INSTALLTION FOR
MINIATURE THERMOSTATIC VALVE
Rev. 8/19
P a g e
|
3
Diagram 4: Representative Trim
Parts Checklist
Carefully remove all parts from the box. The following parts should be included.
Item #
Description
Qty. Item #
Description
Qty.
1
Temperature Control Dome
1
7
Temperature Control Screw
1
2
Dome Sleeve (raw brass)
2
8
Temperature Control Handle
1
3
Face Plate
1
9
Volume Control Dome
1
4
Lock Ring
2
10
Volume Control Post
1
5
Temperature Limit Stop Ring
1
11
Volume Control Screw
1
6
Temperature Control Post
1
12
Volume Control Handle
1
Temperature Setting
The delivered temperature of the valve varies depending on the temperature of the supplied hot water. The
valve is factory set at a supplied temperature of 149°F under balanced pressures. Depending on your
preferred hot water temperature setting, it may be necessary to adjust the calibrations of the valve. The
limit override button is preset at 100°F and can be adjusted as described below.
1.
Select 100°F on the control handle.
2.
Without turning the handle, remove the handle by unscrewing the screw and pulling off (screw may
be concealed and/or fastened with set screws).
3.
Use a thermometer to check the delivered temperature on one of the outlets.
4.
Adjust water temperature to 100°F by hand turning the cartridge stem slowly left or right.
5.
Ensure that the temperature limit stop-
ring in installed with red dot at 12 o’clock position.
6.
Push the handle back on the valve with
the push button at the 12 o’clock position
and fasten in
place.
Diagram 5: Temperature Limit Stop Ring
RED DOT