Technical Data 

Type 

  ATR-4 

Temperature range 

  + 5... + 40 °C 

Temperature cooling 

  2... 10 K, adjustable 

Temperature sensor 

  NTC (internal) 

or 

  KTY (external) 

Sensor tolerance 

  ± 1 K 

Activation difference 

  ± 0,1... ± 3,0K, adjustable 

Proportional control 

  1...10 K, adjustable 

Pulse duration 

  1...15 min, adjustable 

Temperature activation 

  Target value 0.5 K 

 

  Current value 0.1 K 

Target temperature setting 

  Rotating knobs 

Program points 

  16 

Clock timer 

  Electronic weekly clock timer 

Power reserve 

1)

 

  approx. 15 minutes 

Display 

  LC display 

Operating current 

  230 V AC (± 10%) 

Power consumption 

  approx. 2VA 

Relay contact 

  1 isolated change-over contact 

Max. supply of switch current 

  10(4)A, 230 V AC 

Electrical connections 

  Screw terminals 

Electrical lifespan 

  0.5 x 10

operating cycles 

Max. ambient temperature 

  0...+ 50 °C 

Storage temperature 

  - 10... + 70 °C 

Housing:        Material 

  plastic 

                      Protection type 

  IP 20 

                      Protection class 

  II in accordance with DIN EN 60335-1 

                      Dimen. W x H x D 

  132 x 82 x 32 mm  

                      Attachment 

  Wall-mounted  

                      Weight 

  approx. 250 g  

 

 

 

Ref. No. 

 

1011340 

1)

 

The power reserve only refers to the time.  

    All other parameters remain permanently saved

Summary of Contents for ATR-4

Page 1: ...REMKO ATR 4 Electronic Clock Thermostat Edition GB H12 Operation Technology Original REMKO REMKO powerful like a bear...

Page 2: ......

Page 3: ...are made to the supplied unit Electronic Clock Thermostat REMKO ATR 4 Important Always keep these operating instructions near or on the unit Contents Page Functionality 4 Operating Controls 4 Comfort...

Page 4: ...left hand side of the display shows the operating mode Comfort Temperature The desired comfort temperature 5 to 40 C is set on the upper rotating knob 2 It is displayed on the right hand side of the...

Page 5: ...ed on the right hand side of the display The unit continues to record the current temperature but all control functions are completely switched off Hand Button The button makes it possible to change t...

Page 6: ...again Selecting the Operating Mode The main operating modes are selected by pressing one of the three program buttons on the left You can select from the following modes Automatic Comfort continuous...

Page 7: ...fect When you press the SET program button you are taken to the desired set ting option Program point number Time Day Temperature mode Each selected setting option blinks on the display By pressing th...

Page 8: ...you press the PROG program button for 6 seconds you are taken to a menu where various basic functions can be set The functions are shown on the left hand side of the display and the corresponding val...

Page 9: ...eating Co cooling 2PPu 2 point Pulsating function display When the control function is switched from 2 point to pulse and vice versa this results in the corresponding parameters being calculated on th...

Page 10: ...nductors from becoming loose that meets the requirements of EN 60730 Part 1 This can be achieved for example by securing the lines with cable bindings Compliance with VDE 0100 EN 60730 Part 1 as well...

Page 11: ...of the housing If the entire panel is removed it is possible that the housing no longer com pletely closes M O DI M I DO F R SASO M O DI M I DO F R SASO G Note The electronic clock thermostat must be...

Page 12: ...REMKO heater is made at terminals 1 and 3 For cooling units to terminals 1 and 2 G Caution There must be a power current of 230 V 50 Hz at terminals 6 and 7 at all times for the unit to function We re...

Page 13: ...P15 P16 The following tables can be used to enter individual customer data Customer Data Timer program Control parameters Activation difference or Proportional control Pulse duration Functions Sensor...

Page 14: ...timer Power reserve 1 approx 15 minutes Display LC display Operating current 230 V AC 10 Power consumption approx 2VA Relay contact 1 isolated change over contact Max supply of switch current 10 4 A 2...

Page 15: ......

Page 16: ...REMKO GmbH Co KG Klima und W rmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 E Mail info remko de Internet www remko de...

Reviews: