NOTE

After all adjustment tasks the 
doors must be closed. 
In order to prevent  
unauthorized operation, the 
doors should also be locked.

The inlet fan continues to run 
to cool the combustion  
chamber and the heat ex-
changer and does not switch 
off until later. The fan may re-
start several times until finally 
switching off. 
Never interrupt the mains 
connection before the entire 
cool-down phase comes to an 
end (except in emergency  
situations).
Damage caused to the device 
by overheating renders the 
guarantee null and void. 

NOTE

4.  In the case of longer down   
  times, lock the closing lid of   
  the exhaust connection.

Shutting Down the Unit

Heating with a room 
thermostat 

(accessories)

The devices operate fully auto-
matically depending on the room 
temperature.

1.  Remove jumper plug 2.

2.  Connect plug 3 of the room   
  thermostat 4 to the thermostat 
   socket 1 at the switch cabinet.

3.  Place the room thermostat 4 at  
  a suitable location in the room. 
  The thermostat sensor must not  
  be within the hot air stream   
  and  should also not be placed  
  on a cold floor. 
 
4.  Set the required temperature on  
  the room thermostat 4. 
 
 

 
 
 
 

5.  Turn the operating switch to the 
   required operation position 
   “1” (low heating stage) or  
  “2” (high heating stage). 

If heat is required and after a brief 
initial ventilation of the burner the 
device switches on and continues 
to run completely automatically.

1.  Turn the operating switch to  
  the „0“ position (off).

2.  Close off the  
  fuel supply at  
  the device and  
  oil tank.

3.  In case of longer downtimes, 
  disconnect the device from the  
  power supply.

4

3

1

Summary of Contents for HTL 400

Page 1: ...Oil red Heating Centers Operation Technology REMKO HTL 400 Edition GB R11...

Page 2: ......

Page 3: ...antee 15 Environmental Protection and Recycling 15 Wiring diagram 16 Maintenance Log 18 Technical data 19 Made by REMKO Before commissioning use of the device these operating instructions must be read...

Page 4: ...he device always observe the respective local construc tion and re protection ordinances as well as the regulations of the employers liability insurance association Description of Device Mobile fuel t...

Page 5: ...matically This process may repeat itself several times Monitoring operation of the device All functions of the device are monitored safely and fully auto matically by the thermostat of the three fold...

Page 6: ...The provision of adequate safety clearance The function Room heating open blown or ducted low pressure or high pressure in the set up room General aspects Heat requirement room temperature nominal air...

Page 7: ...est performed using pipes or special hot air or lm hoses The lengths possible are dependent upon re sistance provided by the air ducting in use When using hot air hoses the following points must be ta...

Page 8: ...the seams of the hot air tubes must point in the direction of the air ow Secure fastening of the tubes and pipes at the exhaust and any connection points used must be observed Only suitable air diffus...

Page 9: ...o preclude errors in measurement each phase conductor and fan stage must be tested separately 2 The setting of the thermal over load relay should be performed as follows Stage 1 6 7 A Stage 2 17 0 A 3...

Page 10: ...c rotation direction monitor for the fan motor NOTE The electrical connection of the device must be performed at a dedicated supply point with an earth leakage circuit breaker in compliance with VDE 0...

Page 11: ...ccessories The devices operate fully auto matically depending on the room temperature 1 Remove jumper plug 2 2 Connect plug 3 of the room thermostat 4 to the thermostat socket 1 at the switch cabinet...

Page 12: ...e Keep the device free of dust and any deposits of dirt Only clean the device with a dry or damp cloth Do not apply any direct water spray e g high pressure hoses etc Do not use abrasive or cleaning s...

Page 13: ...screws to the unit housing Pay attention to the OBEN UP HAUT label 3 Tighten the 2 upper fastening screws 4 Tighten the 2 lower fastening screws only lightly so that the burner ange can be pulled toge...

Page 14: ...the sensors and capillary tubes of the safety devices for damage or dirt 7 Check that the temperature monitor TW for correct func tion using appropriate means 8 Check the forced air burner for possib...

Page 15: ...packaging material at the corres ponding disposal sites Disposal of the old device Manufacture of our equipment is subject to constant quality control Only high quality materials that are recyclable t...

Page 16: ...16 REMKO HTL 400 We reserve the right to make changes in dimensions and design in the interest of technical advance Wiring diagram...

Page 17: ...17 When ordering spare parts always list the EDP no as well as the device no and device type see the type plate Wiring diagram...

Page 18: ...set by authorised expert personnel in accordance with legal speci cations 1 BImSchV An appropriate test log must be kept Maintenance work may only be performed on the forced air burner by authorised e...

Page 19: ...1 Stage kW 245 Ventilating performance max 1 2 Stage m3 h 25000 Ventilating performance max 1 1 Stage m3 h 16600 Pressure max total 2 Stage Pa 1000 Pressure max total 1 Stage Pa 500 Fuel EL heating o...

Page 20: ...ultants is always up to date This has given us the reputation of being more than just a good reliable supplier REMKO a partner that helps solve problems Sales REMKO not only provides an extensive sale...

Reviews: