Parameterization
TR-Electronic GmbH 2013, All Rights Reserved
Printed in the Federal Republic of Germany
Page 114 of 175
TR - ECE - BA - DGB - 0102 - 09
01/17/2019
7.1 Overview of available classes
Object Classes
Purpose
Access
Page
0x01: Identity Object
Contains all device specific data, such as
Vendor ID, Device type, Device status etc.
Get
0x02: Message Router Object
Contains the measuring system’s supported
class codes and the max. number of
connections.
Get
*
0x04: Assembly Object
Returns the position value of the measuring
system.
Get
0x06: Connection Manager Object
Contains connection specific attributes for
triggering, transport, connection type etc.
Get
*
0x23: Position Sensor Object
Contains all attributes for programming the
measuring system parameter, such as
scaling and count direction.
Set/Get
0x47: Device Level Ring Object
DLR contains attributes for the status
information of the ring bus system.
Get
0x48: Quality of Service Object
QoS is a general term for mechanisms that
treat traffic streams with different relative
priorities or other delivery characteristics.
Therefore the EtherNet/IP
™ messages are
marked with “Differentiated Services Code
Points“ (DSCP)
Set/Get
0xF4: Port Object
Contains the available Ports, Port name and
Node address on the port.
Get
*
0xF5: TCP/IP Interface Object
Contains all attributes for the configuration
of the TCP/IP network interface such as IP
address, Subnet mask and Gateway.
Defines how the measuring system gets
these parameters: FLASH, DHCP or
hardware switch.
Set/Get
0xF6: Ethernet Link Object
Contains connection specific attributes,
such as Transmission rate, Interface status
and the MAC-Address.
Get
Table 8: Overview of available classes
* corresponds to EtherNet/IP
™ specification