7
3.3
The weld sockets
Connection for ground and electrode cables of Ø16 mm2 and 9mm plug. Maximum current 200A.
Figure: Welding cable connecting sockets
Connections:
Rutile electrodes
"-" Electrode holder
"+" Ground cable
Basic
electrodes
"-" Ground cable
"+"
Electrode
holder
Accessories:
Ground cable Rehm item number
7810107
Electrode cable Rehm item number
7810205
4. Mains connection
The welding unite is equipped with a safety plug.
The unit is operated on fuses or circuit breakers with a rated current of at least 16A. The unit can
be operated with welding power that can trigger a 16A fuse via the thermal melt integral.
The operating status ON is indicated by the power switch on the rear of the unit. BOOSTER2
permanently monitors the mains voltage. If values that are too high (above 255V~) or too low
(below 180V~) are detected during operation, the unit switches off automatically and goes into a
protective function.
Once the mains voltage is correct, working is continued by switching the unit off and on again.