20
REGULUS - STDC E Controller - www.regulus.eu
F 4 - Operating modes
In menu
„4. Operating modes”
the controller can
either be switched to automatic mode, switched off, or
switched to a manual operating mode.
The menu is closed by pressing
„esc”
or selecting
„Exit operating modes”
.
F 4.1 - Automatic
Automatic mode is the normal operating mode of the controller. Only automatic mode provides proper
controller function taking into account the current temperatures and the parameters that have been set! After
an interruption of the mains voltage the controller automatically returns to the last operating mode selected!
F 4.2 - Manual
The relay and thus the connected consumer are switched on and off by pressing a key, with no regard to the
current temperatures and the parameters which have been set. The measured temperatures are also shown.
When operating mode
„Manual”
is activated, the current temperatures and the selected
parameters are no longer considered. There is a danger of scalding or serious damage to the
system. The operating mode
„Manual”
may only be used by specialists for brief function tests or
during commissioning!
F 4.3 - Off
When the operating mode
„Off”
is activated, all controller functions are switched off. This can lead,
for example, to overheating on the solar collector or other system components. The measured
temperatures continue to be shown to provide an overview.
F 4.4 -
Not in use
Danger
Danger