Reliable DH80 Dry Manual Download Page 12

Reliable Automatic Sprinkler Co., Inc.

(800) 431-1588    

Sales Offices

(800) 848-6051    

Sales Fax

(914) 829-2042    

Corporate Offices

www.reliablesprinkler.com   Internet Address

Manufactured by

Recycled

Paper

Revision lines indicate updated or new data.

EG. Printed in U.S.A. 09/21

P/N 9999970486

The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual 

Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years.

Ordering Information

Specify:

1. 

Sprinkler: Model DH80 Dry

2. 

Escutcheon/Cover Plate Model: [Standard escutcheon]
[Model  HB  extended  escutcheon][Model  FP  recessed 
escutcheon][Model SWC cover plate]

3. 

Sprinkler  Temperature  Rating:  [155°F  (68°C)][175°F 
(79°C)][200°F (93°C)]

4. 

Sprinkler threads: [1” NPT][ISO7-1R1]

5. 

Sprinkler  inlet:  [Standard][Short  “PL”  -  wet-pipe 
installation only]

6. 

Sprinkler/Escutcheon Finish: See Finishes table

7. 

Cover Plate Finish (where applicable): See Finishes table

8. 

Length:  “A”  Dimension  (face  of  tee  to  finished  face  of 

wall in 1/4” (6 mm) increments up to a maximum of 36” 
(900 mm)- See Fig. 4-7)

Note:

 The “A” dimension is based on a  nominally gauged 

pipe thread “make-up” of 0.600” (15 mm) per ANSI B2.1 
(approx. 7-1/2 threads). 

Installation Wrench

Model F3R Sprinkler Wrench (Standard and HB escutcheons)
Model XLO2 Sprinkler Wrench (FP Recessed and SWC 
Concealed)

Summary of Contents for DH80 Dry

Page 1: ...Light Hazard occupancies Patents US Patent No 7 841 418 Products Description The Model DH80 Dry sprinkler is a quick response extended coverage horizontal sidewall sprinkler for use in Light Hazard ap...

Page 2: ...ate occurs when the solder melts due to an increase in the surrounding temperature allowing the cover plate to fall away and exposing the Model DH80 Dry sprinkler Model SWC cover plates are available...

Page 3: ...al throw Sprinklers shall have standard escutcheons extended escutcheons recessed escutcheons conical concealed cover plates produced by the manufacturer of the sprinklers and cULus Listed for use wit...

Page 4: ...ot less than 4 102 mm or more than 12 305 mm from the finished ceiling A hole must be cut in the wall directly in line with the outlet of the tee See the Installation Data table for the recommended ho...

Page 5: ...Stainless Steel Bronze Laquered Brass Chrome Polished Stainless Steel White Polyester 1 White Polyester 4 Black Polyester 1 Black Polyester 4 Custom Color Polyester 1 Custom Color Polyester 4 Electrol...

Page 6: ...Sprinkler Escutcheon 2 3 Bronze Chrome Chrome Chrome White Polyester 1 White Polyester Black Polyester 1 Black Polyester Custom Color Polyester 1 Custom Color Polyester Electroless Nickel PTFE 1 Stain...

Page 7: ...ite Polyester 2 White Polyester Black Polyester 2 Black Polyester Custom Color Polyester 2 Custom Color Polyester Electroless Nickel PTFE 2 Stainless Steel Notes 1 Cup for FP Recessed is unfinished ga...

Page 8: ...r 1 connections Finish Combinations SWC Concealed Cover Plate Sprinkler 1 Cover Plate 2 Bronze White Polyester Chrome Bright Chrome Dull Bright Brass Unfinished Bronze Black Plate Custom Color Notes 1...

Page 9: ...Fig 8 9...

Page 10: ...10 Fig 9...

Page 11: ...11 Fig 11...

Page 12: ...property for almost 100 years Ordering Information Specify 1 Sprinkler Model DH80 Dry 2 Escutcheon Cover Plate Model Standard escutcheon Model HB extended escutcheon Model FP recessed escutcheon Model...