![REMKO HTL 150-FB Operation,Technology,Spare Parts Download Page 9](http://html1.mh-extra.com/html/remko/htl-150-fb/htl-150-fb_operation-technology-spare-parts_1438983009.webp)
9
Technical Data
Series
HTL 150-FB
2-step
HTL 200-FB
2-step
HTL 250-FB
2-step
rated heat power max.
kW
125 / 160
150 / 200
160 / 220
rated heat output
kW
115 / 148
138 / 184
148 / 203
rated air current
1)
m³/h
7.890 / 11.180
9.120 / 12.950
9.780 / 13.860
pressure
(max. entirely)
Pa
190 / 410
480 / 540
540 / 620
fuel
heating oil EL according to DIN 51603 / diesel
fuel consumption max.
kg/h
10,5 / 13,5
12,6 / 16,8
13,5 / 18,0
nozzle
USG
2,75 80°S
3,5 80°S
3,5 80°S
pump pressure ca. (1. step / 2. step)
bar
10 / 17
9 / 16
10 / 18
flue gas loss min.
%
8
8
9
chamber resistance (in operation)
Pa
65
110
135
essential flue
Pa
0
0
0
electrical connection
V/Hz
400/3N~ / 50
400/3N~ / 50
400/3N~ / 50
power take-up (max. entirely unit)
W
2.640
4.580
4.810
rated current (max. entirely unit)
A
6,1
9,3
9,8
power take-up (min / max. fan)
W
960 / 1.950
2.700 / 3.900
2.850 / 4.100
rated current (max. fan)
A
3,6
6,8
7,1
power take-up (oil preheater)
W
300
300
300
fuse protection (required)
A
3 x 16
3 x 16
3 x 16
rise in temperature (
D
t
)
K
56
57
59
sound pressure level L
pA
1m
2)
dB (A)
69 / 71
70 / 74
70 / 74
air inlet ø (air suction socket, Accessories)
mm
550
550
600
air outlet ø
mm
550
550
550
waste gas connection ø
mm
200
200
200
length ges.
mm
2.400
2.400
2.400
width ges.
mm
800
800
800
height ges.
mm
1.370
1.370
1.370
weight (with burner)
kg
460
480
505
We reserve the right to make modifications in dimensions and construction in the interests of technical progress.
1)
D
t
45K / 1,2 kg/m³
2) noise level measurement acc. to DIN 45635 - 01 - KL 3