RMV800 SERVICE MANUAL
-
67
-
Dealer Mode 9: Emergency Set
Select menu “Emergency Set”, then press [PF6] to enter.
No.
Function
Setting
Display
Remarks
ZONE: 1-256
1
Emergency Zone
Emergency CH
CH: 1-512
1
CH 100.
Selector Knob: change a
channel or zone (default ch)
[PF5]: channel/zone
Continuous
Cycle Contin
1-200
Cycle 1
2 Emergency
Cycle
Step 1
Cycle 200
Off
Key
Deley Off
0.1-5.0s
Key
Deley 0.1S
3
Emergency Key
Delay Time
Step 0.1s
Key
Deley 5.0S
20s
Tx
Dur. 20S
Default data
Tx
Dur. 1S
4 Tx
Duration
1-60s
Step 1s
Tx
Dur. 60S
20s
Tx
Dur. 20S
Default data
1-180s
Tx
Dur. 1S
5 Rx
Duration
Step 1s
Tx
Dur. 180S
Off
Type Off
DTMF
Type DTMF
6 Emergency
Type
MSK
Type MSK
-----------------------
ID
-----------------------
No input
ID
0000000000000000
7 Emergency
ID
0000000000000000
9999999999999999
ID
9999999999999999
Off
LED Off
8 Emergency
Led
On
LED On