49

eading       a great experience!

Charging the batteries

Whenever MAXLUPE is switched off and supplied with tension via the power supply
unit, the batteries are being charged. 

State of charge of the batteries

For your information the state of charge of the batteries is indicated on the left side of the TFT
display. When switching MAXLUPE on (without power supply unit) a great battery symbol
appears.
The symbol of the battery indicates the state of charge: 
- completely full - the batteries are fully charged
- half full- the batteries are partly charged, and so on.
Approx. 3 seconds after switching the system on, the battery symbol extinguishes.

Low battery warning

If the battery symbol should change its colour to RED and start flashing when switching
MAXLUPE on or during operation, the batteries need charging immediately. 

Note:

If you disregard the invitation to charge the batteries, MAXLUPE automatically switches off all
functions in battery operation. If you continue working in the mains mode without charging the 

MAXLUPEV40_deu.qxd  10.11.2006  11:42  Seite 49

Summary of Contents for MAXLUPE

Page 1: ...User manual Please read carefully Everything becomes clear MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 32 ...

Page 2: ...UPE V 4 0 to which this declaration refers corresponds with the following standards or normative documents Council Directive 93 42 EEC of 14 June 1993 concerning medical devices Class I Annexe VII The CE conformity marking on this product proves this accordance Alsbach Hähnlein Bernd Reinecker Managing Director Place and date of issue Name and signature MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 33...

Page 3: ... other medical products 38 Instructions for operation and safety 38 Precautionary measures 38 Product life 39 Notes on the electromagnetic compatibility EMV 39 40 Replacing the power supply unit 40 Installation and service 40 Cleaning 40 Classification Type BF 41 Advice for transport and storage 41 Environmental notice 41 MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 34 ...

Page 4: ...witching 44 Adjustment of the lenses 44 Adjustment of the magnification 45 Rear controls 46 ON OFF push button 47 Brightness 47 Freeze image 47 Input socket 12V DC 47 Operation of MAXLUPE 47 Inclinable display 48 Operation on the public mains supply 48 Battery operation 48 MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 35 ...

Page 5: ...0 Stand by function 51 Use of the handwriting stand 52 53 Changing the batteries 54 CE mark 54 Medical device booklet Safety checks 54 Technical Data of MAXLUPE V4 0 55 Product identity 56 Operation and use 57 Maintenance Inspection Repair 58 Safety checks 59 Warranty information 62 Contact MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 36 ...

Page 6: ...d purpose MAXLUPE was conceived to assist visually impaired people with the reading of printed text as well as viewing pictures and photos in full colour Visually impaired people compensate to a certain extent for their deficiency or illness by using this device 3 Mode of operation MAXLUPE is an electronic video magnifier Text or pictures are recorded by an integrated colour camera with a special ...

Page 7: ...opening the unit The device must only be installed and operated in closed and dry rooms Never expose MAXLUPE to direct sunlight Never store the device on the heating Protect the display of MAXLUPE against shocks and scratches Take care that the cable does not cause danger of tripping Point out these dangers to other persons especially children 6 Precautionary measures If technical problems do occu...

Page 8: ...re the use in the indicated environment MAXLUPE operates on HF energy exclusively for its own function Therefore the emitted interference of high frequency disturbances is very low and the possibility of disturbing other appliances operated close by is improbable When operating the system simultaneously with other systems however the possibility of disturbances of the system or other systems shoul...

Page 9: ...f one meter to portable and mobile HF telecommunication devices 9 Replacing the power supply unit Use only the original power supply unit tested according to EN 60601 of Reinecker Reha Technik GmbH as a replacement 10 Installation and service We refer to the user regulations for medical products 11 Cleaning a The system has to be disconnected before cleaning b No liquids must reach the interior of...

Page 10: ...ative humidity 30 to 80 not condensing Air pressure 700 1060 hPa 14 Environmental notice Environmentally friendly disposal according to EC directive 2002 96 EG The system contains electronic components In order to avoid risks or dangers for the environment through non professional disposal the disposal of the product including all accessories has to correspond to the valid directives Ni Mh MAXLUPE...

Page 11: ...trical radiation Carrying case MAXLUPE comes with a carrying case The carrying case has a handle and shoulder strap The integrated spring lock facilitates smooth opening and closing of the carrying case Item list The carrying case contains MAXLUPE with power supply unit and user manual Underneath separated by padding you find the handwriting stand Underneath separated by another padding you find t...

Page 12: ...43 Front controls Colour switching Magnification settings Objective selection switch eading a great experience MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 43 ...

Page 13: ... is equipped with 2 lenses one for reading and one for writing in conjunction with the handwriting stand The appropriate lense is selected by means of the slide switch When pushed to the left MAXLUPE is in reading mode and when pushed to the right the writing mode is selected Select the mode according to your application The lowest magnification is approx x4 in con junction with the handwriting st...

Page 14: ...e altered by turning the magnifica tion wheel in reading as well as in writing mode Magnification range in reading mode approx x4 x16 in colour mode approx x4 x20 in artificial colour mode reading mode With handwriting stand approx x5 x12 in colour and artificial colour mode MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 45 ...

Page 15: ...46 Make reading a g Rear controls Input 12 VDC Freeze image Brightness control ON OFF push button MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 46 ...

Page 16: ...ghtness control you select the luminous intensity of the display background Freeze image With this control you switch the freeze image function on resp off When pressing the freeze image control the contents of the image is saved When switching the freeze image function off you return to the normal display Input socket 12V DC Input socket for supply voltage of power supply unit Operation of MAXLUP...

Page 17: ...art wall socket Place MAXLUPE on the document of your choice a book a magazine or a leaflet Switch on MAXLUPE with the ON OFF switch With the controls brightness magnification and colour selection you have the option to adjust the image according to your individual needs The system of rolls at the underside of MAXLUPE facilitates easy sliding on the document Battery operation MAXLUPE s power suppl...

Page 18: ...cates the state of charge completely full the batteries are fully charged half full the batteries are partly charged and so on Approx 3 seconds after switching the system on the battery symbol extinguishes Low battery warning If the battery symbol should change its colour to RED and start flashing when switching MAXLUPE on or during operation the batteries need charging immediately Note If you dis...

Page 19: ...ins supply via the power supply unit A red LED shows that the docking station is active After use or in between uses place your MAXLUPE on the docking station In this way the batteries are always charged As described you can switch off the functions of MAXLUPE during mains and battery operati on at any time with the ON OFF switch Additionally MAXLUPE offers a standby function in mains as well as i...

Page 20: ...ecognizes that there is no movement and passes over into a sleeping mode after approx two minutes With a movement MAXLUPE is reactivated immediately and you can continue working 2 Automatic switch off If you do not use MAXLUPE for more than approx five minutes all functions switch off completely In order to continue working the system has to be switched on again by pressing the ON OFF push button ...

Page 21: ...h 8 very bright LEDs In this way you are independent of exterior light sources and can use the handwriting stand everywhere Open the brackets completely and place the handwriting stand in a way that the opened brackets point in your direction MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 52 ...

Page 22: ...AXLUPE press the ON OFF switch The illumination of the handwriting stand is activated Place a document underneath the handwriting stand With the controls you adjust optimum display With the wheel for adjusting the magnification you select the magnification optimally suited for you NOTE When you want to return from reading and writing with the handwriting stand to normal operation please don t forg...

Page 23: ...rules 92 31 EEC Medical device booklet 7 MP BetreibV Safety checks Safety checks are only to be done by technicians of Reinecker Reha Technik GmbH or techni cians authorized by the manufacturer Reinecker Reha Technik GmbH does not stipulate dead lines for safety checks The statements made in 6 MP Betreiber Verordnung regarding deadli nes every two years at the latest are recommended Evaluation of ...

Page 24: ... white white black yellow black green black yellow blue Dimensions mm w 162 h 85 d 109 Weight g 980 Power requirements 100 240 VAC 50 60 Hz in conjunction with power supply unit Consumption approx 14 W in conjunction with power supply unit Batteries NI MH 2500mAh Model HR 3u 1 2V Size AA HR6 Battery charging time approx 2 hours Battery operating time approx 2 hours MAXLUPEV40_deu qxd 10 11 2006 11...

Page 25: ...___ Manufacturer Reinecker Reha Technik GmbH Service Number ____________________ Supplier ____________________ Date of delivery ____________________ Supplied by ____________________ Date ____________________ Signature ____________________ Stamp MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 56 ...

Page 26: ... great experience Make reading a g Operation and use 5 Abs 1 MP BetreibV 1 Performance test 2 Instructions Date Manufacturer Supplier Person responsible Initials stamp MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 57 ...

Page 27: ...58 Make reading a g Maintenance Inspection Repair Date Done by Technician company Description of measures Initials stamp MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 58 ...

Page 28: ...59 eading a great experience Safety checks 6 MP BetreibV Date Done by Technician company Result Initials Stamp MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 59 ...

Page 29: ...60 Make reading a g Notizen Notes MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 60 ...

Page 30: ...61 eading a great experience Notizen Notes MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 61 ...

Page 31: ...ating instructions will result in the invalidation of the warranty 4 Interventions from persons other than Reinecker Reha Technik GmbH authorised specialists may lead to invalidity of warranty if the damage is caused by this intervention 5 Batteries are subject to wear and therefore exempt from the warranty 6 In case of repair or touch up the system has to be returned to the manufacturer in Alsbac...

Page 32: ...63 eading a great experience MAXLUPEV40_deu qxd 10 11 2006 11 42 Seite 63 ...

Page 33: ...ax 0365 4305887 gera info gera reineckerreha de www lowvision gera de Low Vision Köpenicker Str 125 10179 Berlin Tel 030 89049780 Fax 030 89049787 berlin info lowvision berlin de www lowvision berlin de Low Vision Aachener Str 1347 1349 50859 Köln Tel 02234 40760 Fax 02234 407625 köln www lowvision koeln de info lowvision koeln de Low Vision Rheinstraße 24 64283 Darmstadt Tel 06151 1596490 Fax 061...