6.
If regulation of the bypass is insufficient,
move the rotary regulator to the position that
enables the desired temperature to be
reached. Even if the rotary regulator was to
be destroyed manually, the bypass still limits
the inlet temperature.
4.6 Installation of the actuator for
the pump group HGM
The Actuator for the pump group is delivered with
the components shown in the diagram.
2
4
3
5
1
Fig. 9: Installation of the actuator
1: Actuator
2: Ring with scale
3: Adapter for the mixing valve
5: Screw for fixing the drive
1.
The ring with scale (2) is the reference point
for the hot water proportion and must be
aligned as shown in the right picture of the
following diagram.
2
2.
Insert the correctly-aligned ring (2) into the
guide of the actuator (1).
8
1
3.
Press and turn the rotary knob of the actuator
fully in a clockwise direction and then release
it.
4.
Insert the adapter and screw in the locking
screw.
REMKO PUMP GROUPS HGM / HGU
18