  Specific Safety Instructions 

  The SONIRET Ultrasonic cleaning unit is exclusively destined for cleaning items and 

must not be operated without liquid in the bath. 

  Do not pour hot water into the bath. The heating shall only be used for heating cleaning 

fluid. 

  Add the required dose of cleaning additive! 

  The unit may not be operated permanently at maximum temperature. 

  Never use flammable solutions. Danger of fire and explosion! 

  Depending on the operating time 

the device’s surface, cleaning fluid, cleaning basket and 

cleaned items may become very hot. Danger of scalding! 

  Never expose hands to cleaning solutions or items during cleaning process (cleaning 

tank, basket, items to be cleaned, etc.). Danger, among others, of cracking finger nails. 

  We assume no liability for damage to persons, the unit or items to be cleaned, caused by 

subjecting the bath to improper treatment or misuse. 

  Installation in a special protective cabinet may be useful when operating the unit at high 

temperature or when using certain cleaning additives. 

 

Attention:

 

  Switch off the device before repair 

  Repairs only by qualified personnel 

  Use goggles, do not use toxic / flammable substances 

 

 

Summary of Contents for SONIRET

Page 1: ...Operating Instructions LABORATORY EQUIPMENT IN STAINLESS TEEL SONIRET REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel com ...

Page 2: ...wed by all personnel who use this device After having unpacked the device please check carefully whether transportation damages of any kind have occurred If that is the case the carrier or manufacturer must be notified within 3 days The company will not be responsible for any damages found after that These operating instructions must be read and followed by all personnel who use this device Store ...

Page 3: ...CCESSORIES 4 OPERATING ELEMENTS 4 TECHNICAL DATA 5 SAFETY NOTES 6 GENERAL SAFETY NOTES 6 SPECIFIC SAFETY INSTRUCTIONS 7 INSTALLATION 8 OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE 9 WARRANTY 10 RULES FOR DISPOSAL 13 SPARE PARTS LIST 13 EC CONFORMITY DECLARATION 14 ...

Page 4: ...inless steel positioning cover for beakers and round insert baskets Order No 20404000 Insert basket round stainless steel D 60 m Order No 20405000 Insert basket round plastic D 60 mm Operating elements 1 Housing 2 Power switch 3 Ultrasoundl 4 Heating 5 a b Temperature control cleaning temperature setting 6 a b Timer cleaning time setting 7 Cleaning time display min 8 Temperate display C 9 Protecti...

Page 5: ... consumption 200 W Tank dimensions height width depth 100 240 140 mm Device dimensions height width depth 210 280 190 mm Weight 4 5 kg Frequency 40 KHz Sound level 70 dB A Housing Stainless steel Order No 10200000 Made in Germany Subject to modifications ...

Page 6: ...facturer s warranty expires The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces should be straight flat and adequately stable Don t place anything on top of the machine To avoid injury appropriate protection should be worn e g gloves safety glasses safety shoes hearing protection etc If the machine is defective or working improperly it must be ...

Page 7: ...rface cleaning fluid cleaning basket and cleaned items may become very hot Danger of scalding Never expose hands to cleaning solutions or items during cleaning process cleaning tank basket items to be cleaned etc Danger among others of cracking finger nails We assume no liability for damage to persons the unit or items to be cleaned caused by subjecting the bath to improper treatment or misuse Ins...

Page 8: ...e main switch 2 to start the device 3 Put the items to be cleaned in the metal basket and place the basket in the cleaning bath 4 Set the required cleaning temperature 20 80 C use arrow key 5a to increase cleaning temperature use arrow key 5b to decrease cleaning temperature Use key 4 to activate heating 5 Set cleaning time normally 3 30 min depending on degree of item contamination Use arrow key ...

Page 9: ...mperature settings 2 Use cleaning liquid Short circuit If water penetrates the housing switch off device and pull the plug Please contact the customer service Maintenance Regularly check the condition of the device Pay attention to visible damage to housing or power cord Regularly remove dust deposits on the cooling fan cover of the ultrasound source Regularly check the bottom plate of the cleanin...

Page 10: ...essed to the distributor the product was purchased from or directly to our service department Contact REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 32 Service Department Phone 49 0 5472 9432 0 Reception Fax No 49 0 5472 9432 40 2 In case of warranty claim application the sales receipt or your purchase invoice showing the date of purchase of the product and th...

Page 11: ...mages due to faulty installation or insufficient maintenance of the product e g decalcification Damages due to natural disaster e g lightning water fire act of nature beyond control war inadequate line voltage insufficient ventilation no decalcification insufficient care and cleaning or non adherence to operation and maintenance instructions according to the accompanying operation guide Damage due...

Page 12: ... backup essential programs and data before sending for service 12 This warranty shall be interpreted in accordance with German law to the exclusion of UN sales law Place of jurisdiction is our business location 13 If any provisions of this warranty are judged to be illegal or unenforceable the continuation in full force and effect of the remaining provisions will not be prejudiced The provisions o...

Page 13: ... Best Nr Ref Menge Qty ME Unit E6296810 Frontfolie selbstklebend Self adhesive front foil 1 St pc E6299500 Hauptplatine 1 St pc E6276000 Lüfter 50 x 50 x 15 mm Fan 50 x 50 x 15 mm 1 St pc E7146320 Moosgummiprofil zur Deckel Dämpfung Foam rubber profile for lid attenuation 0 5 m E6064800 Schalter grün Green switch 1 St pc E6276100 Sicherung 0 5 A flink Fuse 0 5 mm fast 1 St pc E6299600 Steuerplatin...

Page 14: ...14 EC Conformity Declaration ...

Page 15: ......

Page 16: ...mpliance with Quality Management ISO 9001 2015 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel com 112019 ...

Reviews: