background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

© 2018 Pinnacle Climate Technologies, Inc. 

Kerosene Forced Air Heater User’s Manual 

3

SAFETY INFORMATION (CONT.)

ALWAYS use only the electrical power (voltage and 

frequency) specified on the model plate of the heater.

ALWAYS use only three-prong, grounded outlet and 

extension cord. 
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.  
ALWAYS install the heater so that it is not directly 

exposed to water spray, rain, dripping water, or 

wind.

NEVER use fuels such as gasoline, benzine, paint 

thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater is 

operating or still hot. This heater is EXTREMELY HOT 

while in operation. 
NEVER block air inlet (rear) or air outlet (front).

NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.

Keep all combustible materials away from this heater. 

Minimum Clearance From Combustibles

45-190T-KFA

215T-KFA

Top

4 ft. (125 cm)

4 ft. (125 cm)

Sides

4 ft. (125 cm)

4 ft. (125 cm)

Front

8 ft. (250 cm)

10 ft. (305 cm)

ALWAYS locate heater on a stable and level surface. 
If your heater is equipped with a thermostat, once 

it is plugged in, it can start at anytime in accordance 

with the thermostat setting. 

RISK OF BURNS, 

FIRE AND 

EXPLOSION!

RISK OF ELECTRIC 

SHOCK!

WARNING

WARNING

CAUTION! HOT 

WHILE IN OPERA-

TION. DO NOT 

TOUCH. KEEP CHILDREN, ANIMALS, 

CLOTHING AND COMBUSTIBLES AWAY 

FROM HEATER. 

WARNING

The products described in this manual are 

kerosene direct-fired, forced air heaters. 

Kerosene forced air heaters are primarily 

intended for use for temporary heating of 

buildings under construction, alteration or repair. 

Direct-fired means that all of the combustion 

products of the heater enter the heated space. 

This appliance is rated at 98% combustion 

efficiency, but does produce small amounts of 

carbon monoxide.

Carbon monoxide is toxic. Humans can tolerate 

only small amounts of carbon monoxide and so 

precautions should be taken to provide proper 

ventilation. Failure to provide proper ventilation in 

accordance with the instructions in this manual can 

result in death. People with breathing problems 

should consult a physician before using this 

heater. Early signs of carbon monoxide poisoning 

resemble the flu. Symptoms of improper 

ventilation/carbon monoxide poisoning are:

Headache • Dizziness • Nausea 

• 

Dry Mouth 

Sore Throat 

 Burning of Nose and Eyes

If you experience any of these symptoms: 

GET FRESH AIR AT ONCE! 

Have your heater 

serviced and check for proper ventilation. Some 

people are more affected by carbon monoxide than 

others. These include: pregnant women, those with 

heart or lung problems, anemia or those under the 

influence of alcohol or at high altitudes. 

FOR OUTDOOR USE. INDOOR USE 

PERMITTED ONLY FOR: The temporary 

heating of adequately ventilated buildings 

or structures under construction, alteration 

or repair. Provide at least a three square 

foot (2,800 sq cm) opening of outside air for 

every 100,000 Btu/Hr (29 kW) heater rating. 

Refer to “Ventilation” on page 6 for further 

instructions.

RISK OF INDOOR 

AIR POLLUTION!

WARNING

CARBON 

MONOXIDE 

POISONING MAY 

LEAD TO DEATH!

DANGER

Summary of Contents for REM-140T-KFA-O

Page 1: ...OUT ADEQUATE VENTILATION FOR OUTDOOR USE INDOOR USE PERMITTED ONLY FOR THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTERATION OR REPAIR This is an unvente...

Page 2: ...ART THE HEATER WHEN THE CHAMBER IS HOT WARNING WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the h...

Page 3: ...D COMBUSTIBLES AWAY FROM HEATER WARNING The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heat...

Page 4: ...ackaging materials from the shipping carton Note Save the box and packaging materials for future storage Shown With Optional Cord Wraps Cord Wraps Optional Carry Handle 1 10 mm Screws 2 WHAT S IN THE...

Page 5: ...into the button spring clips at the rear of the top support frame 8 Check all parts to ensure they are secure before operating the heater SPECIFICATIONS Model 45 KFA 80T KFA 140T KFA 190T KFA 215T KFA...

Page 6: ...ht or near a source of heat NEVER use kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should...

Page 7: ...o not have a room temperature display feature The room temperature display will indicate the following When the temperature is less than 0 F the display says LO When the temperature is more that 99 F...

Page 8: ...re starting the heater FUEL FILTER The fuel filter should be cleaned at least twice per heating season Clean the filter by rinsing it in clean K 1 Kerosene Contaminated fuel could make cleaning the fu...

Page 9: ...E While heater is operating turn adjusting screw clockwise to increase counter clockwise to decrease pressure Correct pump pressure is as follows Model Number Pump Pressure 45 KFA 3 0 PSI 0 21 BAR 80T...

Page 10: ...A POWER SOURCE 2018 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 10 WIRING DIAGRAMS 80T KFA 140T KFA 175T KFA 190T KFA 215T KFA Models 140T 175T 190T 215T KFA have a digi...

Page 11: ...mproper spacing with rotor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace nozzle 6 Rinse fuel tank with clean fresh keros...

Page 12: ...WER SOURCE 2018 Pinnacle Climate Technologies Inc Kerosene Forced Air Heater User s Manual 12 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17 18 20 30 19 14 40 32 34 35 28 27 5 31 30 24 26 37 36 38 3...

Page 13: ...2 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 End Pump Cover 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 20 Filter Kit 70 054 0100 70 054 0100 70 054 0100 70 054 0100 70 05...

Page 14: ...aid If Pinnacle Climate Technologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other exp...

Page 15: ...ECUADA PARA USO EN EXTERIORES EL USO EN INTERIORES S LO SE PERMITE PARA CALEFACCI N TEMPORAL DE EDIFICIOS ADECUADAMENTE VENTILADOS O ESTRUCTURAS EN CONSTRUCCI N MODIFICACI N O REPARACI N Este es un ca...

Page 16: ...ww P65Warnings ca gov NO ENCIENDA EL CALENTADOR CUANDO LA C MARA EST CALIENTE PELIGRO DE INCENDIO QUEMADURAS INHALACI N Y EXPLOSI N Mantenga los combustibles como materiales de construcci n papel o ca...

Page 17: ...Los productos descritos en este manual son calentadores de aire forzado de fuego directo de queroseno Los calentadores de aire forzado de queroseno est n hechos expresamente para calefacci n temporal...

Page 18: ...de la caja de env o Nota Guarde la caja y los materiales de empaque para cuando guarde la unidad posteriormente Ilustrado con enrolladores de cable opcionales Enrolladores de cable Opcional Asa 1 Tor...

Page 19: ...para asegurar que est n bien firmes antes de hacer funcionar el calentador ESPECIFICACIONES N de modelo 45 KFA 80T KFA 140T KFA 190T KFA 215T KFA Capacidad nominal Btu H 45 000 80 000 140 000 190 000...

Page 20: ...o que haya estado almacenado de una temporada a la siguiente El queroseno se deteriora con el tiempo EL QUEROSENO VIEJO NO SE QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El queroseno debe almacenarse...

Page 21: ...iguiente Cuando la temperatura es inferior a 0 F 18 C la pantalla mostrar LO Baja Cuando la temperatura es superior a 99 F 37 C la pantalla mostrar HI Alta Entre 0 F 18 C y 99 F 37 C la pantalla mostr...

Page 22: ...dor FILTRO DE COMBUSTIBLE El filtro de combustible debe limpiarse al menos dos veces por cada temporada de calefacci n Enjuague el filtro con queroseno K 1 limpio El combustible contaminado podr a hac...

Page 23: ...calentador est funcionando gire la v lvula de seguridad hacia la derecha para aumentar la presi n o hacia la izquierda para disminuirla A continuaci n se muestra la presi n correcta de la bomba Modelo...

Page 24: ...NEGRO NEGRO VERDE ENCHUFE DE ALIMENTACI N INTERRUPTOR DE ENCENDIDO CONTROL DE L MITE FUSIBLE 8A 125AVC LUZ LED PCI DE CONTROL LUZ LED TERMOSTATO CONTROL DE TEMP FOTOC LULA SENSOR DE AMBIENTE NEGRO NE...

Page 25: ...resi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con queroseno nuevo y limpio 7 Inspecc...

Page 26: ...E DE ALIMENTACI N 2018 Pinnacle Climate Technologies Inc Manual del usuario del calentador de aire forzado de queroseno 13 10 12 8 11 9 29 25 3 15 2 4 6 1 7 21 23 16 17 18 20 30 19 14 40 32 34 35 28 2...

Page 27: ...0 020 0401 70 020 0401 18 Juego de rotor 70 022 0100 70 022 0100 70 022 0100 70 022 0200 70 022 0200 19 Cubierta de la bomba 70 020 0102 70 020 0102 70 020 0102 70 020 0102 70 020 0102 20 Conjunto de...

Page 28: ...Technologies Inc descubre que el art culo est en condiciones normales de funcionamiento o que no est defectuoso se devolver el art culo con el flete por cobrar Esta Garant a Limitada reemplaza a toda...

Reviews: