Manual

MWS 3 & 485-Sensors

 with Microprocessor 

without datalogger

REINHARDT

 System- und

Messelectronic GmbH

Bergstr. 33, D-86911 Dießen-Obermühlhausen

Tel. 0049 - (0) 8196/934100    Fax 0049 - (0)8196/7005 or 1414

E-Mail: 

[email protected]

http://www.reinhardt-wetterstationen.de

Summary of Contents for 485 Series

Page 1: ...rocessor without datalogger REINHARDT System und Messelectronic GmbH Bergstr 33 D 86911 Dießen Obermühlhausen Tel 0049 0 8196 934100 Fax 0049 0 8196 7005 or 1414 E Mail wetter reinhardt testsystem de http www reinhardt wetterstationen de ...

Page 2: ...2 The Humidity sensor MWS 3 DFT 485 and FTS 485 8 3 2 3 The Pressure sensor MWS 3 DFT 485 und DTS 485 8 3 2 4 The Wind Speed sensor 9 3 2 5 The Wind Direction sensor 9 3 2 6 The Clouds sensor WKS 485 9 3 2 7 The light intensity sensor HKS 485 10 3 2 8 The Global radiation sensor GSS 485 10 3 2 9 The Ultraviolet radiation sensor UVS 485 10 3 2 10 The UVI radiation sensor UVIS 485 10 3 2 11 Der Rain...

Page 3: ...h RS422 port 16 5 Excerpts from the Directions of DWD for Automatic Weather Stations 17 6 Trouble Shooting 18 6 1 Fault Protocol File 16 bit versions 18 6 2 Protocol files 32 bit versions 18 6 2 1 Log file in case of error ErrLog txt 18 6 2 2 Logfile when starting up log dat 18 7 Options 19 7 1 Available displays 19 7 2 1 Meteograph 19 7 2 2 DKA1 19 7 2 3 DMMK 19 8 Technical Appendix 20 8 1 Contro...

Page 4: ... 2015 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de MWS 3 WGWR 485 WGS 485 WRS 485 DFT 485 FTS 485 DTS 485 WKS 485 HKS 485 GSS 485 UVS 485 UVIS 485 RDR 485 ...

Page 5: ...We shall not assume any liability for subsequent damage We shall not assume any liability for damage of items or persons caused by improper handling or non observance of the safety instructions In such cases any guarantee claims shall become null and void Dear customer the following safety and hazard notices not only serve the protection of your health but also the protection of the appliance Plea...

Page 6: ...rections of DWD If you haven t ordered a ready made cable you need to build a cable with the attached connectors by yourself For power supply you need a voltage between 6 an 30VDC and at least 20mA Connect the cable as follows Connect the 9pole connector to a free serial interface of your PC COM1 COM2 Plug in the power supply into a power outlet 230V 50Hz or connect a solar panel with accumulator ...

Page 7: ...disabled so that you can request a data string when ever you want When using RS485 then this is the basically operation More details you ll find under chapter 8 technical appendix 3 Technical details For the MWS 3 hasn t got a data logger the software needs to run permanently to get gapless weather data 3 1 Maintenance Because of its elaborated sensors the MWS 3 needs no maintenance Our warranty e...

Page 8: ...It is linearized to an accuracy of 2 5 between 10 and 90 relative humidity at 25 C Range from 10 to 100 measuring accuracy 2 5 between 10 and 90 relative humidity display also as dewpoint meas ure ment in C or F Unit NOTE Thissensorisveryresponsivetostaticchargeandairpollution dust aggressivegases butalsosalt Please note that under unfavourable conditions i e microbic stress caused by moulds bacte...

Page 9: ...60 for measuring wind direction Wind direction is given in with 90 being East 180 being South 270 being West and 0 being North Range in 360 measuring accuracy 5 starting speed 0 8 m s hysteresis 5 Output is performed as WR winddirection Unit 3 2 6 The Clouds sensor WKS 485 The Cloudssensor detects if there are clouds or not using a thermopile If the sensor detects clouds in it s field of view the ...

Page 10: ...m with maximum sensitivity at 330nm 3 2 10 The UVI radiation sensor UVIS 485 directly measures the UV Index erytemal action spectrum with the maximum at 297nm The measuring range is between 0 and 12 UVI 3 2 11 Der RainDetectionRadar sensor RDR 485 is a maintenance free detector using a 24GHz Doppler Radar for detecting rain and hail To avoid errors in detecting the sensor must have free sight at t...

Page 11: ...om 40 to 60 resolution 0 01 C 16bit Relative humidity f from 10 to 100 resolution 0 01 16 bit Dewpoint from 40 to 60 resolution 0 01 C Absolute pressure from 300 hPa to 1100hPa in 0 03 hPa resolution 16 bit Wind direction 0 to 360 resolution 0 3 10 bit Wind speed in km h from 0 to 200 km h with 0 05 km h resolution Light intensity in lux from 0 to 220000 lux with resolution of 4 lux UV A 0 to 5000...

Page 12: ...V 12V 18V 24V MWS 3 19mA 9 7mA 6 8mA 5 2mA DFT 485 2 4mA 1 3mA 0 9mA 0 7mA WGS 485 7 0mA 3 9mA 3 2mA 2 8mA WKS 485 3 2mA 1 6mA 1 1mA 0 9mA GSS 485 5 7mA 2 8mA 1 9mA 1 5mA HKS 485 4 5mA 2 3mA 1 6mA 1 2mA UVIS 485 5 6mA 2 9mA 2 0mA 1 6mA 3 4 2 Power consumption The typical power consumption with RS 232 at 18VDC is MWS 3 6 8mA power consumption 122mW DFT 485 800µA power consumption 16mW WGS 485 3 2mA...

Page 13: ...e sensor TD temperature TE barometer DR and humidity FE The datastring ends with CR LF The data format of WGS 485 looks like this Example of a datastring WG9 13 WS18 23 WD12 23 Every second the WGS 485 transmits a data record which includes the measured values separa ted by comma the single measured values with sensor identification come in the following order Current wind speed WG windpeak since ...

Page 14: ...avoid acciden tally setting the sensor to RS232 mode what would lead to malfunction of the sensor and the need to open it The write protection can be removed in the SECURE mode of the sensor See 8 1 1 Input parameters of MWS 3 485 Sensors Microcontroller 3 5 2 RS485 port The format of the data is the same as described above with RS 232 RS422 But note that with RS485 the sensor always is tristate a...

Page 15: ... connection 9 pole interface connector Pin 1 GND Pin 5 GND Pin 2 GND used for MWS 9 5 Pin 3 RXD MWS 3 Pin 3 TXD PC Pin 4 TXD MWS 3 Pin 2 RXD PC Pin 5 VCC 18VDC Pin 6 R with RS422 485 Pin 7 T with RS422 485 Connect Pin 4 and 6 Connect Pin 7 and 8 The data cable can be lengthened to up to 50 m under optimum conditions and with suited cable not in industrial environment In case you lengthen the data ...

Page 16: ...ystem de Web http www reinhardt wetterstationen de 4 1 2 Allocation of the Connection Cable for Sensors with RS422 port 7 pole connector MWS 3 power supply and data connection Pin 1 GND PSU GND grey Pin 2 GND used for MWS 9 5 Pin 3 R of MWS 3 wire yellow Pin 4 T of MWS 3 wire white Pin 5 VCC 18VDC PSU VCC pink Pin 6 R of MWS 3 wire green Pin 7 T of MWS 3 wire brown ...

Page 17: ...s if radio medium frequency transmitters are around 2 2 2 Measuring field The measuring field ought to be 10 x 10m but at least 6 x 6m 3 Sensors 3 1Measuring air temperature 200cm By standard air temperatur is measured 2m above ground In order to keep radiation errors as low as possible air temperature ought to be measured in a weather hut 3 4Measuring relative air humidity 200cm By standard relat...

Page 18: ... as it is overwritten whenever you restart the software Please see the files DOC or DOK too You will find important new information on the weather software which is not yet in this manual 6 2 Protocol files 32 bit versions 6 2 1 Log file in case of error ErrLog txt Softwareversions for sensorswithout logger same or newer than V2 26 writea log file ErrLog txt in case of errors dataerrors or tranmis...

Page 19: ... http www reinhardt testsystem de english climate_sensors additional_modules php 7 1 Available displays 7 2 1 Meteograph Precision analog display with high grade stepping motors For indoor use only 7 2 2 DKA1 LED mini display for alternating of up to 9 values 13 mm digit size 7 2 3 DMMK Small digital meteo display for displaying 10 parameters simultaneously with digit size 13 mm Available for wall...

Page 20: ... control Fx 0 x 255 Bit 7 not available Bit 6 Output of device address DA with CR LF in front of every data record Bit 5 on Reset of GE input with R off Reset of GE input with P Bit 4 not available Bit 3 not available Bit 2 not available Bit 1 not available Bit 0 not available Changing from measured value output and adjustment mode output of frequency W 13 Fading in out single sensors All availabl...

Page 21: ... respective sensor L SENSORNUMBER S Linearity summand 13 depends on the respective sensor L SENSORNUMBER O Temperature offset 13 depends on the respective sensor L SENSORNUMBER T Temperature coefficient 13 depends on the respective sensor Setting local altitude for display of barometric pressure O LOCALALTITUDE m 13 Resetting windpeak and average wind P 13 Toggle between outputmode and Securemode ...

Page 22: ...x00b RS232 MWS 3 transmits a data record every sec xxxxxx01b RS422 MWS 3 transmits a data record every sec xxxxxx10b RS485 MWS 3 is addressed and transmits on request xxxxxx11b not available xxxxx1xxb MWS 3 transmits on request only RS232 RS422 xxxx1xxxb not available xxx0xxxxb not available xxx1xxxxb not available xx1xxxxxb not available 1xxxxxxxb EEPROM write protection can only be disabled in S...

Page 23: ...nsors 8 2 2 Querying the Microprocessor Call the current data file U 13 Call linearisation data sensor configuration and system information 13 Call linearisation data for an explicite sensor 0 13 Only the info about the main configuration will be sent 1 13 Only the info about the configuration of the sensors will be sent 2 13 Only the info about the sensor 2 temperature will be sent and so on ...

Page 24: ...5 4 DR Pressure on hPa 6 5 RE Rain wind input off mm l m 7 6 GE Counter wind input off 8 7 WG Wind speed on km h 9 8 WR Wind direction on 10 9 ZB Additional 2 off mV 11 10 FE Humidity on 12 11 WS Wind peak on km h 13 12 WD Wind average on km h 14 13 OH Altitude off 15 14 LX Light intensity off lux Caution The pressure sensor uses the sensor Temperature of pressure sensor TD for compen sating the t...

Page 25: ...n case you have to replace connectors please contact Fa Adam Tel 49 0 8131 2808 51 The connectors belong to Series 711 Below you will find the order numbers 5way connector heating GPS 99 0095 102 05 7way connector data and power supply 99 0475 102 07 8way connector additional sensors 99 0479 102 08 Of course you can order the connectors also from REINHARDT I OE Specifications subject to change wit...