The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory
Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries.
The Reliable Automatic Sprinkler Co., Inc.
(800) 431-1588
Sales Offices
(800) 848-6051
Sales Fax
(914) 829-2042
Corporate Offices
www.reliablesprinkler.com
Internet Address
Revision lines indicate updated or new data.
E.G. Printed in USA 08/04
P/N 9999970168
Recycled
Paper
Manufactured by
concealed cover plate assembly on any sprinkler with
which it is not specifically listed may prevent good fire
protection and will void all guarantees, warranties, listings
and approvals.
Maintenance
Model F1FR-300/CCP Concealed Sprinklers should be
inspected quarterly and the sprinkler system maintained in
accordance with NFPA 25. Do not clean sprinklers with
soap and water, ammonia or any other cleaning fluids.
Remove dust by using a soft brush or gentle vacuuming.
Remove any sprinkler cover plate assembly which has
been painted (other than factory applied) or damaged in
any way. A stock of spare sprinklers should be maintained
to allow quick replacement of damaged or operated
sprinklers.
Prior to installation, sprinklers should be
maintained in the original cartons and packaging until
used to minimize the potential for damage to sprinklers
that would cause improper operation or non-operation.
two cover plate assemblies provide either ½" (13mm) or
5
16
" (8mm) of cover adjustment.
Do not install these sprinklers in ceiling which have
positive pressure in the space above.
After a 2
5
8
" (67mm) diameter hole is cut in the ceiling,
the sprinkler is easily installed with the Model RC1 Wrench.
A Teflon*-based thread sealant should be applied to the
sprinkler threads only. The Model RC1 Wrench is then
used to engage the sprinkler wrenching surfaces and to
install the sprinkler in the fitting.
When inserting or
removing the wrench from the sprinkler/cup assembly, DO
NOT WRENCH ON ANY OTHER PART OF THE
SPRINKLER. The cover plate is then pushed onto the cup.
Final adjustment is made by hand turning the cover plate
until the skirt flange makes full contact with the ceiling.
Cover plate removal requires turning in the counter
clockwise direction.
After installation, inspect all sprinklers to ensure that
there is a gap between the cover plate and ceiling and that
the four cup slots are open and free from any air flow
impediment to the space above.
Concealed cover plate/cup assemblies are listed only
for use on specific sprinklers.
The use of any other
concealed cover plate/cup assembly with the Model
F1FR-300 Pendent Sprinkler or the use of the Model CCP
Nominal
Orifice Size
Thread Size
Nominal
K Factor
Temp. Rating
Max.
Ambient
Temp.
Bulb
Color
Sprinkler
Identification
Number (SIN)
US
Metric
Sprinkler
Cover
½
²
(15mm)
½
²
NPT (R½)
5.6
80
135
°
F/57
°
C
135
°
F/57
°
C
100
°
F/38
°
C
Orange
R5615
½
²
(15mm)
½
²
NPT (R½)
5.6
80
155
°
F/68
°
C
135
°
F/57
°
C
100
°
F/38
°
C
Red
½
²
(15mm)
½
²
NPT (R½)
5.6
80
175
°
F/79
°
C
165
°
F/74
°
C
150
°
F/66
°
C
Yellow
½
²
(15mm)
½
²
NPT (R½)
5.6
80
200
°
F/93
°
C
165
°
F/74
°
C
150
°
F/66
°
C
Green
8. Cover Plate Temp Rating:
9. 135
°
F (57
°
C) for 135
°
F and
155
°
F Spks; 165
°
F (74
°
C) for
175
°
F and 200
°
F Spks.
10.Cover plate adjustment:
Either ½
²
(13mm) or
5
16
²
(8mm)
(approximate adjustment).
11.Cover Plate Finish.
Standard Finishes
Chrome
White Paint
Special Application Finishes
Bright Brass
Black Plating
Black Paint
Off White
Satin Chrome
Cover Plate Finishes
(1)
(1)
Other colors and finishes
are available. Consult
factory for details.
Figure 1
Figure 2
*DuPont Registered Trademark
Technical Data
Ordering Information
Specify:
1. Sprinkler Model F1FR-300
½
²
Orifice (15mm),
2. ½
²
NPT (R½).
3. Sprinkler Temp. Rating:
4. 135
°
F (57
°
C), 155
°
F (68
°
C),
5. 175
°
F (79
°
C), 200
°
F (93
°
C).
6. Cover Plate: Model CCP.
7. Sprinkler Cup Thread Size:
½
²
NPT (R½).
Installation Wrench
Model RC1 Sprinkler Wrench
Installation Aid
A protective cap is included
for use during installation.