background image

7

3.3  

The weld sockets

Connection for ground and electrode cables of Ø16 mm2 and 9mm plug. Maximum current 200A.

 

   

 

 

 

Figure: Welding cable connecting sockets

Connections:

 

Rutile electrodes 

 

 

 

"-" Electrode holder

 

 

"+" Ground cable

  Basic 

electrodes

 

 

"-" Ground cable

  "+" 

Electrode 

holder 

     

 

Accessories:

 

Ground cable              Rehm item number 

7810107

 

 

Electrode cable           Rehm item number 

7810205

4.  Mains connection

 

The welding unite is equipped with a safety plug.

The unit is operated on fuses or circuit breakers with a rated current of at least 16A. The unit can 

be operated with welding power that can trigger a 16A fuse via the thermal melt integral.

 

The operating status ON is indicated by the power switch on the rear of the unit. BOOSTER2 

permanently monitors the mains voltage. If values that are too high (above 255V~) or too low 

(below 180V~) are detected during operation, the unit switches off automatically and goes into a 

protective function.

Once the mains voltage is correct, working is continued by switching the unit off and on again.

 

Summary of Contents for BOOSTER2 130

Page 1: ...D I E RUS NL PL GB F REHM WELDING TECHNOLOGY BOOSTER2 130 150 SHORT GUIDE...

Page 2: ...http www rehm online de Doc No 730 2441 Date of issue 03 07 2018 The content of this description is the sole property REHM GmbH u Co KG Schwei technik The copying and distribution of this document use...

Page 3: ...ty cycle of 35 25 20 40 C Output current 100 A at a duty cycle of 100 40 C High open circuit voltage of 91V Hot start functionality Continuous electronic mains voltage monitoring range 150V 250Vac Ant...

Page 4: ...lace or hang it up so that the electrode cannot strike and arc whilst in the thermal shutdown phase Alternatively Remove the electrode Caution Non observance may lead to a fire hazard The unit may onl...

Page 5: ...5 3 1 The Rehm control panel The BOOSTER2 is operated via the REHM control panel shown in figure 3 1 Figure Front panel with controls and welding sockets 3 Functional description...

Page 6: ...it it supplies a higher current than the set welding current for a short time to quickly release the short circuit This prevents the BOOSTER2 from dropping out or the electrode sticking during welding...

Page 7: ...d with a safety plug The unit is operated on fuses or circuit breakers with a rated current of at least 16A The unit can be operated with welding power that can trigger a 16A fuse via the thermal melt...

Page 8: ...ocal electric and magnetic fields EMF Welding current generates an electromagnetic field around the welding current circuit and the welding equipment Electromagnetic fields can interfere with some med...

Page 9: ...lding current settings are too high The 1 phase Booster cannot be operated on three phase generators due to the excessive asymmetric load exception special generators for fire brigade use If these uni...

Page 10: ...afety requirements for arc welding units in accordance with the following product standards EN 60 974 1 2013 06 Arc welding equipment Part 1 Welding power source EN 60 974 3 2014 09 Arc welding equipm...