31
Repeating Incorrect Teaching Processes
If the teaching process failed, the central vacuum
unit‘s LCD display reads „LN01“ for 1 second, follo-
wed by „FAIL“ for 3 seconds.
These two messages can repeat themselves up to 10
times.
1. Wait until the central vacuum unit‘s LCD display
alternately reads „FFB“ and „OPEN“.
2. Repeat the transmitter teaching process (see above).
Make sure the approx. 1 m gap as well as the repeti-
tion time of 60 seconds are not exceeded.
1. Hold the handle of the suction hose or the manual
transmitter against the central vacuum unit (refer to
Fig. 8).
2. Press either the ON or OFF button.
The LCD display on the central vacuum unit displays
the term, „LERN“ = „TEACH“ in English.
3. Move the handle/transmitter approx. 1 m away from
the central vacuum unit and press once again either
the ON or OFF button within 60 seconds.
The LCD display on the central vacuum unit then
changes to „LN01“ for 1 second.
If the teaching step was successful, the display then
reads „OK“ for 3 seconds after „LN01“ goes off.
4. Wait until the „OK“ display goes off.
The transmitter has now been successfully taught
and the central vacuum unit can be started with the
ON button.
Teaching the Transmitters
Fig. 8 Transmitter teaching
DE
EN
Repeating the Deletion Processes
If the deletion process was unsuccessful, the central
vacuum unit‘s LCD display will read “CLR“ for 1
second, followed by “FAIL“ for 3 seconds.
These two messages can repeat themselves up to 10
times.
1. Wait until the operating hours are displayed on the
central vacuum unit‘s LCD display.
2. Briefly press either the ON or OFF button.
3. Try to delete the transmitter again.
Make sure the handle/manual transmitter remains
against the central vacuum unit‘s housing and that
the OFF button is pressed and held down for 5
seconds.
1. Hold the suction hose handle or the manual trans-
mitter against the central vacuum unit (refer to
Fig.
8).
2. Press and hold down the OFF button for 5 seconds
without
moving the transmitter away from the
central vacuum unit.
If the deletion process was successful, the following
appear on the central vacuum unit‘s LCD display:
- “LERN“ (“TEACH“ in English) for 2 seconds;
- “CLR“ for 3 seconds;
- “OK“ for 2 seconds;
- Alternating “FFB“ and “OPEN“.
3. Reteach the transmitter if desired.
Deleting Stored Transmitter Information
Deleting the information on a single transmitter will
cause the information on
all
taught transmitters and
repeaters to be deleted.