Rejuvenation RIGDON Manual Download Page 4

 

INSTALLTION FOR 

MINIATURE THERMOSTATIC VALVE

 

 

Rev. 8/19 

 

 

P a g e

 | 

3

 

Diagram 4: Representative Trim 

 

Parts Checklist 

Carefully remove all parts from the box. The following parts should be included. 

Item # 

Description 

Qty.    Item # 

Description 

Qty. 

Temperature Control Dome 

 

Temperature Control Screw 

Dome Sleeve (raw brass) 

 

Temperature Control Handle 

Face Plate 

 

Volume Control Dome 

Lock Ring 

 

10 

Volume Control Post 

Temperature Limit Stop Ring 

 

11 

Volume Control Screw 

Temperature Control Post 

 

12 

Volume Control Handle 

 

 

Temperature Setting 

The delivered temperature of the valve varies depending on the temperature of the supplied hot water. The 
valve  is  factory  set  at  a  supplied  temperature  of  149°F  under  balanced  pressures.  Depending  on  your 
preferred  hot  water  temperature  setting,  it  may  be  necessary  to  adjust  the  calibrations  of  the  valve.  The 
limit override button is preset at 100°F and can be adjusted as described below. 

 

1.

 

Select 100°F on the control handle. 

2.

 

Without turning the handle, remove the handle by unscrewing the screw and pulling off (screw may 
be concealed and/or fastened with set screws). 

3.

 

Use a thermometer to check the delivered temperature on one of the outlets.   

4.

 

Adjust water temperature to 100°F by hand turning the cartridge stem slowly left or right. 

5.

 

Ensure that the temperature limit stop-

ring in installed with red dot at 12 o’clock position.

 

6.

 

Push  the  handle  back  on  the  valve  with 

the  push  button  at  the  12  o’clock  position

  and  fasten  in 

place. 

    

Diagram 5: Temperature Limit Stop Ring

 

 

RED DOT 