9.4 Terminal assignment / legend
Terminal assignment
Designat.
Input
Output
Signal
Description
PW
X
Power supply I/O 230V
PP1
X
Power supply primary pump, indoor unit
S01
X
Solar probe collector PT 1000
S02
X
Solar probe storage tank bottom PT 1000
S03
X
Solar probe inlet heat meter Solar PT 1000
S04
X
Solar probe return flow heat meter Solar PT 1000
S05
X
Circ. probe PT 1000 Return flow Temp./Pulse encoder
S06
X
Probe inlet 2nd mixed heating cycle inlet PT 1000
S07
X
Not connected
S08
X
Probe drinking water tank top PT 1000
S09
X
Probe buffer storage tank middle PT 1000
S10
X
External probe PT 1000
S11
X
Probe 1st mixed heating cycle return flow PT 1000
S12
X
Probe 1st mixed heating cycle inlet PT 1000
S13
X
Not connected
S14
X
Probe 2nd mixed heating cycle return flow
S15
X
Not connected
S16
X
Power utility contact (NC) / dewpoint monitoring external
(open = locked, closed = release)
S20
X
Not connected
S21
X
Not connected
S22
X
Not connected
S23
X
Ultrasonic flow rate meter Solar, pulse rate
S24
X
Not connected
S25
X
Heat pump electricity meter S0
S26
X
Household electricity S0
S27
X
Flow probe
S28
X
Photovoltaics yield electricity meter S0
S29
X
Photovoltaics in-feed electricity meter S0
A01
X
Solar pump unregulated (230 V)
A02
X
1st mixed heating cycle pump (230 V) switched
A03
X
Pump unmixed Heating cycle HK (230 V) switched
A04
X
Circulation pump (230V) switched
A10
X
Changeover valve, drinking water
REMKO LWM series