background image

5

• 

DO NOT

 use on dark brown or black spots such as moles, birth marks or 

freckles.

• 

DO NOT

 use on an area of recent surgery, deep peel, laser resurfacing, scars 

or skin that has been damaged with burns or scalds.

WHEN NOT TO USE/WHEN TO AVOID USING I-LIGHT®

• 

DO NOT

 use if you have tanned skin in the intended treatment area, as your 

skin may be too dark and treatment in tanned areas could temporarily cause 

skin swelling, blisters, or could change the colour of your skin. Wait until 

your tan has faded before treating.

• 

DO NOT

 use on skin with cosmetics applied, as treating in those areas could 

temporarily cause skin swelling, blisters or could change the colour of your 

skin. Make sure to thoroughly clean the intended treatment area prior to 

use.

• 

DO NOT

 flash the same treatment spot multiple times during the same 

session, as this could temporarily cause skin swelling, blisters, or could 

change the colour of your skin.

• 

DO NOT

 treat any area more than once every two weeks, as this will not 

speed up results, but could increase likelihood of skin swelling, blistering or 

changes to the colour of your skin.

• 

DO NOT

 use on damaged skin, including open wounds, cold sores, sunburn 

or areas where you have had a skin peel or other skin resurfacing procedure 

within the last 6-8 weeks.

• 

DO NOT

 use on irritated skin, including rashes or swollen skin. These 

conditions can make the skin more sensitive. Wait for the affected area to 

heal before use.

• 

DO NOT

 use if your skin is sensitive to light. In order to determine if you can 

use i-LIGHT®, perform a test on a small patch of skin and wait 24 hours to 

determine if there are any adverse reactions before treating more broadly.

• 

DO NOT

 use if you are or may be pregnant or are breast-feeding. i-LIGHT® 

has not been tested on pregnant women. Hormonal changes are common 

during pregnancy and breastfeeding and could increase skin sensitivity and 

the risk of skin injury.

• 

DO NOT

 flash against any material other than skin.

• 

DO NOT

 use i-LIGHT® for any purpose other than hair removal.

• 

DO NOT

 treat any area where you may someday want your hair to grow 

back. The results may be permanent and irreversible.

Summary of Contents for i-LIGHT Compact Control

Page 1: ...1 2 YEAR WARRANTY IPL3500AU...

Page 2: ...black skin white grey or very light blonde red hair FOR FACIAL USE Only suitable for female facial use below the cheekbone DO NOT use on or around the eyes eyebrows or eyelashes Doing so can cause se...

Page 3: ...d chest IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF BURNS ELECTROCUTION FIRE OR INJURY TO PERSONS 1 Use this appliance only for its intended use described in this manual 2 Do not use i...

Page 4: ...gin check to see if i LIGHT is suitable for you Use the skin and hair chart at the front of this manual page 2 and the integrated skin sensor to determine if this device is right for you For Facial Us...

Page 5: ...weeks as this will not speed up results but could increase likelihood of skin swelling blistering or changes to the colour of your skin DO NOT use on damaged skin including open wounds cold sores sunb...

Page 6: ...ur skin to disable your hair at the root so it is not effective if the hair has been pulled out DO NOT use directly over or near Active Implantable Medical Devices such as implantable pacemakers inter...

Page 7: ...7 i LIGHT COMPACT CONTROL KEY FEATURES PARTS 1 Adapter Socket 2 Energy Level Indicator Lights 5 3 Control Button 4 Ready Light 5 Treatment Window 6 Skin Tone Tester 7 Adapter not shown...

Page 8: ...take 18 24 months During this time multiple treatment sessions are required to achieve permanent hair reduction A typical hair reduction plan during a full hair growth cycle includes Treatments 1 6 Pl...

Page 9: ...ned on the energy level is set to level 1 automatically Only one energy level indicator light will be on To change the energy level press the control button repeatedly to increase the energy level fro...

Page 10: ...igmentation The built in skin tone tester detects the colour of your skin automatically The skin tone tester checks your skin colour at the start of and occasionally during each treatment If your skin...

Page 11: ...ng at increased energy levels If you do not experience any adverse effects within 24 hours you can start the full treatment at that energy level Use a lower energy level if you experience any discomfo...

Page 12: ...the control button an extended press Remember the last energy level setting you used because it will not be restored when you turn the device on again 2 Remove the adapter from the electrical outlet C...

Page 13: ...e the adapter is properly connected to the device and that it is plugged into an electrical outlet on the wall There is no light pulse when the device touches my skin Check that the device is connecte...

Page 14: ...like the hair is still growing but it is actually being pushed out Hair grows in a cycle of 3 different phases which lasts 18 24 months Only hairs in the active growth phase are susceptible to treatme...

Page 15: ...ring within the guarantee period will be corrected by replacement or repair at our discretion provided the product is used and maintained in accordance with the instructions Defects from repair by an...

Page 16: ...ilure does not amount to a major failure 2 The benefits provided by this Warranty are in addition to all other rights and remedies in respect of the Goods which the consumer has under either the Austr...

Page 17: ...Supplier the date and place of purchase the product name or other product serial number and ii this warranty 9 This warranty is immediately void if a Any serial number or appliance plate is removed o...

Page 18: ...18...

Page 19: ...19...

Page 20: ...ck Offer Australia New Zealand Only If within 90 days you are not fully satisfied with your Remington i LIGHT Compact Control please call your local Remington Customer Service Centre Australia 1800 62...

Reviews: