7
hoW to ChanGe the dIreCtIon
• Press and hold the down
v
speed selector for 2 seconds. The LED
will change to S.0
• Press the up
^
speed selector 2 times. The LED will change to S.2.
• Press the down
v
speed selector again. The LED will change to the current
rotation set r.P or r.E
• Press the up
^
or down
v
speed selector to change the current setting
and wait 4–5 seconds. The set pattern will be saved automatically.
error Codes
Error 1: Short circuit.
Error 2: 4 Pin connector from the motor to the PC board wires may be loose
or broken.
Error 3: The motor has activated the automatic protection circuit.
Error 4: Data storage error or defective PC board.
Error 5: Not Applicable
Error 6: Indicates that the sensor plate positioning is wrong or the sensor is
defective.
Keystone Sewing Machine Company, Inc.
215/922.6900 www.keysew.com [email protected]