REMKO ASF 100 Operation Technology Spare List Download Page 16

Subject to technical changes, err

ors and omissions excepted!

REMKO EUROpE-wIDE

... and somewhere near you! 
Take advantage of our experience and consulting services

REMKO GmbH & Co. KG 
Klima- und Wärmetechnik

Im Seelenkamp 12   D-32791 Lage

P.O. Box 1827 ·D-32777 Lage

Telephone  

+49 5232 606-0

Fax    

+49 5232 606-260

E-mail   

[email protected]

Internet  

www.remko.de

Consulting

Through intensive training, we en-
sure that the expert knowledge of our 
consultants is always up-to-date. This 
has given us the reputation of being 
more than just a good, reliable sup-
plier: REMKO, a partner that helps solve 
problems.

 

 
Sales

REMKO not only has an extensive sales 
network in Germany and abroad, but 
also unusually highly qualified sales 
experts.  
REMKO field representatives are more 
than just salesmen. They must also be 
customer consultants in air conditioning 
and heating technology.

 

 
Customer service

Our units operate precisely and reliably. 
If a fault should occur, REMKO Custom-
er Service is there to help you. Our ex-
tensive network of experienced specialist 
retailers guarantees our customers a fast 
and reliable service at all times.

Summary of Contents for ASF 100

Page 1: ...Edition GB T12 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation Technology Spare parts...

Page 2: ......

Page 3: ...allation or on the unit Subject to changes errors and typographical errors excepted Unit description 4 Installation 5 Safety information 6 Commissioning 6 Decommissioning 9 Unit transport 9 Care and m...

Page 4: ...ed The units return to the previously selected mode In an unsupervised continuous mode with external condensate connection the produced condensate is continuously drained via a hose connection on the...

Page 5: ...on is achieved when the units are installed about 1 m above the ground The room to be dried or dehu midified must always be closed from the ambient atmosphere Open windows doors etc as well as frequen...

Page 6: ...the switch off timer for 2 4 or 8 hours AUTO SWING This button is used to activate the automatic swing mode of the air directing flap IONIC This button is used to switch on the ioniser for enriching...

Page 7: ...ted mode MODE IONIC and AUTO SWING is active when the unit is switched on NORMAL This is the comfort mode The unit regulates according to time 12 hours or on reaching the preset humidity the dehu midi...

Page 8: ...g etc IONISER The unit has an ioniser genera tor for the generation of negative ions A high concentration of negative ions occurs e g in mountainous regions at waterfalls and in forests and the air we...

Page 9: ...tion to subsequently dripping condensate Prior to possible storage the units must be cleaned thoroughly and dried For storage purposes the units should be covered with plastic sheeting and stored in a...

Page 10: ...the plug from the power socket 3 Pull the air inlet grille out of the unit at the recessed grip G ATTENTION The units must not be used without air inlet grille fitted G All moving parts are provided...

Page 11: ...The FULL TANK indicator light must not light up Check the microswitch of the condensate container Check for free air flow Overheating Check the miniature fuse on the control pcb The unit operates but...

Page 12: ...operated by suitably trained persons who are familiar with the operation of the unit The manufacturer is not liable for any damage attributed to failure to observe the manufacturer s instructions or...

Page 13: ...13 Date Signature 14 Date Signature 15 Date Signature 16 Date Signature 17 Date Signature 18 Date Signature 19 Date Signature 20 Date Signature Remarks Type of unit Serial number 1 2 3 4 5 6 7 8 9 10...

Page 14: ...nt Heating element Thermal fuse Rear Heating element Heating element Transformer Output Transformer Input Control panel Thermostat Heating element Fan Circulation air Fan Regeneration circuit Adsorpti...

Page 15: ...output l day 8 7 at 20 C 70 relative humidity l day 8 0 at 15 C 60 relative humidity l day 7 0 Max air volume flow m3 h 150 Condensate container capacity Litre 3 0 Power supply V 230 1 Frequency Hz 50...