Rejuvenation RIGDON Manual Download Page 3

 

INSTALLTION FOR 

MINIATURE THERMOSTATIC VALVE

 

 

Rev. 8/19 

 

 

P a g e

 | 

2

 

4.

 

Use the 

Plastic Mudguard (1)

 (part of the package) to position the 

Valve (2)

 in the wall.  This is done 

by checking the markings on the mudguard for the minimum/maximum settings which is 2 3/8” to 2 

7/8

” from the center of the valve inlets to the finished wall.

 

 

Diagram 2: Plastic Mudguard

 

 

 

5.

 

Connect the outlet pipe(s). Install tile stops/volume controls between the thermostatic valve and 
each device to be operated.

 

NOTE: 

Port marked V will output about 6.5 gpm and port marked D will put out about 4.5 gpm at 45 psi.

 

NOTE: 

Shared ports are only between ports marked D1 and D2 on the SS-TH80 valve.

 

Trim Installation 

(see Diagram 4)

 

1.

 

Screw 

Temperature Control Dome (1)

 and 

Volume Control Dome (9) 

onto valve. 

 

NOTE: 

The 

Temperature Control Dome (1)

 has a larger opening than the 

Volume Control Dome (9).

 

2.

 

Slide the 

Thermostatic Face Plate (3)

 onto the valve by sliding over the 

Temperature Control Dome 

(1) 

and 

Volume Control Dome (9) 

and hold in place. 

3.

 

Screw 

Lock Rings (4) 

into 

Dome Sleeves (2)

4.

 

Lock the 

Thermostatic Face Plate (3)

 securely against the wall by screwing 

Dome Sleeves (2) 

with 

Lock Rings (4) 

onto 

Temperature Control Dome (1) 

and 

Volume Control Dome (9)

5.

 

Ensure 

Temperature Limit Stop Ring (5) 

is installed with 

red dot at 12 o’clock position

 

6.

 

Install 

Temperature Control Post (6)

 onto valve 

with push button at 12 o’clock position

 and install 

Temperature Control Handle (8) 

onto 

Temperature Control Post (6)

Note:

 Some heavier lever handles come with friction washers to prevent rotation due to gravity. The 

thicker of these washers is for use with this valve when needed (see Diagram 3). 

7.

 

Install 

Volume  Control  Post  (10)

  onto valve  and  install 

Volume  Control  Handle  (12) 

onto 

Volume 

Control Post (10)

 

Diagram 3

 

 

                     

Reviews: