Spare Part List  

No.  Description 

Ref-No.

 

inspection cover 

1103701 

exhaust connection 

1103702 

inspection cover 

1103703 

gasket (inspection cover) 

1103705 

combustion chamber 

1103704 

blow-out connection 

1103706 

housing base 

1103707 

cover (filler neck) 

1102925 

fuel hose (running metres) 

1102156 

10 

fuel filter 

1102146 

11 

protective socket, small 

1102131 

12 

side cover, left 

1103708 

13 

fastening screw 

1102937 

14 

cover, front / back 

1103709 

15 

side cover, right 

1103710 

16 

safety temperature limiter  

1103711 

17 

filler cap 

1102148 

18 

fuel filter (filler neck) 

1102149 

19 

hose clamp 

1102157 

20 

fuel tank cpl. (with tank heating) 

1103727 

21 

transport handle, front 

1102932 

22 

drain screw 

1102152 

23 

gasket ring (drain screw) 

1102151 

24 

wheel cap 

1101623 

25 

wheel lock ring 

1101622 

26 

wheel 

1102155 

27 

transport handle, back 

1102931 

28 

connecting cable with plug 

1101320 

29 

automatic burner relay 

1102239 

30 

PG-plate 

1102533 

31 

locking screw (PG-plate) 

1103716 

32 

relay socket 

1102534 

33 

protective socket 

1101528 

34 

operating switch 

1102248 

35 

cover  

1103713 

36 

mounting plate 

1103714 

37 

auxiliary relay 

1102137 

38 

terminal strip 12 x 

1103715 

39 

ignition cable, kit 

1102159 

40 

ignition electrode 

1102132 

41 

traction relief 

1108325 

No.  Description 

Ref-No. 

42 

thermostat socket 

1101018 

43 

bridge circuit plug 

1101019 

44 

protective socket, big 

1101615 

45 

capacitor 

1102907 

46 

connection cable (solenoid valve) 

1102825 

47 

hose connection fitting 

1102109 

48 

fuel pump (with solenoid valve) 

1103717 

49 

copper pipe 4 mm, cpl. 

1102315 

50 

angle clutch 1/8“ x 4 

1102112 

51 

solenoid valve 

1103718 

52 

pump clutch 

1102936 

53 

fan motor 

1102905 

54 

fan housing 

1103719 

55 

photo cell holder 

1102126 

56 

photo cell 

1108209 

57 

fan blade 

1103720 

58 

protecting grille 

1103721 

59 

clamp (ignition electrode) 

1102120 

60 

ignition electrode 

1102118 

61 

protection hose 

1101617 

62 

angle clutch 

1102116 

63 

cutting ring 4 mm 

1102908 

64 

sleeve nut 4 mm 

1102909 

65 

connection pipe 

1102117 

66 

air slide plate 

1103722 

67 

holder (nozzle) 

1102121 

68 

nozzle 

1102923 

69 

air flow plate 

1102122 

70 

burner head 

1103723 

71 

recool thermostat 

1101027 

72 

distance sleeve  

1103724 

73 

clamp (thermostat) 

1102128 

74 

electric board cpl. (slide in) 

1103726 

75 

cover (tank heating) 

1102258 

76 

tank heating cpl. 

1102256 

 

 

 

Not 

cover gasket (fuel pump) 

1108454 

shown  fuel filter (pump) 

1108409 

 

plastic screw (pump) 

1103725 

 

fuel filter with shut-off valve (2 pipes)  1102526 

 

thermostat plug 

1101020

 

When ordering spare parts please indicate ref.-no. and machine no. (see type plate)!

 

Summary of Contents for AT 25

Page 1: ...REMKO powerful like a bear Edition GB M04 Operation Technology Spare Parts REMKO AT 25 Automatic oil heater ...

Page 2: ......

Page 3: ...10 Wiring diagram 10 Troubleshooting 11 Exploded view 12 Spare part list 13 Maintenance log 14 Automatic oil heater REMKO AT 25 Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes or maintained incorrectly etc or if it is changed without our prior consent Subject to a...

Page 4: ...rner with optical flame monitoring a low mainte nance axial ventilator a connection cable with plug a room thermostat socket and a fivefold filter system The unit complies with the basic safety and health re quirements of the relevant EU stipulations and is reli able and simple to operate The unit can be used e g in the following areas for drying new buildings for point heating of outdoor workplac...

Page 5: ...nd doors or openings which are not lockable are present in the region of ceiling and floor for the air supply and for out going air and the size of these openings in m corresponds with at least 0 003 times the nominal heat output in kW of all units operating in the room 2 6 The unit must not be installed or operated in rooms and areas where the danger of fire or explosion ex ists 3 Room drying 3 1...

Page 6: ...he units are generally to be operated in accordance with the safety rules the building code of the land con cerned and the fire protection code Avoid under or overpressure in the room where the unit is installed as this would result in combustion troubles Suction and blow out cross sections may not be re duced It is prohibited to connect conduits or hoses to the unit blow out opening Make sure tha...

Page 7: ...It is not possible to get rid of paraffin discharge which is already present using the tank heating The requirement for this is the cleaning of the entire fuel system G The unit is to be installed only in well aerated rooms but not in living rooms or similar recreation rooms 1 Put operating switch 1 into 0 position OFF 2 Connect unit plug to a suitable mains socket 230V 1 50 Hz Connect the unit wi...

Page 8: ...e a long service life and trouble free operation After each heating period or even earlier depending on the deployment conditions the entire unit including combustion chamber and burner head must be cleaned of soot sediments dust and dirt The oil filters must also be cleaned replaced at least once a year or depending on the degree of contamina tion of the fuel frequently G Setting and maintenance ...

Page 9: ...ustment of air slide plate Fine adjustment of air slide plate by means of CO2 indi cator and soot pump CO2 value approx 10 13 Soot figure 0 1 by Bacharach 4 When maintenance has been carried out re assemble all parts carefully in reverse order 5 Pre set air flow plate air slide plate and the ignition electrode distance according to the approximate indi cations 4 2 3 4 8 air slide plate air flow pl...

Page 10: ...re counter clockwise reduce the pressure The required pump pressure is determined according to the heating capacity please refer to unit type plate and to the nozzle size The pressure setting screw A is to be secured with the counter nut B after having set the pressure Fuel Pump The standard type of the pump runs in a system of 1 pipe The required fuel is sucked in through the suction line S For t...

Page 11: ...f ignition electrodes or damaged insulation Adjust correctly resp replace it 13 Air flow plate of the burner head is misadjusted resp dirty Adjust correctly by means of CO2 indicator and soot pump CO2 10 13 and soot figure by Bacharach 0 1 14 Solenoid valve does not open Check solenoid valve resp replace if necessary A click should be heard during switching on off The safety temperature limiter ha...

Page 12: ...12 Exploded View We reserve the right to make modifications in dimensions and construction in the interests of technical progress See fig A See fig B Fig A Fig B 74 ...

Page 13: ...ition cable kit 1102159 40 ignition electrode 1102132 41 traction relief 1108325 No Description Ref No 42 thermostat socket 1101018 43 bridge circuit plug 1101019 44 protective socket big 1101615 45 capacitor 1102907 46 connection cable solenoid valve 1102825 47 hose connection fitting 1102109 48 fuel pump with solenoid valve 1103717 49 copper pipe 4 mm cpl 1102315 50 angle clutch 1 8 x 4 1102112 ...

Page 14: ...ing screws Electric safety inspections Test run Maintenance Log Model Model No Setting and maintenance work is to be carried out only by authorised specialists Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature Signature Signature 6 Date 7 Date 8 Date 9 Date 10 Date Signature Signature Signature Signature Signature 11 Date 12 Date 13 Date 14 Date 15 Date Signature Signature S...

Page 15: ......

Page 16: ...REMKO GmbH Co KG Klima und Wärmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 ...

Reviews: