NEVER LEAVE HEATER UNATTENDED
WHILE BURNING OR WHILE CONNECTED
TO A FUEL SOURCE
© 2018 Pinnacle Climate Technologies, Inc.
Propane Tank Top Heater User’s Manual
12
OPERATION (CONT.)
Lighting Instructions (cont.)
9. Once lit, keep the plunger depressed for
thirty (30) seconds. Then release the plunger,
and if the burner stays lit, remove and
extinguish the match. You will know that the
burner is lit when the mesh screen begins to
glow red.
10. If the burner does not stay lit, repeat the
lighting process. If the heater does not
light after several attempts, be sure you are
getting fuel to the burner. The faint smell
of gas will tell you if the fuel is flowing. If
not, there may be a problem with your LP
cylinder. Take it back to your local dealer for
replacement.
11. Once the burner is lit, turn Regulator Control
Knob to desired setting (HI) / (MED) / (LO ).
12. Light all burners when maximum heat is
desired. Follow Lighting Instructions steps
1-11. The second and third burner should
be lit separately. Do Not Attempt to light
second burner off the first burner. Be sure
NOT to point burners at one another.
To Turn Off Heater:
1. Turn the valve on the LP cylinder CLOCKWISE
to stop the flow of fuel.
2. Turn the heater regulator knob to the (OFF)
position and wait at least fifteen (15) minutes
for the heater to cool.
3. Tightly close the gas shutoff valve on the LP
cylinder after each use.
4. Remove the heater from the LP cylinder by
reversing the steps in
Connecting Heater to
LP Cylinder
on Page 9.
DO NOT store the LP
cylinder with the heater still attached or in an
enclosed area.
NOTE: ALWAYS INSPECT HEATER BEFORE USE
AND AT LEAST ANNUALLY BY A QUALIFIED
SERVICE PERSON.
EXTREMELY HOT during
operation. Do Not touch any
metal components while in operation. Keep
gasoline and any other flammable liquids
away from the heater.
DANGER
Never bring or store a
propane cylinder indoors.
DANGER
DO NOT insert the lit match
into the air inlet holes in the
mixing tube.
CAUTION
MAINTENANCE AND STORAGE
1. Inspect your heater before each use. Check
all connections for leaks, following the
procedure outlined on Page 9. Check the
Regulator Hose (dual burner models only)
for any cracks, breaks or wear. If the hose
is damaged replace it with the correct
manufacturers part. Heater should be
inspected before each use and once annually
by a qualified service person.
2. After use, always disconnect the heater
from the LP cylinder, and store the heater
separately from the tank. Be sure to close
the tank valve after use, and before storage.
The LP cylinder should be stored outdoors in
accordance with chapter 5 of the Standard
for Storage and Handling of Liquefied
Petroleum Gases (ANSI/INFPA 58).