7

hoW to ChanGe the dIreCtIon

•  Press and hold the down 

v

 speed selector for 2 seconds. The LED 

will change to S.0

•  Press the up  

^

 

 speed selector 2 times. The LED will change to S.2.

•  Press the down  

v

  speed selector again. The LED will change to the current 

rotation set r.P or r.E

•  Press the up  

 or down  

 speed selector to change the current setting 

and wait 4–5 seconds. The set pattern will be saved automatically. 

error Codes

Error 1:  Short circuit.

Error 2:  4 Pin connector from the motor to the PC board wires may be loose  

or broken.

Error 3:  The motor has activated the automatic protection circuit.

Error 4:  Data storage error or defective PC board.

Error 5:  Not Applicable

Error 6:  Indicates that the sensor plate positioning is wrong or the sensor is 

defective.