5
6
PRODUCT INTRODUCTION
Control Button
1. Running: Once you plug in the power cable, the air purifier is
in stand-by mode. Press and hold control button for longer
than 3 seconds until you hear a ‘beep’ sound, the air purifier
will be in auto mode, the auto mode icon is on and PM2.5
value is shown on display.
2. Stand by: When the air purifier is running, press and hold
control button for longer than 3 seconds until you hear a
‘beep’ sound, the air purifier will be in stand by mode.
3. Switch mode: Short press on the control button, the air
purifier switch mode among Auto, Low, Medium
,
High and
Night mode and corresponding icon is on.
Auto Mode Icon
In auto mode, the fan speed will be adjusted
automatically depending on the air quality.
The air purifier will switch among Low ( ),
Medium ( ) and High ( ) mode.
Display
PM2.5 Value
PM2.5 (μg/m³) value is shown on the display.
Wi-Fi Status Icon
1. Icon is off - The air purifier Wi-Fi connection is offline
3. Icon flash - The air purifier is waiting for Wi-Fi pairing
4. Icon is on - The air purifier Wi-Fi connection is online
Activated Carbon Filter Status Icon
When the filter lifetime has reached below 30 days, the activated carbon filter status icon will flash red and we
recommend to change the filter. The icon will show constant red color when the lifetime is over.
Particle Filter Status Icon
When the filter lifetime has reached below 30 days, the activated carbon filter status icon will flash red and we
recommend to change the filter. The icon will show constant red color when the lifetime is over.
Night Mode Icon
Once you set up night mode, the air purifier will run at low speed and display is off to provide you with quiet and
comfy sleeping environment.
AIR PURIFIER SET-UP
Preparation
Wi-Fi Reset Button
Open the back door when the air purifier is in
stand-by mode, press and hold the button for
longer than 3 seconds until you hear a ‘beep’
sound, the Wi-Fi status icon will flash. Please
open ‘REHAU HOME’ APP and pair the air purifier
by following instructions on APP.
Activated Carbon Filter Reset Button
When activated carbon filter status icon
flash in red, we suggest you change
the filter. After changing the filter, press
and hold the button for longer than 3
seconds until you hear a ‘beep’ sound
,
the reset process is complete.
Particle Filter Reset Button
When particle filter status icon flash in
red, we suggest you change the filter.
After changing the filter, press and
hold button for longer than 3 seconds
until you hear a ‘beep’ sound
,
the reset
process is complete.
Sensor Module
3. Put the activated carbon filter back to upper side
and put the particle filter back to lower side, plug
in the power cable underneath the back door and
you will hear a ‘beep’ sound. Press and hold the
buttons for longer than 3 seconds until you hear
a ‘beep’ sound, close the back door.
2.
Remove the plastic protection.
1. Open the back door and remove both
filters.
BREATHE2_User_Manual_Print_EN_Rev 05_2018.11.07.indd 5-6
2018/11/8 16:58:46