2.2 Product data
Average condition
1)
Series
LWM 80
LWM 110
LWM 150
Energy efficiency ratio, heating 35°C/55°C
A++/A++
Nominal heating power P rated
kW
5
7
10
Room heating energy efficiency
h
s 35°C/55°C
%
161/136
161/142
164/138
Contribution to the seasonal room heating
energy efficiency of the REMKO Smart-Control
%
4
Yearly energy consumption Q
HE
35°C/ 55°C
4)
2629/3173
3395/3797
4588/5780
Sound power level L
WA
dB(A)
56
58
60
Warmer condition
2)
Series
LWM 80
LWM 110
LWM 150
Energy efficiency ratio, heating 35°C/55°C
A++/A++
Nominal heating power P rated
kW
4
6
8
Room heating energy efficiency
h
s 35°C/55°C
%
182/160
187/167
169/164
Yearly energy consumption Q
HE
35°C/ 55°C
4)
1326/1379
1668/1638
2550/2537
Colder condition
3)
Series
LWM 80
LWM 110
LWM 150
Energy efficiency ratio, heating 35°C/55°C
A++/A++
Nominal heating power P rated
kW
7
9
13
Room heating energy efficiency
h
s 35°C/55°C
%
147/114
145/122
148/120
Yearly energy consumption Q
HE
35°C/ 55°C
4)
4158/6135
5485/7278
7319/10700
1)
Average condition = Moderate temperature periods
2)
Warmer condition = Warm temperature periods
3)
Colder condition = Cold temperature periods
4)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
11