background image

The Reliable Automatic Sprinkler Co., Inc.,

 

103 Fairview Park Drive, Elmsford, New York 10523

Bulletin 006 

Rev
.

 E

Bulletin 006 

Rev.

 E

Model RFC43 (SIN RA0612)
Model RFC49 (SIN RA0616)
Residential Flat Concealed
Sprinklers

A Residential Flat Concealed 
Sprinkler engineered for a minimum 
design density of 0.05 gpm/ft

2

 with 

low GPM requirements.

Features

Very low water flow requirements.
½” (13mm) Total adjustment.
Thread-On/Thread-Off or Push-On/Thread 
Off cover attachment option.
Smooth aesthetic ceiling profile.
Available in brass, chrome and black plated 
or painted finishes.

Listings & Approval

Listed by Underwriters Laboratories, and 
certified by UL for Canada (cULus)
NYC MEA 258-93-E

UL Listing Categories

Residential Automatic Sprinklers

UL Guide Number

VKKW

Product Description

Model RFC43 and RFC49 Concealed Residential Sprin-

klers are fast response residential fusible solder link au-
tomatic sprinklers. Residential sprinklers differ from stan-
dard sprinklers primarily in their response time and water 
distribution patterns. 

Model RFC43 and RFC49  sprinklers discharge water 

in a hemispherical pattern below the sprinkler deflector.  
Residential distribution patterns are higher and generally 
contain a finer droplet size than standard sprinkler pat-
terns.

The combination of speed of operation and high dis-

charge pattern required for residential sprinklers has dem-
onstrated, in fire testing, an ability for controlling residen-
tial fires, and thereby providing significant evacuation time 
for occupants.

The RFC43 and RFC49 Sprinklers provide the best form 

of fire protection by combining an attractive appearance 
and ½” (13mm) of cover adjustment for ease of installa-
tion.  The small diameter cover plate is easily and posi-

1.
2.
3.

4.
5.

1.

2.

tively attached and blends into the ceiling, concealing the 
most dependable fire protection available, an automatic 
sprinkler system.

The RFC43 and RFC49  are UL Listed Residential Sprin-

klers to be installed in the residential portions of any occu-
pancy in accordance with NFPA 13, 13R, & 13D.

The RFC43 and RFC49 can reduce the need for precise 

cutting of drop nipples.  The threaded cover plate assem-
bly can be adjusted without tools to fit accurately against 
the ceiling.  The fire protection system need not be shut 
down to adjust or remove the cover plate assembly.

Application and Installation

The RFC43 and RFC49, for residential installations, use a 

165°F (74°C) fusible solder link in a tuning fork style sprin-
kler frame with a drop-down deflector.  This assembly is re-
cessed into the ceiling and concealed by a flat cover plate.  
The cover plate is attached to the skirt, using 135°F (57°C) 
ordinary temperature classification solder. When the ceil-

Reviews: