THERMOJET
®
G-5700E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740153
Rev
1
Date
June 2020
Page
33
of
90
Ensure that the ThermoJet Oil Purifier Circuit Breaker and the ON-OFF Selector Switch both are
in the OFF position.
Turn “ON” electrical power at the energy source breaker.
Turn the Circuit Breaker handle to the ON position. Use the ON-OFF Selector switch to jog the
electric motor and check proper motor rotation. Verify the motor rotation against the directional
arrow located on drive end of the motor.
If incorrect, place the Circuit breaker in the OFF position and disconnect supply power at the
source.
NOTICE:
Recycle all drained oils.
Ensure that all sources of electrical power are
disconnected before opening the controller.
Failure to do so may result in serious injury or
even death
.