Rema Tip Top EXPEL 30 Faq Download Page 6

6

OPERATION

DOES EXPEL COST ANYTHING TO OPERATE?

Th e simple answer is NO. Th ere are no power requirements, and no consumable related costs associated with 
the EXPEL unit so the only cost involved is for the initial unit purchase.

HOW DOES EXPEL WORK?

Th e internal Expel fi lter works by creating an impacting turbulent air path thus coalescing any liquids and 
solids present in the compressed air line during the fi rst stage of fi ltration. As part of this initial phase Expel 
removes 96% of all contamination while during the second stage the internal Unitary Vertical Body (UVB) 
polishes the compressed air still further thus removing the fi nal 4% before exiting the fi lter air outlet. 

Th e fi lter is manufactured from a strong polymer material, so it never needs replacing – ever. However, if you 
have particularly dirty air lines then we would recommend that you simply dismantle and clean the internal 
elements of the unit when necessary. Th e internal element does not need replacing. 

WHAT IS THE INDICATOR FOR ON THE TOP OF THE EXPEL UNIT?

Th e indicator on the top of the unit is to provide a visual warning that the unit is under pressure. Once the 
system is pressurized, the indicator will turn RED. Th e locking mechanism within the unit will prevent the unit 
being opened when under pressure.

DRAINING

HOW DO I DRAIN THE EXPEL UNIT?

Th e EXPEL 30 unit comes equipped with an Automatic Float Drain. Th is fl oat drain is designed to discharge 
liquids and particulates extracted from your compressed air system. Th e Auto Float Drain is screwed directly 
to the base of the EXPEL unit and has an operation pressure up to 232 psi. A 6 mm diameter plastic tube can 
be connected to the base of the drain to control the fl ow of the discharge fl uid into a suitable container for 
disposal. Th e Automatic Float Drain can be easily dismantled for servicing and cleaning if required.

EXPEL 30 FILTER & AUTO DRAIN SET

FREQUENTLY ASKED QUESTIONS

Summary of Contents for EXPEL 30

Page 1: ...EXPEL 30 FILTER AUTO DRAIN SET FREQUENTLY ASKED QUESTIONS FREQUENTLY ASKED QUESTIONS...

Page 2: ...WATER SEPARATORS ON THE MARKET Conventional lters tend to remove water using the cyclonic method rather than the patented multi directional vanes and clari cation chambers inside the EXPEL These vanes...

Page 3: ...d ISO test which is component speci c EXPEL complies with ISO12500 1 2009 Oil Aerosols ISO12500 3 2009 Particulates ISO12500 4 2009 Water DOES EXPEL REMOVE SOLID PARTICULATES AS WELL AS LIQUID WATER A...

Page 4: ...e the temperature of the compressed air and this rapid reduction causes water vapor water in a gas state to condense into liquid water To stop this high volume of water travelling through your compres...

Page 5: ...is designed to t either or pipework The unit is supplied as standard with a BSPT thread in the head and within the box there are ush tting adaptors to reduce the BSPT thread to BSPT thread ttings MY...

Page 6: ...dismantle and clean the internal elements of the unit when necessary The internal element does not need replacing WHAT IS THE INDICATOR FOR ON THE TOP OF THE EXPEL UNIT The indicator on the top of th...

Page 7: ...ing away from the compressor and towards the end of the air line 2 Is there a blockage within the unit The unit will need to be disassembled and inspected for a blockage I HAVE INSTALLED MY EXPEL UNIT...

Page 8: ...MACLEAN T Bar Scrapers REMACLEAN Green Combi REMACLEAN Grey Combi REMACLEAN Cleaning Brush Pulley Lagging PERFORMANCE GRIP 70 REMAGRIP REMAGRIP Ceramic Lagging UNIGRIP UNILAG T REX Skirting REMASKIRT...

Reviews: