Congratulations  on  your  purchase  of  the  Reliance  Controls  generator  power  transfer  switch. Reliance  has  been
manufacturing  transfer  switches  and  equipment  in  Racine, Wisconsin  since  1983  and  has  been  producing  high-quality
electrical equipment for nearly 100 years. Reliance is the Loadside® transfer switch used in nearly 90% of the installations
done by professional electricians. Your transfer switch is UL 1008 listed, C-UL listed, and meets all requirements of the 2002
National Electrical Code.

All Reliance Controls transfer switches are made to operate with any generator up to 7500 watts continuous output, having
20 or 30 Amp twist-lock power receptacles.

TOOLS NEEDED FOR INSTALLATION

1. Power Drill
2. Wire Stripper and Cutter (10 to 14 gauge)
3. Insulated Screwdrivers

(#2 Phillips, 1/4" Flat Tip or #2 Square Tip depending on
your load center)

4. Hammer
5. Marking Pencil

6. Tape Measure
7. Seven Wall Anchors with at Least a 3/8” Flange
8. Enough 10-3 with Ground Building Wire to reach from

where you install your Outdoor Power Inlet Box to where
you install your transfer switch

9. Battery Powered Lighting during Installation
10. A Non-Contact Voltage Detector (optional)

PARTS LIST for 31406CRK POWER TRANSFER KIT

30 Amp 6-Circuit Transfer switch
30 Amp Outdoor Power Inlet Box
30 Amp 10-foot long Generator Power Cord

4 red and 6 yellow wire connectors

Installation and Operating Instructions

SAFETY SYMBOLS USED IN THIS MANUAL

Danger indicates an imminently hazardous
situation that, if not avoided, could result in
death or serious injury.

Warning indicates a potentially hazardous
situation that, if not avoided, could result in
death or serious injury.

Caution indicates a potentially hazardous
situation that, if not avoided, may result in
minor or moderate injury.

Reliance Controls Corporation is not

responsible for damage or injury

caused by incorrect installation of this

transfer switch.

The double pole branch circuits
connected to this transfer switch are 

to be considered live unless both switches controlling the

c

ircuit are in the off position.  The position of the circuit

breakers are not be relied upon to disconnect the circuit

.

Improper installation of the transfer
switch could cause damage or

personal injury by electrocution or fire. Installation must be
performed by a qualified electrician, or others
knowledgeable of electrical systems, in compliance with
all applicable electrical codes.

  Do not overload.

DANGER

WARNING

CAUTION

WARNING

WARNING

Member of the National Electrical Manufacturers Association

Transfer switches are required for use with portable generators by Article
702 of the 2002 National Electrical Code

NOTE: The 30 Amp power cord plugs into this type of
generator power outlet:

If your generator only has a 20 Amp power outlet like this:

$QLQWHUFKDQJHDEOH$SOXJLVDYDLODEOHXSRQUHTXHVW

IUHHRIFKDUJH3OHDVHFDOOXVRUHPDLO

VXSSRUW#UHOLDQFHFRQWUROVFRP

Summary of Contents for 31406CRK

Page 1: ...8 Completing the Installation 8 Installing and Wiring the Power Inlet Box 9 Wiring the Power Inlet Box to the Transfer Switch 9 Installing an Optional Power Inlet 10 Finishing Up 10 Operating Instruc...

Page 2: ...connectors Installation and Operating Instructions SAFETY SYMBOLS USED IN THIS MANUAL Danger indicates an imminently hazardous situation that if not avoided could result in death or serious injury War...

Page 3: ...n emergency 2 Finding the essential circuit breakers that control these devices 3 Creating a map of all of the other electrical devices plugged into or wired into these circuits A tear off Home Circui...

Page 4: ...Each transfer switch circuit controlled by a toggle switch has a built in corresponding 15 or 20 Amp push to rest circuit breaker that protects the branch circuit when the toggle switch is in the GEN...

Page 5: ...plan the set up of your transfer switch Use the running watts of your appliances rather than starting watts when dividing them between the two halves of the transfer switch Check your appliances for...

Page 6: ...lt Double Pole Circuit Breaker Toggles C D Together Generator 5 500 Running Watts 6 200 Peak Watts Transfer Switch Model 6 Circuits Side One Appliance Additional Toggle Main Appliance Running Start Up...

Page 7: ...er Figure 3 3 Remove the cover of your load center Keep in mind that the wires on the utility side of the main breaker are still live and if contacted could cause serious injury or death If available...

Page 8: ...eaker and retighten the screw on the breaker 4 Cut the black wire from the transfer switch to a length convenient for attaching it to the wire you removed from the refrigerator circuit breaker in 1 St...

Page 9: ...er of the load center 2 If you have not already done so fill in the chart on the top of the transfer switch to identify your emergency circuits and the toggle switches they correspond to 3 Do not turn...

Page 10: ...X and the black wire into the hole marked Y 8 Replace the cover of the power inlet box and tighten the screw H Wiring the Power Inlet Box to the Transfer Switch All Reliance Controls transfer switches...

Page 11: ...n all of the circuit breakers in your load center 2 Turn on the main breaker 3 Position all switches on the transfer switch to the LINE position 4 IMPORTANT In order to insure that all wiring connecti...

Page 12: ...4 6155 to locate the distributor nearest you Power Cords Connect generator power outlets with outdoor power inlet boxes or accessory power inlets PC20100 PC20200 3 0 PC30100 PC30200 3 0 10 foot cord w...

Page 13: ...mponent s or ii repair or replace the Switch Reliance s obligation is strictly limited to said repair or replacement of the Switch and Reliance shall not be liable for any incidental special or conseq...

Page 14: ...PING CHART This Toggle Switch on My Generator Transfer Switch A B C D E F Controls these essential appliances I will need during a power outage So I need to turn off these other devices which are on t...

Page 15: ......

Page 16: ...Reliance Controls Customer Service 800 439 5745 Website www reliancecontrols com 03 04 21...

Reviews: