background image

Spare parts list

No.

Designation 

KWL 

130

KWL 

160

KWL 180 KWL 220

KWL 

130 H

KWL 

160 H

KWL 180 

H

KWL 220 

H

1

Operating panel, compressor element RAL

1110001

1110001

1110002

1110002

1110001

1110001

1110002

1110002

1

Operating panel, compressor element INOX 1110760

1110760

1110761

1110761

1110760

1110760

1110761

1110761

2

Condenser protective grid RAL

1110003

1110003

1110004

1110004

1110003

1110003

1110004

1110004

2

Condenser protective grid INOX

1110762

1110762

1110763

1110763

1110762

1110762

1110763

1110763

3

Condenser protective grid RAL

1110005

1110005

1110006

1110006

1110005

1110005

1110006

1110006

3

Condenser protective grid INOX

1110764

1110764

1110765

1110765

1110764

1110764

1110765

1110765

4

Fan panel RAL

1110007

1110007

1110008

1110008

1110007

1110007

1110008

1110008

4

Fan panel INOX

1110766

1110766

1110767

1110767

1110766

1110766

1110767

1110767

5

Side panel RAL

1110009

1110009

1110010

1110010

1110009

1110009

1110010

1110010

5

Side panel INOX

1110768

1110768

1110769

1110769

1110768

1110768

1110769

1110769

6

Side panel RAL

1110011

1110011

1110012

1110012

1110011

1110011

1110012

1110012

6

Side panel INOX

1110770

1110770

1110771

1110771

1110770

1110770

1110771

1110771

7

Roof panel RAL

1110013

1110013

1110014

1110014

1110013

1110013

1110014

1110014

7

Roof panel INOX

1110772

1110772

1110773

1110773

1110772

1110772

1110773

1110773

8

Finned condenser 

1110017

1110018

1110019

1110019

1110540

1110541

1110542

1110543

9

Condenser fan

1110020

1110020

1110021

1110021

1110020

1110020

1110021

1110021

10

Evaporator

1110022

1110022

1110023

1110023

1110022

1110022

1110023

1110023

11

SANYO compressor

1110024

1110025

1110026

1110027

1110024

1110025

1110026

1110027

11

Danfoss-Maneurop compressor

-

-

-

1106715

-

-

-

1106715

12

Expansion valve, cpl.

1110028

1110029

1110029

1110030

1110028

1110029

1110029

1110030

13

Diaphragm expansion vessel

1110036

1110036

1110037

1110037

1110036

1110036

1110037

1110037

14

Circulation pump

1110033

1110033

1110033

1110033

1110033

1110033

1110033

1110033

15

Differential pressure switch

1110034

1110034

1110035

1110035

1110034

1110034

1110035

1110035

16

Controller covering

1110051

1110051

1110051

1110051

1110051

1110051

1110051

1110051

Spare parts (not illustrated)

Safety valve

1110038

1110038

1110038

1110038

1110038

1110038

1110038

1110038

Control system protection switch

1110039

1110040

1110040

1110040

1110039

1110040

1110040

1110040

Compressor protection switch

1110041

1110042

1110042

1110042

1110041

1110042

1110042

1110042

Circulation pump fuse

1110043

1110043

1110043

1110043

1110043

1110043

1110043

1110043

Phase sequence relay

1110044

1110044

1110045

1110045

1110044

1110044

1110045

1110045

IChill adaptive controller

1110046

1110046

1110046

1110046

1110046

1110046

1110046

1110046

IChill adaptive controller, programmed

1110047

1110048

1110049

1110050

1110544

1110545

1110546

1110547

Fan controller

1110052

1110052

1110054

1110054

1110052

1110052

1110054

1110054

Transformer

1110053

1110053

1110053

1110053

1110053

1110053

1110053

1110053

Sensor

1110055

1110055

1110055

1110055

1110055

1110055

1110055

1110055

Compressor protection

1110056

1110056

1110057

1110058

1110056

1110056

1110057

1110058

Circulation pump protection

1110059

1110059

1110059

1110059

1110059

1110059

1110059

1110059

Equipment cladding, set

1110015

1110015

1110016

1110016

1110015

1110015

1110016

1110016

High pressure monitor

1110031

1110031

1110031

1110031

1110031

1110031

1110031

1110031

Low pressure monitor

1110032

1110032

1110032

1110032

1110032

1110032

1110032

1110032

Condenser, condenser fan

1110061

1110061

1110062

1110062

1110061

1110061

1110062

1110062

Reversing valve, valve body

-

-

-

-

1110548

1110549

1110550

1110551

Reversing valve, coil

-

-

-

-

1110552

1110553

1110554

1110555

Pressure transducer winter pressure controller

1106361

1106361

1106361

1106361

1106361

1106361

1106361

1106361

When ordering spare parts, please state the computerised part no. and unit number (see identification plate) !

REMKO KWL (H)

40

Summary of Contents for KWL 130

Page 1: ...NOX KWL 220 INOX KWL 270 INOX KWL 320 INOX KWL 370 INOX KWL 130 H KWL 160 H KWL 180 H INOX KWL 220 H INOX KWL 270 H INOX KWL 320 H INOX KWL 370 H INOX Air cooled Chiller and Air cooled Chiller with He...

Page 2: ......

Page 3: ...nsport and packaging 5 System description 5 6 System configuration 7 Operation 7 13 Care and maintenance 14 Shut down 14 Trouble shooting and customer service 15 17 Installation instructions for quali...

Page 4: ...e malfunctions Equipment and components may not be operated in areas where there is an increased risk of damage Observe the minimum clearances The electrical supply is to be adapted to the requirement...

Page 5: ...nit an air to water chiller takes heat out of the operating medium to be cooled water or a mixture of water and glycol within a closed medium circuit in the evaporator plate heat exchanger and gives i...

Page 6: ...er dryer 13 Schrader valve 14 Thermal expansion valve cooling 15 Sensor medium intake 16 Sensor medium outlet 17 Fan control sensor Construction 1 1 3 3 4 4 5 5 6 6 7 7 17 17 8 8 9 9 14 14 11 11 11 10...

Page 7: ...output can be transmitted to the room to be cooled via the floor the building structure or by means of ceiling cooling For each of the different systems a minimum flow volume and a minimum medium vol...

Page 8: ...e is set The controller is divided into a left value display and a right function display M key With this key you reach the function menu or can adjust time and date SET With this key the selection of...

Page 9: ...on a different functional meaning of the display can be programmed Mode setting External contact Enable open Display of the current operating values The normal display shows the current medium intake...

Page 10: ...e is longer than 3 minutes the current target value is kept The medium temperature increases and the compressor is switched off when the shut off point is reached B Factory setting for target value St...

Page 11: ...ange the set value press the key for approx 5 seconds The display begins to blink With the or keys the value can be adjusted within the limits defined at the factory St 07 St 08 St 07 36 C Minimum tar...

Page 12: ...rd The menu program is automatically closed after 15 seconds if the controller is not actuated Querying the fault reports See chapter on troubleshooting and customer service open ALrM submenu short te...

Page 13: ...mp sensor target value C Sd 05 Outside temp sensor target value H Sd 06 Outside temp sensor hysteresis C Sd 07 Outside temp sensor Hysteresis H Pr2 Password ES 01 Switch on time ES 02 Shut off time ES...

Page 14: ...nsure trouble free operation and a long service life Prior to performing any work ensure the equipment is isolated from the voltage supply and secured to prevent accidental switch on CAUTION Care Ensu...

Page 15: ...not start the compressor icon in the display is flashing Delay time Wait out the delay time max 360 sec the compressor should then start The lower display flashes and alternately shows an alphanumeri...

Page 16: ...n the cooling circuit OK Have checked by a specialist A05 Excessive temperature condenser Are the fans turning Is the condenser s air intake free of obstacles Have checked by a specialist A06 Excess t...

Page 17: ...onfiguration error x x x x x x ACF3 Configuration error x x x x x x ACF4 Configuration error x CF28 x x x x AFr Power supply x x x x x x Reset 1 Faults with automatic reset The resetting of the alarm...

Page 18: ...on lines valves and connections must be insulated against vapour diffusion If necessary also insulate the condensate line only units with HP function In dual systems with cooling and heating modes the...

Page 19: ...the fins and reduces the heat released by the finned heat exchanger The unit should whenever possible be installed on the north side of the building If necessary take measures to provide sufficient sh...

Page 20: ...KWL 270 H 320 H KWL 370 H Minimum clearances The following illustration indicates the minimum clearances for trou ble free operation of the system These protection zones serve to ensure unrestricted...

Page 21: ...Load point F 55 59 72 58 60 75 6 Weight loads All values in kg KWL 130 H 160 H KWL 180 H 220 H KWL 270 H 320 H KWL 370 H KWL H with medium storage tank A C B D A C E F B D A C E F B D A C B D Installa...

Page 22: ...ompo nents is to be simulated using a pipe leg regulating valve The pipe sizing is to be de signed so that the required minimum flow volume is not under cut A permanent large flow volume must be ensur...

Page 23: ...and safety data sheets of the glycol type which is used must be ob served CAUTION Propor tion glycol Frost protection 2 C Correction factors when using a mixture of glycol and water Cooling capacity...

Page 24: ...ent of the realisation of a cooling heating system the installation of another diaphragm expansion vessel may be necessary Safety valve Safety valves limit excess operat ing pressure due to excess war...

Page 25: ...e condensate If necessary fit supplementary pipe heating After completed installation check that the condensate run off is unobstructed and ensure that the line is durably leak tight Condensate drain...

Page 26: ...n accordance with the applica ble regulations Check all terminal points for stability The supply line must be ad equately insulated on site and the voltage drop may not exceed permissible values Make...

Page 27: ...the programming the cooling mode is activated with a closed contact between terminals 2 and 3 Display temperatures 5 sec short short short short short change value short 8 External potential free cont...

Page 28: ...rd With a modulating output voltage the condenser fan s speed can be adjusted to the condenser tem perature and in this way hold the noise level to a minimum The iCHiLL controller determines the curre...

Page 29: ...signal 2 6 Cooling heating switching 7 12V 8 0V 9 10 Cable remote control Compressor Probe Intake High pressure switch Probe Outlet Low pres sure switch Probe LN contr Diff press switch Pressure tran...

Page 30: ...320 H KWL 130 H 160 H Compressor Circulation pump Fan controller Condenser fan 1 Condenser fan 2 Anti freeze heating cooling medium Accessories Reversing valve only KWL H CW heater Accessories REMKO...

Page 31: ...ing switching 7 12V 8 0V 9 10 Cable remote control Probe Intake High pressure switch Probe Outlet Low pres sure switch Probe LN contr Diff press switch Pressure transducer pressure reg Accessories Ant...

Page 32: ...V 8 0V 9 10 Cable remote control Compressor Probe Intake High pressure switch Probe Outlet Low pres sure switch Probe LN contr Diff press switch Pressure transducer pressure reg Accessories Circulatio...

Page 33: ...M11 Condenser fan 2 RC1 Compressor crank case heating TA Transformer 230 12V TR 3 not used accessory pressure transducer TX1 Thermal contact fan 1 TX2 Thermal contact fan 2 KWL 370 H Component equipm...

Page 34: ...AG The preliminary pressure for the diaphragm expansion vessel must be adjusted individually to the system layout the volume of the medium and the installation site If the unit is positioned at the lo...

Page 35: ...k the cooling cycle for leaks Observe the manuals for the unit and all other components when commissioning the entire system Commissioning The systems are equipped with a phase sequence relay which pr...

Page 36: ...d to the dimensions listed above to work after approx 3 min utes 5 Please note that the supply temperature at the nominal medium flow lies approx 5 K above the intake temperature The circulation pump...

Page 37: ...ic curves KWL 130 H KWL 160 H KWL 180 H KWL 220 H KWL 320 H KWL 270 H KWL 370 H l sec l sec l sec l sec l sec l sec l sec Circulation pump U P I KWL 130 H 320 H 230 400V 0 37 0 5kW 2 5 1 4A KWL 370 H...

Page 38: ...KWL 130 H kPa kPa l sec l sec kPa kPa l sec l sec kPa l sec kPa kPa l sec l sec KWL 160 H KWL 180 H KWL 220 H KWL 320 H KWL 270 H KWL 370 H Equipment pressure available REMKO KWL H 38...

Page 39: ...We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process Exploded view KWL 130 H 220 H 4 5 6 9 10 11 12 2 1 14 15 16 7 13 3 9 39...

Page 40: ...37 1110037 1110036 1110036 1110037 1110037 14 Circulation pump 1110033 1110033 1110033 1110033 1110033 1110033 1110033 1110033 15 Differential pressure switch 1110034 1110034 1110035 1110035 1110034 1...

Page 41: ...loded view KWL 270 H 370 H We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process 7 16 18 17 3 4 9 10 5 6 11 14 1 15 19 2 12 13 4...

Page 42: ...mpressor 1110088 1110089 1110090 1110088 1110089 1110090 14 Expansion valve cpl 1110030 1110091 1110092 1110030 1110091 1110092 15 Circulation pump 1110033 1110033 1110093 1110033 1110033 1110093 16 D...

Page 43: ...0 5 5 12 2 5 9 14 4 5 9 16 5 6 0 17 6 6 0 18 8 6 1 21 8 6 1 45 10 4 5 6 12 3 5 8 14 0 5 8 14 9 5 9 16 0 5 9 18 5 6 0 12 1 6 5 14 2 6 6 16 2 6 6 17 5 6 7 18 4 6 7 21 3 6 7 KWL 180 H KWL 220 H Air intak...

Page 44: ...4 43 7 1000 39 3 39 4 44 0 43 6 43 6 43 7 45 6 43 5 43 5 44 0 43 6 43 7 43 8 45 6 2000 41 1 41 1 43 4 42 9 43 0 43 0 47 1 42 7 42 7 43 4 42 9 43 1 43 3 47 1 4000 35 4 35 5 39 7 39 4 39 4 39 4 42 7 39...

Page 45: ...4 4 64 5 44 6 41 Minimum flow volume medium m h 1 40 1 80 2 00 2 40 3 00 3 50 4 1 Maximum flow volume medium m h 3 40 4 50 5 20 6 20 7 80 9 00 10 70 Nominal pump pressure max kPa 207 0 195 0 188 0 177...

Page 46: ...ing medium max 35 ethylene glycol max 35 propylene glycol Operating limits medium C 4 to 50 Max operating pressure medium kPa 300 Nominal flow volume medium C H m h 2 23 2 74 3 10 3 74 4 64 5 44 6 41...

Page 47: ...12 D 32791 Lage Equipment machinery Implementation Air cooled water chiller and Air cooled water chiller with heat pump function Series Model REMKO KWL 130 KWL 160 KWL 180 INOX KWL 220 INOX KWL 270 IN...

Page 48: ...ialists REMKO field staff are more than just sales representatives above all they must act as advisers to our customers in air conditioning and heating technology Customer Service Our equipment operat...

Reviews: