REMKO ATY 261 Operation,Technology,Spare Parts Download Page 6

The indoor unit is easy to operate using an infrared remote control. This is supplied as standard. 
The indoor unit beeps to acknowledge the correct transmission of data.
If it is not possible to program the indoor unit using the remote control, it can also be manually operated.

Display on indoor unit

The display is lit according to the 
settings.

The infrared remote control can 
send the programmed settings 
from a distance of 6 m to the 
receiver on the indoor unit. 
Data will only be received correctly 
if the remote control is pointed 
at the receiver and no objects are 
obstructing the transmission path.

First of all, insert the batteries 
(two type AAA) supplied with the 
remote control. 
Remove the cover on the battery 
compartment and insert the 
batteries. Take into account the 
correct polarity (see markings).

Operation

Errors are displayed in coded 
format (see chapter on 
trouble-shooting and customer 
service).

      CAUTION

Infrared remote control

Immediately replace flat 
batteries with a new set, 
otherwise there is a risk of 
leakage. It is recommended 
that the batteries are removed 
if the equipment is shut down 
for long periods

      NOTE

Manual operation

The indoor unit can also be started 
manually. Press the button on 
the right of the unit to activate 
automatic mode.

The following settings apply to 
manual mode:

Automatic mode: 
above 21 °C = cooling mode, 
set temperature 24 °C 
fan speed AUTO

Pressing any button on the infrared 
remote control interrupts manual 
operation.

Max. distance 6 m

max. 6 m

Display on indoor unit

Power  

Unit switched on

Circulation mode 

active

Timer mode

Fan speed 

Levels 1, 2 and 3 and 

Auto (flashing)

Display 

Used to display 

coded error 

messages, room 

and target 

temperature

C

TURBO

SET

Ion generator  

switched on

Help save on energy consump-
tion in stand-by mode! If the 
device, system or component 
is not in use, we recommend 
disconnecting the power sup-
ply. Components with a safety 
function is excluded from our 
recommendation!

      TIP

REMKO ATY

6

Summary of Contents for ATY 261

Page 1: ...Edition GB U01 REMKO ATY ATY 261 ATY 351 Wall mounted air conditioning unit Operation Technology Spare parts...

Page 2: ......

Page 3: ...onmental protection and recycling 4 Warranty 4 Transportation and packaging 5 Description of the equipment 5 Combinations 5 Operation 6 13 Shutdown 14 Care and maintenance 14 15 Troubleshooting and cu...

Page 4: ...kept a safe distance from inflammable explosive combustible agressive and dirty areas or atmospheres Persons coming into contact with equipment parts may suffer burns or injury Installation repair an...

Page 5: ...infrared remote control The indoor unit comprises a finned vaporiser vaporiser fan controller and condensation tray The indoor unit may be used in conjunction with REMKO outdoor components that provi...

Page 6: ...shooting and customer service CAUTION Infrared remote control Immediately replace flat batteries with a new set otherwise there is a risk of leakage It is recommended that the batteries are removed i...

Page 7: ...ode the room air is circulated 5 Dehumidifying mode In this mode the room is mainly dehumidified the set temperature is maintained FAN Button Press this button to set the required fan speed 4 levels a...

Page 8: ...nly supported in cooling mode In automatic mode press the button to reduce the fixed temperature from 24 C by 1 or 2 C press the button to increase it by 1 or 2 C The current setting is displayed next...

Page 9: ...room air If the actual temperature falls approx 0 5 C below the set room temperature the controller switches the cooling off In order to protect the compressor the controller will only switch the coo...

Page 10: ...function The swing function improves air circulation in the room SWING Button hidden SWING SWING SWING Press this button to set the fan speed One can choose between low medium high and automatic fan s...

Page 11: ...ch on switch off timer The switch on off time will flash The Timer symbol on the indoor unit is lit Press the and buttons to set the desired switch on off time If set successfully the Timer symbol wil...

Page 12: ...tching off the unitPress several times to set the timer to 30 minutes 1 hour 2 hours 3 hours or 5 hours The current time is replaced by the remaining time OFF OFF OFF Press this button to increase the...

Page 13: ...temperature remains unchanged DISP Button hidden DISP C C The unit includes an ion generator for generating negative ions High levels of negative ions may be found in mountain regions near waterfalls...

Page 14: ...ing a damp cloth Do not use any caustic abrasive or solvent based cleaning products Do not use a jet of water Clean the fins on the unit prior to long shutdown periods Maintenance It is recommended th...

Page 15: ...manual 1 Open front cover 5 Cleaning with lukewarm water 3 Press up the flaps on the filter and pull it down and out by the flaps Fig 3 4 Clean the filter using a normal vacuum cleaner The dirty side...

Page 16: ...he receiver or transmitter unit in the shade Electromagnetic fields are interfering with transmission Does it function when switching off possible sources of interference Signal is not transmitted whe...

Page 17: ...0 proceed to step 5 4 If digit I is 1 press the Programming E7 Digit I Digit II Digit III Digit IV Digit V Digit VI is displayed before continuing with the programming procedure 10 Point the transmit...

Page 18: ...frigerant pipes injection and suction pipe valves and connections to make them tight against vapour diffusion If necessary also insulate the condensation pipe Select an installation location which all...

Page 19: ...board Fig 9 5 If necessary remove the break outs on the housing 6 Fit the unit to the wall 7 Connect the refrigerant pipes electrical cables and condensation pipe to the indoor unit as described belo...

Page 20: ...directly into a sewer pipe fit a trap to prevent any unpleasant odours When operating the unit at outdoor temperatures below 0 C ensure the condensation pipe is laid to protect it against frost If nec...

Page 21: ...junction with the unit it may be necessary to install an additional relay with a higher contact rating after the switch off contact on the pump to switch off the compressor Connecting the indoor unit...

Page 22: ...motor Front 2 CN 6 CN 8 CN 9 CN 10 CN 11 CN 1 CN 4 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 1 2 3 1 2 3 N2 1N 2 3 4 5 CN...

Page 23: ...rt and check the safety functions 4 Check the indoor unit control system using the functions described in the chapter Operation Timer temperature setting fan speeds and switching to ventilation or deh...

Page 24: ...view ATY 261 ATY 351 4 15 3 1 2 5 5 14 6 7 8 14 11 10 12 16 9 7 7 13 17 We reserve the right to modify the dimensions and constructional design as part of the ongoing technical development process REM...

Page 25: ...motor set 1107404 1107404 6 Swing motor 1107405 1107405 7 Outlet fins set 1107406 1107406 8 Condensation tray 1107439 1107439 9 Finned vaporiser 1107408 1107409 10 Fan wheel vaporiser 1107410 1107410...

Page 26: ...410 440 Noise output per stage 3 dB A 33 36 40 35 37 41 Voltage supply V Hz 230 1 50 Protection degree IP X0 Nom electrical power consumption cooling 1 kW 0 03 0 04 Nom current consumption cooling 1 A...

Page 27: ...Notes...

Page 28: ...ts in the areas of air conditioning and heating technology Customer service Our equipment is precise and reliable However should a fault should occur REMKO customer service is quickly at your side Our...

Reviews: