tests have been conducted on the material, 
functionality and quality of these units before they were 
shipped. These units may only be used in accordance 
with their intended purpose. Hazards may arise if the 
units are used improperly. 

à

The indoor unit is not suitable for outside operation! 

à

Make sure that personnel trained in the operation of 
the air conditioner check the unit for visible defects 
on the operating and safety mechanisms each time 
before putting it into operation! 

à

Before performing any work on the unit, the power 
cord must be unplugged and the unit secured 
against being switched on by unauthorised persons! 

à

Operate the units only when assembled and for their 
intended purpose. 

à

Keep in mind that it is dangerous to remove covers 
protective grilles, etc., during operation; this can lead 
to uncontrolled operating situations!  

à

Operate the units exclusively within the permissible 
operating ranges.         

Surrounding temperatures.

 

à

Make sure that the unit is kept at a safe distance 
from flammable objects! 

à

Do not install the inside unit close to heaters or be-
hind curtains and drapes!  

à

Ensure that the air intake and outlet openings are not 
blocked and always clear of foreign objects! 

à

Do not place any objects on top of the units! 

à

The unit part may only be connected to a correctly 
installed and grounded power supply. 

à

Do not operate the units if the atmosphere is con-
taminated by oil, sulfur or salt. 

à

Never operate or use the units in rooms susceptible 
to explosions. 

à

The units are also not suitable for operation in rooms 
containing large amounts of dust or aggressive air. 

à

Do not use flammable sprays such as hair spray or 
spray paint in the direct vicinity of the units. 

à

Do not expose the unit to direct streams of water. 

à

Protect the indoor unit and the remote control from 
moisture and direct sunlight. 

à

Protect all electric cables and connection lines from 
being damaged, for example, by animals. 

à

Protect the indoor unit and the remote control from 
direct and indirect sunlight. 

à

Do not expose the remote control to strong vibra-
tions. 

à

Regularly check that condensation is not blocked 
from flowing out of the unit. 

à

Never operate the units without the air filters.

 

Description of Device 

 
The room air-conditioners in the REMKO RKV 13 T /  
24 T series are split-design, direct-condensing units that 
can be mounted on the wall or ceiling. 
The way the air conditioning system works is quite sim-
ple: 
Warmth is removed from the room to be cooled. The 
environmentally-friendly refrigerant R 407C transports 
this warmth just as it does for all other REMKO air-
conditioning products. 
The units’ primary function is to air-condition rooms. 
They also filter and dehumidify the air, thus creating a 
comfortable climate in the room. The units also have a 
pure ventilation and dehumidification mode. 
All units operate fully-automatically and offer a range of 
other options thanks to their microprocessor control. 
They are operated using the supplied infrared remote 
control. 
If the infrared remote control is defective or the batteries 
are dead, the units can be started via an emergency 
switch on the indoor unit (also in manual operation). 

à

The unit is equipped with a safety mechanism which 
prevents the condenser from being damaged caused 
by the unit switching back on right away after it has 
been switched off. It is only possible to restart after 3 
minutes. 

à

Cleaning and minor maintenance work may only be 
performed by the operator or an authorised person 
designated by him in accordance with the instruc-
tions contained in the section "Maintenance". 

à

Installation and repair work may only be performed 
by authorised personnel 

à

All REMKO air conditioners are supplied with the en-
vironmentally-friendly refrigerant R 407C. 

Transport and Packaging 

 
The unit is shipped in a stable transport box made of 
cardboard. Please examine the unit when it is delivered. 
Make note of any damage or missing parts on the ship-
ping bill and notify the shipping company and your con-
tract partner.  
We do not assume any liability for subsequent com-
plaints. 

Summary of Contents for RKV 13 T

Page 1: ...REMKO powerful like a bear REMKO RKV 13 T 24 T Wall Ceiling Chests Edition GB P05 Operation Technology Spare Parts...

Page 2: ......

Page 3: ...ctrical Connection 13 Condensation Connection 14 External Condensation Pump 15 Prior to Initial Operation 16 Initial Operation 17 Environment and Recycling 17 Customer Service and Guarantee 17 Certifi...

Page 4: ...als Protect the indoor unit and the remote control from direct and indirect sunlight Do not expose the remote control to strong vibra tions Regularly check that condensation is not blocked from flowin...

Page 5: ...oom 4 Timer button You can program the unit to automatically switch on or off within the next 24 hour period with the timer 5 Sleep button If the Sleep function is activated the set room tem perature...

Page 6: ...e the COOL mode when you want to cool the room to the desired temperature Reduce the desired temperature by pressing the Temperature button in 0 5 C in crements After you hear a beep the COMP display...

Page 7: ...room air conditioner is to be switched off at a later time press when of these buttons when the remote control is on In both operating modes 12 0H appears in the lower right hand corner of the displa...

Page 8: ...ce left right 6 Closed the front of the unit Shutting Down the Unit Temporary shutdown 1 Switch all indoor units off using the remote control 2 Disconnect the system with the main switch or fuse prote...

Page 9: ...batteries with the correct polarity Transmission distance too great reception blocked Is the transmission signal at a dis tance of approx 3 m when the but ton is pressed Reduce distance to under 6 m...

Page 10: ...e line RKM Inch mm 1 4 6 35 Connection intake line RKM Inch mm 1 2 12 7 Additional amount to add 2 g m 18 15 Dehumidification capacity l h 1 0 2 0 Power supply V Hz 230 1 50 Hz supplied via outdoor pa...

Page 11: ...blocked by furniture curtains etc Make sure that the electrical terminals have been properly attached The refrigerant lines may not be bent or pressed Protect open refrigerant lines from moisture with...

Page 12: ...mm screws bolts as well as washers to the ceiling An incline of approx 8 mm to the connection adaptor must be maintained to ensure that the condensation can flow freely Wall mount Ceiling mount Insta...

Page 13: ...lled The electrical installations may only be performed by author ised personnel in line with the relevant regulations Local guidelines for operation as well as the requirements es tablished by local...

Page 14: ...information The condensation drainage line is generally placed in the same guideway as the refrigerant lines If as a result of structural design conditions it is necessary to have a different guidewa...

Page 15: ...ed on Kondensatab laufschlauch Entl ftungsschlauch kurz Pumpe Reservoir Ansaugschlauch lang Tropfwanne Condensation drainage hose Ventilation house short Pump Collection tray Reservoir Suction hose lo...

Page 16: ...he condensation pump Before putting the pump into operation the lines that have been laid must be checked to ensure that they are functioning properly and leakproof 1 Switch the power supply of the pu...

Page 17: ...n mode and dehu midifying mode 6 Adjust the plate fins correctly to prevent air from be ing distributed unfavourably 7 Familiarise the operator with the system and give him the certificate for initial...

Page 18: ...permeability check of the connections on the outdoor part and indoor unit s OK problem Shut off valves on the outdoor unit open if applicable OK problem Test run of unit operation Compressor fan outdo...

Page 19: ......

Page 20: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 E Mail info remko de Internet www remko de...

Reviews: