  "TIMER" Button

Press this button to activate the 
automatic switch-on/off time 
for the equipment. Buttons   
and   are used to program 
these times at 10 minute 
intervals.

  "

Button

This button increases the value 
when setting the clock or timer.

  "

Button

This button decreases the value 
when setting the clock or timer.

 

"SET" Button

Press this button to activate the 
previously set timer.

 

"

OFF  " Button

Press this button to activate a 
switch-off timer of 1/2, 1, 2 or 
5 hours.

 

"

TURBO" Button

Press this button to activate 
maximum fan speed for 30 
minutes.

  "CLOCK" Button

Press this button to activate 
clock setting mode.

   

"

DISP" Button

Press this button to send the 
current temperature of the 
remote control to the indoor 
unit using the I-Feel function.

 

"

ION" Button

Press this button to switch on 
the ion generator.

  1. Automatic mode  

In this mode the equipment is 
running in cooling mode.

  2. Cooling mode 

 

In this mode the room air is 
cooled to the preset target 
temperature.

  3. Heating mode 

Heating mode is not supported.

 

4. Circulation mode
In this mode the room air is 
circulated.

 

5. Dehumidifying mode
In this mode the room is 
mainly dehumidified, the set 
temperature is maintained.

  "FAN" Button

Press this button to set the 
required fan speed. 4 levels 
are available: Automatic, high, 
medium and low fan speed.

 

"

I FEEL" Button

Press this button to change 
the point of room temperature 
measurement to the remote 
control.  
The temperature measured 
by the remote control is then 
sent at regular intervals to the 
indoor unit.

  "

"

 (SLEEP) Button

Press this button to activate 
sleep mode. In cooling mode, 
the target temperature is 
automatically raised by 1 
°C after 1 hour.

 

After the 

2nd hour, the temperature 
automatically increases/
reduces by 2°C. This function 
deactivates itself after 6 hours.

  "   " (SWING) Button

This button activates the 
oscillating fin function 
to provide improved air 
distribution in the room.

Buttons on the remote control

Buttons on the remote control

  "ON/OFF" Button

Press this button to start the 
equipment. 

  "

Button

Press this button to reduce the 
desired temperature to a value 
as low as 16 °C. 

  "

Button

Press this button to increase the 
desired temperature to a value 
as high as 30 °C. 

 

"

MODE" Button

Press this button to select the 
operating mode. The indoor unit 
has 5 modes:

7

Summary of Contents for ATY 261

Page 1: ...Edition GB U01 REMKO ATY ATY 261 ATY 351 Wall mounted air conditioning unit Operation Technology Spare parts...

Page 2: ......

Page 3: ...onmental protection and recycling 4 Warranty 4 Transportation and packaging 5 Description of the equipment 5 Combinations 5 Operation 6 13 Shutdown 14 Care and maintenance 14 15 Troubleshooting and cu...

Page 4: ...kept a safe distance from inflammable explosive combustible agressive and dirty areas or atmospheres Persons coming into contact with equipment parts may suffer burns or injury Installation repair an...

Page 5: ...infrared remote control The indoor unit comprises a finned vaporiser vaporiser fan controller and condensation tray The indoor unit may be used in conjunction with REMKO outdoor components that provi...

Page 6: ...shooting and customer service CAUTION Infrared remote control Immediately replace flat batteries with a new set otherwise there is a risk of leakage It is recommended that the batteries are removed i...

Page 7: ...ode the room air is circulated 5 Dehumidifying mode In this mode the room is mainly dehumidified the set temperature is maintained FAN Button Press this button to set the required fan speed 4 levels a...

Page 8: ...nly supported in cooling mode In automatic mode press the button to reduce the fixed temperature from 24 C by 1 or 2 C press the button to increase it by 1 or 2 C The current setting is displayed next...

Page 9: ...room air If the actual temperature falls approx 0 5 C below the set room temperature the controller switches the cooling off In order to protect the compressor the controller will only switch the coo...

Page 10: ...function The swing function improves air circulation in the room SWING Button hidden SWING SWING SWING Press this button to set the fan speed One can choose between low medium high and automatic fan s...

Page 11: ...ch on switch off timer The switch on off time will flash The Timer symbol on the indoor unit is lit Press the and buttons to set the desired switch on off time If set successfully the Timer symbol wil...

Page 12: ...tching off the unitPress several times to set the timer to 30 minutes 1 hour 2 hours 3 hours or 5 hours The current time is replaced by the remaining time OFF OFF OFF Press this button to increase the...

Page 13: ...temperature remains unchanged DISP Button hidden DISP C C The unit includes an ion generator for generating negative ions High levels of negative ions may be found in mountain regions near waterfalls...

Page 14: ...ing a damp cloth Do not use any caustic abrasive or solvent based cleaning products Do not use a jet of water Clean the fins on the unit prior to long shutdown periods Maintenance It is recommended th...

Page 15: ...manual 1 Open front cover 5 Cleaning with lukewarm water 3 Press up the flaps on the filter and pull it down and out by the flaps Fig 3 4 Clean the filter using a normal vacuum cleaner The dirty side...

Page 16: ...he receiver or transmitter unit in the shade Electromagnetic fields are interfering with transmission Does it function when switching off possible sources of interference Signal is not transmitted whe...

Page 17: ...0 proceed to step 5 4 If digit I is 1 press the Programming E7 Digit I Digit II Digit III Digit IV Digit V Digit VI is displayed before continuing with the programming procedure 10 Point the transmit...

Page 18: ...frigerant pipes injection and suction pipe valves and connections to make them tight against vapour diffusion If necessary also insulate the condensation pipe Select an installation location which all...

Page 19: ...board Fig 9 5 If necessary remove the break outs on the housing 6 Fit the unit to the wall 7 Connect the refrigerant pipes electrical cables and condensation pipe to the indoor unit as described belo...

Page 20: ...directly into a sewer pipe fit a trap to prevent any unpleasant odours When operating the unit at outdoor temperatures below 0 C ensure the condensation pipe is laid to protect it against frost If nec...

Page 21: ...junction with the unit it may be necessary to install an additional relay with a higher contact rating after the switch off contact on the pump to switch off the compressor Connecting the indoor unit...

Page 22: ...motor Front 2 CN 6 CN 8 CN 9 CN 10 CN 11 CN 1 CN 4 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 1 2 3 N2 1N 2 3 4 5 CN...

Page 23: ...rt and check the safety functions 4 Check the indoor unit control system using the functions described in the chapter Operation Timer temperature setting fan speeds and switching to ventilation or deh...

Page 24: ...view ATY 261 ATY 351 4 15 3 1 2 5 5 14 6 7 8 14 11 10 12 16 9 7 7 13 17 We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process REM...

Page 25: ...motor set 1107404 1107404 6 Swing motor 1107405 1107405 7 Outlet fins set 1107406 1107406 8 Condensation tray 1107439 1107439 9 Finned vaporiser 1107408 1107409 10 Fan wheel vaporiser 1107410 1107410...

Page 26: ...410 440 Noise output per stage 3 dB A 33 36 40 35 37 41 Voltage supply V Hz 230 1 50 Protection degree IP X0 Nom electrical power consumption cooling 1 kW 0 03 0 04 Nom current consumption cooling 1 A...

Page 27: ...Notes...

Page 28: ...ts in the areas of air conditioning and heating technology Customer service Our equipment is precise and reliable However should a fault should occur REMKO customer service is quickly at your side Our...

Reviews: