REMKO ASF 100 Operation Technology Spare List Download Page 9

9

1.  Remove the cover [F] from 

the rear wall of the unit with a 

suitable tool. 

2.  A suitable drainage hose of 

sufficient length can be routed 

to the outside through the free 

opening. 

The condensate must preferably 

be discharged to a lower located 

outlet in unsupervised continuous 

duty.  

When using an external container 

(tub, bucket, etc.) the unit must be 

placed in a raised position.

Decommissioning

ATTENTION

It must be ensured that the 
drainage house is routed to the 
drain with a gradient to ensure 
that the condensate is able to 
flow out freely!

Unit transport

F

Switch off the unit with 
the ON/OFF button on 
the control panel.

The mode LED extinguishes. The 
unit initially switches off com-
pletely after lapse of a preset after-
running time of 2 minutes. 

If the units are not 
used for extended 
periods of time,  
they must be  
disconnected from  
the power supply.

The condensate container must be 
emptied completely and dried with 
a clean cloth.  

Pay attention to subsequently 
dripping condensate!

 

Prior to possible storage, the units 
must be cleaned thoroughly and 
dried.

For storage purposes, the units 
should be covered with plastic 
sheeting and stored in an upright 
position in a protected and dry 
location.

The units must only be stored 
in upright in a suitable location 
protected from dust and direct 
sunlight. 

ATTENTION

Never disconnect the unit 
from the power supply during 
operation by pulling out the 
mains plug. This can damage 
the control electronics. 

Dam-

age of this kind is not covered 
by the warranty

.

F

The units are provided with a 
handle for easy and convenient 
transport. 

   The unit must be switched off 

and the plug removed from the 
power socket each time before 
the unit is moved to a different 
location.

   The condensate container must 

be emptied completely.

 

  As long as residual moisture is 

still present in the unit or water 
is present in the condensate 
container, the units must only be 
transported upright.

NOTE

Attention must be paid to 
dripping condensate. 
Condensate can still drip after 
switching off the unit. 

ATTENTION

The power cord must never 
be used for pulling or fixing 
purposes.

Summary of Contents for ASF 100

Page 1: ...Edition GB T12 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation Technology Spare parts...

Page 2: ......

Page 3: ...allation or on the unit Subject to changes errors and typographical errors excepted Unit description 4 Installation 5 Safety information 6 Commissioning 6 Decommissioning 9 Unit transport 9 Care and m...

Page 4: ...ed The units return to the previously selected mode In an unsupervised continuous mode with external condensate connection the produced condensate is continuously drained via a hose connection on the...

Page 5: ...on is achieved when the units are installed about 1 m above the ground The room to be dried or dehu midified must always be closed from the ambient atmosphere Open windows doors etc as well as frequen...

Page 6: ...the switch off timer for 2 4 or 8 hours AUTO SWING This button is used to activate the automatic swing mode of the air directing flap IONIC This button is used to switch on the ioniser for enriching...

Page 7: ...ted mode MODE IONIC and AUTO SWING is active when the unit is switched on NORMAL This is the comfort mode The unit regulates according to time 12 hours or on reaching the preset humidity the dehu midi...

Page 8: ...g etc IONISER The unit has an ioniser genera tor for the generation of negative ions A high concentration of negative ions occurs e g in mountainous regions at waterfalls and in forests and the air we...

Page 9: ...tion to subsequently dripping condensate Prior to possible storage the units must be cleaned thoroughly and dried For storage purposes the units should be covered with plastic sheeting and stored in a...

Page 10: ...the plug from the power socket 3 Pull the air inlet grille out of the unit at the recessed grip G ATTENTION The units must not be used without air inlet grille fitted G All moving parts are provided...

Page 11: ...The FULL TANK indicator light must not light up Check the microswitch of the condensate container Check for free air flow Overheating Check the miniature fuse on the control pcb The unit operates but...

Page 12: ...operated by suitably trained persons who are familiar with the operation of the unit The manufacturer is not liable for any damage attributed to failure to observe the manufacturer s instructions or...

Page 13: ...13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Type of unit Serial number 1 2 3 4 5 6 7 8 9 10...

Page 14: ...nt Heating element Thermal fuse Rear Heating element Heating element Transformer Output Transformer Input Control panel Thermostat Heating element Fan Circulation air Fan Regeneration circuit Adsorpti...

Page 15: ...output l day 8 7 at 20 C 70 relative humidity l day 8 0 at 15 C 60 relative humidity l day 7 0 Max air volume flow m3 h 150 Condensate container capacity Litre 3 0 Power supply V 230 1 Frequency Hz 50...

Page 16: ...to date This has given us the reputation of being more than just a good reliable sup plier REMKO a partner that helps solve problems Sales REMKO not only has an extensive sales network in Germany and...

Reviews: