background image

18

REMKO PGM (E) series

Exploded view of PGM 60 (E)

We reserve the right to modify the dimensions and design as part of the ongoing technical development process.

8

7

9

10

12

18

15

14

13

16

17

19

8

20

21

16

22

23

28

11

24

22

26

27

29

30

32

31

35

36

37

38

39

33

41

34

24

1

2

3

4

40

5

6

12

11

Summary of Contents for PGM 30

Page 1: ...g and installation instruction This product is not suitable as a main heater Edition GB Q04 Read the instructions prior to performing any task PGM 30 E PGM 60 E REMKO PGM E series Propane gas heating...

Page 2: ......

Page 3: ...modifications no liability accepted for errors or misprints Safety notes 4 Unit description 5 Installation instructions 6 Gas connection 7 9 Commissioning 9 10 Shutdown 11 Care and maintenance 11 12 T...

Page 4: ...prior to delivery However dangers can arise from the units if they are used improperly or not as intended by untrained personnel Please observe the following information The units may only be operate...

Page 5: ...ust gas burners with thermal monitoring electric solenoid valve piezo ignition and mains cable with earthed safety plug The units are intended exclusively for manual operation and cannot be thermostat...

Page 6: ...n well ventilated spaces and not in living areas or similar recreational areas Installation instructions The safety regulations of the accident prevention and insurance associations the respective reg...

Page 7: ...nit connection pressure of 1 5 bar It is prohibited to exceed or undershoot the connection pressure When using longer hose lines consider the respective pressure loss Only use components that have bee...

Page 8: ...supply tank 1 6 2 4 5 4 3 6 5 6 Attachment multi cylinder set accessory In order to ensure a regular gas take off insofar as possible all cylinder valves must be open The cylinder battery can be expa...

Page 9: ...switch to the 0 off position 2 Connect the unit s power plug to a properly installed and fused mains socket Connect 230 V 50 Hz The units should be checked for visible defects on the operating and saf...

Page 10: ...es 4 After a flame appears depress the pressure pin 2 for a further approx 10 15 sec until the thermal flame monitoring is activated 5 If the flame goes out when the pressure pin 2 is released repeat...

Page 11: ...ve or solvent based cleaners Use only suitable cleaners even for heavy contamination Check the inlet and outlet grille for contamination on a regular basis Check hoses and seals for damage on a regula...

Page 12: ...extremely sensitive capillary tube here 8 Carefully remove any adhered deposits from the ignition electrode and thermocouple 9 Detach the fastening screws of the gas burner and remove the complete gas...

Page 13: ...niter Check the thermocouple or temperature limiter and replace if necessary Check the connection and clean if necessary Fit an original pressure controller Disengage or replace the hose breakage prot...

Page 14: ...not intended for domestic use without heat exchangers with forced convection The units must only be operated by appropriately instructed personnel With non observance of the manufacturer s specificati...

Page 15: ...15...

Page 16: ...PGM 30 E 1 2 3 4 5 6 7 8 9 11 14 12 15 14 18 13 19 17 16 12 21 19 15 23 24 25 26 27 32 33 34 35 36 10 28 10 37 6 20 9 31 30 29 We reserve the right to modify the dimensions and design as part of the...

Page 17: ...101396 24 Solenoid valve 1101376 25 Gas connection nipple 1101134 26 Adjusting knob cpl 1101192 27 Operating switch 1101188 28 Strain relief 1101267 29 Mains cable with plug 1101320 30 Completion pane...

Page 18: ...60 E We reserve the right to modify the dimensions and design as part of the ongoing technical development process 8 7 9 10 12 18 15 14 13 16 17 19 8 20 21 16 22 23 28 11 24 22 26 27 29 30 32 31 35 36...

Page 19: ...1101134 30 Adjusting knob cpl 1101192 31 Strain relief 1101267 32 Operating switch 1101188 33 Terminal block 6x 1101366 34 Grommet 1101304 35 Mains cable with plug 1101320 36 Protective intake grille...

Page 20: ...9 Date Signature 20 Date Signature Comments Unit to be maintained only by authorised specialists in accordance with the statutory regulations Unit type Unit number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 21: ...umption at nominal heating capacity elmax kW 0 070 0 100 at minimum heating capacity elmin kW 0 070 0 100 in Standw By mode elSB kW 0 000 0 000 Pilot flame power requirement Ppilot kW N A N A Thermal...

Page 22: ...2 1 5 4 3 2 1 6 STB MV M 1 S C 1 A3 A2 A1 B4 B5 B6 PZ TMV TE Z Legend KL Terminal block M Fan motor MV Solenoid valve PZ Piezo igniter S Operating switch STB Safety temperature limiter TE Thermocoupl...

Page 23: ...23...

Page 24: ...5232 606 260 E mail info remko de URL www remko de REMKO GmbH Co KG Klima und W rmetechnik Im Seelenkamp 12 32791 Lage Hotline within Germany 49 0 5232 606 0 Hotline International 49 0 5232 606 130 W...

Reviews: