background image

MODEL NUMBERS

REM-16-TTC-O / REM-32-TTC-O / REM-47-TTC-O

User’s Manual & 

Operating Instructions

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS 

HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE 

FROM HAZARDS OF FIRE, EXPLOSION, BURN. ASPHYXIATION, AND/OR CARBON MONOXIDE 

POISONING.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE 

OR SERVICE THIS HEATER. IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS 

AN INSTRUCTIONS MANUAL, LABEL, ETC. CONTACT THE MANUFACTURER.

DANGER

CONSUMER: READ AND SAVE THESE INSTRUCTIONS

FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: 

The temporary heating of adequately ventilated buildings or 

structures under construction, alteration or repair.

FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUS-

TIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DIS-

TANCE AWAY FROM THE HEATER AS RECOMMENDED BY THESE INSTRUCTIONS. NEVER USE 

THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTI-

BLES, OR PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES OR 

UNKNOWN CHEMICALS.

WARNING

Factory ID: 522

1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989

Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: [email protected]

© 2018 Pinnacle Climate Technologies, Inc. R

G

T

B-

40

2

PROPANE TANK TOP 

HEATER

Locating Your Serial Number:

Your serial number can be found in the bottom left hand corner of the heater’s instruction hang-

tag. It will begin with the letters “PGTT” followed by 8 digits. For Example: PGTT12345678. 

Have your Serial Number ready before calling customer service at 866-676-1989.

Summary of Contents for REM-16-TTC-O

Page 1: ...struction alteration or repair FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUS TIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DIS TANCE AWAY FROM THE HEATER AS RECOMMENDED BY...

Page 2: ...ion heater in accordance with Standard ANSI Z83 7 2011 CSA 2 14 2011 CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE ANY QUESTIONS ABOUT APPLICATIONS Other standards govern the use of fuel gas...

Page 3: ...T TED ONLY FOR The temporary heating of adequately ventilated buildings or structures under construction alteration or repair Pro vide at least a three square foot 2 800 sq cm opening of outside air f...

Page 4: ...tion Code CSA B149 1 Gas supply connections should be checked by using a 50 50 soap and water solution Never use a flame to check for gas leaks Do not direct heater discharge towards the LP cylinder u...

Page 5: ...M 47 TTC O BTU 12 14 16 000 25 28 32 000 36 40 47 000 Fuel Consumption Lbs hr 0 56 0 65 0 74 1 16 1 30 1 49 1 67 1 86 2 18 Maximum Operating Hours 35 9 30 8 27 0 17 2 15 4 13 4 12 0 10 8 9 2 Required...

Page 6: ...Inc Propane Tank Top Heater User s Manual 6 FEATURES CONT REM 32 TTC O Regulator Front Guard Heat Reflector Rear Guard Ignition Hole Tip Over Switch Safety Valve REM 47 TTC O Mounting Bolt Knob Hose...

Page 7: ...A FUEL SOURCE 2018 Pinnacle Climate Technologies Inc Propane Tank Top Heater User s Manual 7 WHAT S IN THE BOX REM 16 TTC O REM 32 TTC O REM 47 TTC O 1 Mount and Unit with Single Burner Head 1 Unit wi...

Page 8: ...k collar bracket to the center plate Model REM 47 TTC O Tools Needed Medium Phillips head screwdriver 1 Insert the mounting bolt knob into the tank collar bracket 2 Place tank collar bracket on the sw...

Page 9: ...or to using the heater Model REM 16 TTC O 1 Be sure that the control knob on the regulator is in the OFF position 2 Line up the threads on the fuel connector nut with the threads on the LP cylinder va...

Page 10: ...lowing A collar to protect the gas valve A shut off valve terminating a LP cylinder valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve Outlets and Inlets Con...

Page 11: ...r including near the floor If you do smell gas STOP Follow the safety instructions and check leaks If there is no gas smell proceed to the next step 5 Turn the regulator knob COUNTERCLOCKWISE to the H...

Page 12: ...ion and wait at least fifteen 15 minutes for the heater to cool 3 Tightly close the gas shutoff valve on the LP cylinder after each use 4 Remove the heater from the LP cylinder by reversing the steps...

Page 13: ...to HI position 4 Replace regulator assembly Burner will not stay lit when gas valve plunger is released 1 Tip switch activated or defective 2 Wire terminal connections unplugged 3 Defective thermocou...

Page 14: ...Propane Tank Top Heater User s Manual 14 EXPLODED VIEW 4 1 3 2 PARTS LIST Item Description REM 16 TTC O REM 32 TTC O REM 47 TTC O 1 Hose Assembly 20 051 0001 20 051 0002 2 Thermocouple 20 091 0002 20...

Page 15: ...e Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnac...

Page 16: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 17: ...n modificaci n o reparaci n PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N MANTENGA LOS COMBUSTIBLES S LIDOS COMO MATERIALES DE CONSTRUCCI N PAPEL O CART N A UNA DISTANCIA PRUDENTE DEL CALENTA...

Page 18: ...calentador est dise ado y aprobado para uso en construcciones de acuerdo con la norma ANSI Z83 7 2011 CSA 2 14 2011 CONSULTE CON LAS AUTORIDADES DE SEGURIDAD DE INCENDIOS DE SU LOCALIDAD SI TIENE ALG...

Page 19: ...Calefacci n temporal de edificios adecuadamente ventilados o estructuras en construcci n modificaci n o reparaci n Proporcione una abertura de al menos tres pies cuadrados 0 28 metros cuadrados al air...

Page 20: ...A 58 y el C digo de instalaci n de gas natural y gas propano CSA B149 1 Las conexiones de suministro de gas deben revisarse usando una soluci n de 50 50 de agua y jab n Nunca use una llama para verifi...

Page 21: ...kWh 12 14 16 000 1 9 3 5 5 3 25 28 32 000 36 40 47 000 Consumo de combustible Lb h 0 56 0 65 0 74 1 16 1 30 1 49 1 67 1 86 2 18 Horas m ximas de funcionamiento 35 9 30 8 27 0 17 2 15 4 13 4 12 0 10 8...

Page 22: ...ropano 6 CARACTER STICAS CONT REM 32 TTC O Regulador Protecci n delantera Reflector de calor Protecci n trasera Orificio de encendido Interruptor antivuelco V lvula de seguridad REM 47 TTC O Perilla d...

Page 23: ...BLE 2018 Pinnacle Climate Technologies Inc Manual del usuario del calentador para tanque de propano 7 QU HAY EN LA CAJA REM 16 TTC O REM 32 TTC O REM 47 TTC O 1 Soporte y unidad con un solo cabezal de...

Page 24: ...M 47 TTC O Herramientas necesarias Destornillador Phillips mediano 1 Inserte la perilla del perno del montaje en la pieza de montaje del collar n del tanque 2 Coloque la pieza de montaje del collar n...

Page 25: ...lentador Modelo REM 16 TTC O 1 Aseg rese de que la perilla de control del regulador est en la posici n OFF apagado 2 Alinee las roscas de la tuerca del conector de combustible con las roscas de la v l...

Page 26: ...siguiente Un anillo para proteger la v lvula de gas Una v lvula de corte conectada en la salida de la v lvula del tanque de LP seg n la especificaci n de la Norma Nacional Americana para la conexi n d...

Page 27: ...luso cerca del piso Si huele a gas DET NGASE Siga las instrucciones de seguridad y verifique si hay fugas Si no huele a gas contin e al siguiente paso 5 Gire la perilla del regulador HACIA LA IZQUIERD...

Page 28: ...e apagado y espere a que se enfr e el calentador al menos quince 15 minutos 3 Cierre firmemente la v lvula de corte de gas en el tanque de LP despu s de cada uso 4 Separe el calentador del tanque de L...

Page 29: ...ce encendido al soltar el mbolo de la v lvula de gas 1 El interruptor de seguridad est activado o defectuoso 2 Las conexiones de terminal de cables no est n conectadas 3 El termopar est defectuoso 4 L...

Page 30: ...usuario del calentador para tanque de propano 14 VISTA DETALLADA 4 1 3 2 LISTA DE PIEZAS Pieza Descripci n REM 16 TTC O REM 32 TTC O REM 47 TTC O 1 Conjunto de la manguera 20 051 0001 20 051 0002 2 T...

Page 31: ...ubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada reemplaza a todas las dem s garant as...

Page 32: ...dustrial Blvd 101 Sauk Rapids MN 56379 EE UU Llamada sin costo 866 676 1989 Fax 320 251 2922 Web www remingtonheater com Correo electr nico info pinnacleclimate com 2018 Pinnacle Climate Technologies...

Reviews: