Modbus Register Map

Register 

Name

Comment

Register Type R/W Default 

Value

Range

Modbus 

Address

Machine ID Machine ID

Unsigned short

R

7

40001

FW version Firmware version

Unsigned short

R

0

40002

Address

Modbus address

Unsigned short R/W

1

40003

Delay

Machine answer delay (in characters) Unsigned short R/W

1

0..1000

40004

Baudrate

0= 1200, 1= 2400, 2= 4800, 3= 

9600, 4= 19200, 5= 38400, 6= 

57600,  7= 115200

Unsigned short R/W

1

0..7

40005

Parity

0= NO, 1= ODD, 2= EVEN

Unsigned short R/W

0

0..2

40006

DC Filter

Number of tenths of second (1/10) for 

all RMS calculation in DC

Unsigned short R/W

10

1..65535

40007

Flag 

Measurement

bit 0 :[ 0= TRMS value (without sign); 

1 = DC_measurement (with sign)];

bit 1:[ 0= Energy stori ng disable; 

1= Energy storing enable]; 

bit 2 :[ 0= Frequency detect on 

Voltage channel; 1= Frequency 

detect on Current channel].

Unsigned short R/W

0x10

40008

TV_Ratio

Voltage transformer ratio

Float

(LSW first)

R/W

1.0

40009

40010

TA_Ratio

Current transformer ratio

Float

(LSW first)

R/W

1.0

40011

40012

# of ZX for VI 

measurement

Number of ZX for_AC Meas Number 

of line cycle Zero Crossings for AC 

measurement RMS.

Unsigned short R/W

50

1..65535

40014

STATUS

bit 0: flash settings error; 

bit1: flash calibration error; 

bit 2: Voltage Over Range; 

bit 3: Voltage Under Range; 

bit [4:5] Reserved; 

bit 6: Zero crossing detecting; 

bit [7:9] Reserved; 

bit 10: Energy storing error; 

bit 11: Energy initialization error; 

bit 12: Reserved; 

bit 13: Current Over Range; 

bit 14: Current Under Range;

bit 15: Reserved.

Unsigned short

R

0

40072

V RMS

Voltage RMS Measurement (V)

Float

(LSW first)

R

40073

40074

I RMS

Current RMS Measurement (mA)

Float

(LSW first)

R

40075

40076

Summary of Contents for ENERGY-0-RS

Page 1: ...ENERGY 0 RS Energy Meter User manual TRMS AC DC i RMS 800Vac 1000Vdc Watt Var Vpk Frecuency Energy bidireccional COS phi V rms 50A ac dc RS485...

Page 2: ...del identification 4 3 Technical data 4 3 1 Main features 4 3 2 Hardware and software features 4 4 Dimensions and Installation 6 5 Electrical wirings 6 6 Mounting 7 7 Configuration 7 7 1 Remarks 7 8 E...

Page 3: ...manual Do not dispose electric tools together with household waste material In observance European Directive 2002 96 EC on waste electrical and electronic equipment and its implementation in accordan...

Page 4: ...Samples per Second Input impedence 1 M ohm 1 Isolation 3 kV on bare wire for Current measure 4 kV for Voltage measure reinforced insulation to power supply and serial output Hysteresis 0 15 f s Humid...

Page 5: ...d to resist electromagnetic interferences in industrial environments please observe following safety guidelines Separate the control line from the power wires Avoid proximity of remote control switche...

Page 6: ...as per Modbus RTU standards Modbus Register reference with reference to the logical address for ex 40010 corresponds to physical address n 9 as per Modbus RTU standard Modbus functions supported 3 Re...

Page 7: ...fine the transformation ratio for the current input and voltage input the default ratio is 1 1 Filter Allows to insert a filter on reading in order to get more speed in responding value 1 or a more st...

Page 8: ...gystoringdisable 1 Energystoringenable bit2 0 Frequencydetecton Voltagechannel 1 Frequency detectonCurrentchannel Unsignedshort R W 0x10 40008 TV_Ratio Voltagetransformerratio Float LSWfirst R W 1 0 4...

Page 9: ...40091 40092 Energy negative OnlynegativeEnergyMeasurement KWh Float LSWfirst R 40093 40094 Vpeak InstantaneousVoltagePeak V Float LSWfirst R W 40095 40096 Ipeak InstantaneousCurrentPeak mA Float LSWf...

Page 10: ...bit6 Zerocrossingdetecting bit 7 9 Reserved bit10 Energystoringerror bit11 Energyinitializationerror bit12 Reserved bit13 CurrentOverRange bit14 CurrentUnderRange bit15 Reserved Unsignedshort R 40132...

Page 11: ...ed Float MSWfirst R W 40163 40164 IminSW MinRMSCurrent mA swapped Float MSWfirst R W 40165 40166 PMAXSW MaxRMSPower W swapped Float MSWfirst R W 40167 40168 PminSW MinRMSPower W swapped Float MSWfirst...

Page 12: ...100 ApparentPowermeasurement VA 100 inhundredths Signedlong LSWfirst R 40201 40202 Cos 100 Cos measurementinhundredths Signedlong LSWfirst R 40203 40204 Frequency100 Frequencymeasurement Hz 100 in hun...

Page 13: ...edths Signedlong LSWfirst R W 40237 40238 Cos MAX100 MaxCos inhundredths Signedlong LSWfirst R W 40239 40240 Cos min100 MinCos inhundredths Signedlong LSWfirst R W 40241 40242 FrequencyMAX 100 MaxFreq...

Page 14: ...Read carefully the safety guidelines and programming instructions contained in this manual before using connecting the device 2300 10 219 RevA Software Rev 1 00 080914...

Reviews: