Z.-Nr.: 
Dr.-No.: 

Best.-Nr.: 
Ref.: 

 

Menge 
Qty. 

ME 
Unit 

 

E60229.3  Dichtung / seal 

St./pc. 

  

E60229.4 

Deckel mit Dichtung (Version aktuell) / Lid with seal 
(current version) 

St./pc. 

  

E60229.3  Dichtung (Version aktuell) / Lid (current version) 

St./pc. 

  

E76296 

Drehknauf / Knob 

St./pc. 

  

E62140.1 

Druckminderer (Version aktuell) / Pressure reducing 
valve (current version) 

St./pc. 

  

E62998 

Druckschalter 0,2 - 3 bar Einstellung 1,4 bar 1/8" 
oder 1/4" / Pressure switch 

St./pc. 

  

E62218 

Durchflussbegrenzer (Version ab 08.2008) / Flow 
limiter (version from 08.2008) 

St./pc. 

  

E70491 

Feinsicherung / Fine fuse 

St.pc. 

  

E60231 

Gehäuse komplett / Complete housing 

St./pc. 

  

E70496 

Gerätestecker mit Sicherungshalter / Device's plug 
incl. fuse holder 

St./pc. 

  

E60203 

Gummifüße / Rubber feet 

Satz/set 

  

E60227 

Gummitülle / Rubber sleeve 

St./pc. 

  

E60229.1  Ionentauscher / Ion exchanger 

St./pc. 

  

E74134 

Kontrolllampe rot, rund / Red control lamp 

St./pc. 

  

E72139.1 

Magnetventil 1/8" NW 3 mm / Solenoid valve 1/8" 
NW 3 mm 

St./pc. 

  

E60940 

Mikroschalter (Version aktuell) / Micro switch 
(current version) 

St./pc. 

  

E60229.5  Mutter / Nut 

St./pc. 

  

E60648 

Schalter 2-polig mit Lampe grün / 2-pole switch with 
green lamp 

St./pc. 

  

E60207 

Schaltwerk komplett (Version aktuell), incl. 76294 / 
Complete control unit  (current version), incl. 76294 

St./pc. 

  

E60650 

Schutzkappe für Schalter / Protective cap for switch  1 

St./pc. 

  

E60204 

Wasserauffangblech / Water drip tray 

St./pc. 

  

E60232 

Wasserschlagdämpfer / Water hammer absorber 

St./pc. 

  

20201 

Wasserhahn für manuelle Wasserentnahme / Water 
tap  

St./pc. 

  

E60220 

Zulaufschlauch / Feeding hose 

St./pc. 

 

 

 

Summary of Contents for DELIMER COMFORT

Page 1: ...ating Instructions LABORATORY EQUIPMENT IN STAINLESS STEEL DELIMER COMFORT REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Tel 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com info reitel...

Page 2: ...lt thereby Prior to installation of the device operating instructions and especially the safety instructions must be read and followed by all personnel who use this device After having unpacked the de...

Page 3: ...HNICAL DATA 6 SAFETY NOTES 7 GENERAL SAFETY NOTES 7 SPECIFIC SAFETY NOTES 8 INSTALLATION 9 INSTALLATION 9 FILLING WITH REGENERATION SALT 9 OPERATION 9 START UP 9 REGENERATION 10 TROUBLESHOOTING 10 MAI...

Page 4: ...der No 20201 Water tap Order No 20202 Back pressure valve Device components 1 Housing 2 Main switch 3 Lid for salt container 4 Rotary switch for regeneration 5 Water connector for the supply line 6 Dr...

Page 5: ...5 Fig Device view Fig Rear view 1 10 2 3 9 4 8 5 6 7...

Page 6: ...mption 100 W Height Width Depth 434 327 294 mm Weight 11 kg Water pressure max 3 bar Mains water supply 3 5 l min Extracted water Kalkreduziertes Wasser 50 dH Sound level 70 dB A Housing Stainless ste...

Page 7: ...ons who have been instructed in the handling and are expressly commissioned with the operation The device should be set up in a clean well ventilated room if necessary under a hood Supporting surfaces...

Page 8: ...8 Specific Safety Notes Install the appliance so that damage is prevented in the event of unwanted water leakage...

Page 9: ...ration salt When using the appliance for the first time or when the regeneration salt indicator 10 lights up in red regeneration salt needs refilling Prior to refilling empty water from the DELIMER CO...

Page 10: ...nerating salt quantity insufficient top refill regenerating salt according to chapter 3 2 Connection device calcified for example steam cleaner a No regenerating salt in the container b Regeneration f...

Page 11: ...ssed to the distributor the product was purchased from or directly to our service department Contact REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Germany Phone 49 0 5472 9432 32 Service Dep...

Page 12: ...than for its intended purpose Damages due to faulty installation or insufficient maintenance of the product e g decalcification Damages due to natural disaster e g lightning water fire act of nature...

Page 13: ...ind of data loss The customer is advised to backup essential programs and data before sending for service 12 This warranty shall be interpreted in accordance with German law to the exclusion of UN sal...

Page 14: ...1 St pc E60231 Geh use komplett Complete housing 1 St pc E70496 Ger testecker mit Sicherungshalter Device s plug incl fuse holder 1 St pc E60203 Gummif e Rubber feet 1 Satz set E60227 Gummit lle Rubb...

Page 15: ...15 EC Conformity Declaration...

Page 16: ...pliance with Quality Management ISO 9001 2015 incorporating established standards REITEL Feinwerktechnik GmbH Senfdamm 20 49152 Bad Essen Phone 49 0 5472 9432 0 Fax 49 0 5472 9432 40 www reitel com in...

Reviews: