Parameter 77

Activation lock time closing time 2

0 – normal mode
1 – closing time mode

Parameter 78

Activation lock time closing time 3

0 – normal mode
1 – closing time mode

Example : The motion sensor Outside is locked from 6 p.m. until 8 a.m.

1. Start 1:

(P70)

= 06:00:00 p.m.

2. End 1:

(P71)

= 08:00:00 a.m.

3. Closing time mode:

P(76)

= 1

Parameter 80:

New safety check interval, internal counters are reset

Parameter 81:

Maintenance interval in months

Parameter 82:

Accumulator operation in case of power failure

0 – normal operation for approx. one hour at 50 cycles

1 – door OPENS in case of power failure and remains in this position until power returns

2 – all holding functions are deactivated; the door

always

closes immediately after an opening run

Parameter 83:

Pull and Go Func tion

0 – door can

not

be operated manually. The door is kept closed by motor operation and an acoustic

signal warn s the user in case of manual opening.

1 – door can be manually operated. The door is opened by motor operation. The CompletelyOpen1

function is carried out.

2 – door can be manually operated. The door is opened by motor operation. The PartlyOpen func-

tion is carried out.

3 – door can be manually operated. The door is opened by motor operation. The PermanentlyOpen

function is carried out..

4 – door can be manually operated. The door opens automatically until the set opening width (pa-

rameter 15) is reached. The PermanentlyPartlyOpen function is carried out.

Parameter 84:

Safety elements:

0 – deactivated

1 – active

Parameter 85:

Number of safety elements:

1 – Operation with one safety element
2 – Operation with two safety elements

Parameter 86:

Self-monitoring function for safety element 1:

0 - deactivated
1 – active

Parameter 87:

Self-monitoring function for safety element 2:

0 – deactivated
1 – active

Parameter 88

Key lock time start – time when all operating elements are locked.

Parameter 89

Key lock time end – time when all operating elements are reactivated.

Example : The operating elements are locked from 4 p.m. until 6 a.m.

1. Start:

(P88)

= 04:00:00 p.m.

2. End:

(P89)

= 06:00:00 a.m.

Parameter 95

Enable program modules (5-digit);

1 – motion sensor
2 – safety elements
3 – interlocking function
4 – self-monitoring function for safety elements

5 – accumulator operation (emergeny power)

Summary of Contents for S 3000

Page 1: ...OPERATING INSTRUCTIONS SLIDING DOOR DRIVING MECHANISM S 3000 V1 38EN 19 12 05 ...

Page 2: ...th terminal plug in terminal 50 53 6 5 2 2 with notebook plug in terminal 1 3 6 5 2 3 with PARTLYOPEN key plug in terminal 6 7 6 5 3 Fault clearance during putting into operation procedure 7 6 0 Features 7 6 1 Standard feature 7 6 2 Optional features 7 6 3 Safety features 7 7 0 Maintenance Safety check 8 8 0 Fault clearance 8 8 1 Error code 8 9 0 Parameters 9 9 1 Parameter list Terminal RS232 9 9 ...

Page 3: ...t users of a door system The appropriate operating instructions serve as an aid 2 0 Product description 2 1 Designation Model DIN left or DIN right right left handed opening S 3000 one wing S 3000 two wing S 3000 telescopic 2 2 Design Standard up to 150 kg Heavy SK up to 250 kg Hermetic HE up to 150 kg 2 3 Driving mechanism Sliding rail and trolley are made of anodized alu minium profile The troll...

Page 4: ... Acceptance of the selected parame ters functions P Three functions can be activated 1 Change over from main level to parameter level and vice versa 2 Abort at parameter or PS level 3 Position change in password or date time input and have two functions 1 Selection of the parameter number or the parameter value 2 Selection of the PS function 2 5 4 Parameter settings The parameters are preset at wo...

Page 5: ...r value here 12s Display after pressing E key 2 5 5 Programm selector The following modes are available 1 Permanently open 2 Closing time 3 Winter mode 4 Electrical lock 5 Winter mode and closing time 6 Manual mode Example PS mode Closing time Standard display PS inactive Parameter 61 select 1 Display PS mode Use the or key to select the desired mode here Closing time Use the E key to ac cept this...

Page 6: ...f the manufacturer for damages resulting therefrom 4 0 Assembly Only authorized technical staff is allowed to carry out the assembly of the driving mechanism The compulsory in struction on our premises is the basis for proper assem bly The instruction material includes all instructions re quired for assembly 5 0 Putting into operation The setting up of the driving mechanism for the putting into op...

Page 7: ...external door is possible As soon as one door is open opened the locking moni toring device will prevent another door belonging to the interlock from being opened A signalling optical acoustic of the interlock state via CHK1 terminal 59 60 unlocked and CHK2 terminal 57 58 interlocked is possible only with module 4 being inactive The max total out put current of the switchable outputs CHK1 2 is 0 4...

Page 8: ...cessary to unplug the mains plug thus interrupting the power supply 8 0 Fault clearance The sliding door driving mechanism continuously carries out self diagnoses and adjusts itself automatically In case of values beyond the set value range error messages are displayed The error is indicated via the termi nal in plain text and as a colour code of the LEDs installed at the driving unit at the same ...

Page 9: ...1 end closing time Lock time 1 end closing time Format hh mm ss 17 Running in OPEN Running in zone OPEN 50 200 mm 70 72 Lock time 2 start closing time Lock time 2 start closing time Format hh mm ss 18 Running in CLOSE Running in zone CLOSE 50 200 mm 70 73 Lock time 2 end closing time Lock time 2 end closing time Format hh mm ss 19 Safe distance Safe distance 0 30 mm 10 74 Lock time 3 start closing...

Page 10: ...partial opening Parameter 2 Open time in seconds for complete opening 1 Parameter 3 Open time in seconds for motion sensor Inside Parameter 4 Open time in seconds for motion sensor Outside Parameter 5 Open time in seconds after reversing Parameter 6 Open time in seconds for complete opening 2 Parameter 7 Delay time until activation of electrical lock Parameter 8 Automatic start 0 door starts after...

Page 11: ...increased risk of injury Parameter 33 The acceleration slope ensures a smooth starting of the door without any jerks The works setting of the parameter value is 400 It should only be modified with care Smaller values signify a steeper slope i e the door is accelerated faster greater values signify a more gentle slope i e the door is accelerated less fast Attention This parameter affects the servic...

Page 12: ...K1 as NO contact 0 or NC contact 1 K1 is activated at each opening of the door Parameter 59 1 after reversing door remains in open position until time parameter 5 has elapsed 0 after reversing door remains in open position until a key is pressed Parameter 60 Status display Parameter 61 Program selector 0 deactivated 1 active Parameter 62 All parameters are reset back to works settings according to...

Page 13: ...unction is carried out 2 door can be manually operated The door is opened by motor operation The PartlyOpen func tion is carried out 3 door can be manually operated The door is opened by motor operation The PermanentlyOpen function is carried out 4 door can be manually operated The door opens automatically until the set opening width pa rameter 15 is reached The PermanentlyPartlyOpen function is c...

Page 14: ...ms Accessories Windows 98 ME XP 10 1 Configuration Before the first start the following link settings must be entered Enter link name and select link Select link Enter linking features Select font and size Other settings Complete data link Plug in data cable terminal 1 3 and connect it to the PC 9pole D Sub at the serial interface RS 232 Important The sliding door must be closed during data commun...

Page 15: ... V 1 380 S N 0401001 MType STANDARD 41 Date 14 03 05 61 Program selector 0 42 Time 09 46 47 62 Works setting 43 Summertime 0 63 Lighting frame 0 44 64 Relay K2 1 45 65 Acoustic signals 1 46 66 Autom holding open 0 47 67 48 68 49 69 50 Teach in run 70 Lock time 1 Start Closing time 00 00 00 51 Special function 0 71 Lock time 1 End Closing time 00 00 00 52 Teach in run without speed test 72 Lock tim...

Page 16: ... 16 11 0 Terminal diagrams 11 1 Cable laying diagram ...

Page 17: ...51 05 17 11 2 Terminal assignment ...

Page 18: ... 18 12 0 Dimensions 12 1 Sectional drawing one wing drive ...

Page 19: ...51 05 19 12 2 Sectional drawing telescopic and two wing drive ...

Page 20: ... 20 Reisinger GmbH Unterschöllenbacher Straße 1 90562 Kalchreuth Tel 49 0 911 956 80 70 Fax 49 0 911 956 80 72 www reisinger de info reisinger de ...

Reviews: